Vulnerabilites related to siemens - simatic_easie_pcs_7_skill
Vulnerability from fkie_nvd
Published
2021-12-14 12:15
Modified
2024-11-21 06:27
Severity ?
Summary
A vulnerability has been identified in SIMATIC eaSie PCS 7 Skill Package (All versions < V21.00 SP3). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by default.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_easie_pcs_7_skill | * | |
siemens | simatic_easie_pcs_7_skill | 21.00 | |
siemens | simatic_easie_pcs_7_skill | 21.00 | |
siemens | simatic_easie_pcs_7_skill | 21.00 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_easie_pcs_7_skill:*:*:*:*:*:*:*:*", "matchCriteriaId": "807320F9-B93D-45EC-AAAC-D566FAA4A40F", "versionEndIncluding": "20.07", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_easie_pcs_7_skill:21.00:-:*:*:*:*:*:*", "matchCriteriaId": "CC06A7C9-7A87-4CBF-B6DB-80475A0F0756", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_easie_pcs_7_skill:21.00:sp1:*:*:*:*:*:*", "matchCriteriaId": "425EFA36-DBC0-493E-886E-2A0042A5698C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_easie_pcs_7_skill:21.00:sp2:*:*:*:*:*:*", "matchCriteriaId": "9D207813-7AF3-4F97-85DC-ECB650075A44", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC eaSie PCS 7 Skill Package (All versions \u003c V21.00 SP3). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by default." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC eaSie PCS 7 Skill Package (Todas las versiones anteriores a V21.00 SP3). Al descargar archivos, los sistemas afectados no neutralizan correctamente los elementos especiales dentro del nombre de la ruta. Un atacante podr\u00eda entonces hacer que el nombre de ruta sea resuelto en una ubicaci\u00f3n fuera del directorio restringido en el servidor y leer archivos cr\u00edticos inesperados. La funci\u00f3n de descarga de archivos afectada est\u00e1 deshabilitada por defecto" } ], "id": "CVE-2021-42022", "lastModified": "2024-11-21T06:27:06.027", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-14T12:15:09.863", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
CVE-2021-42022 (GCVE-0-2021-42022)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 03:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A vulnerability has been identified in SIMATIC eaSie PCS 7 Skill Package (All versions < V21.00 SP3). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by default.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SIMATIC eaSie PCS 7 Skill Package |
Version: All versions < V21.00 SP3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:22:25.755Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC eaSie PCS 7 Skill Package", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V21.00 SP3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC eaSie PCS 7 Skill Package (All versions \u003c V21.00 SP3). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by default." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-14T12:06:37", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-42022", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC eaSie PCS 7 Skill Package", "version": { "version_data": [ { "version_value": "All versions \u003c V21.00 SP3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC eaSie PCS 7 Skill Package (All versions \u003c V21.00 SP3). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by default." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-42022", "datePublished": "2021-12-14T12:06:37", "dateReserved": "2021-10-06T00:00:00", "dateUpdated": "2024-08-04T03:22:25.755Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }