Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7_1200_cpu_firmware | * | |
siemens | simatic_s7_1200_cpu | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7_1200_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5876D57A-A65A-4968-BDDA-EAA7EEB8BFCB", "versionEndIncluding": "4.1.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7_1200_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "79270F18-B58F-4F16-ACAD-297AE91F27EB", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors." }, { "lang": "es", "value": "Vulnerabilidad de CSRF en el servidor web en dispositivos Siemens SIMATIC S7-1200 CPU con firmware en versiones anteriores a 4.1.3, permite a atacantes remotos secuestrar la autenticaci\u00f3n de v\u00edctimas no especificadas a trav\u00e9s de vectores no especificados." } ], "id": "CVE-2015-5698", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2015-08-30T14:59:03.313", "references": [ { "source": "cve@mitre.org", "url": "http://packetstormsecurity.com/files/172315/Siemens-SIMATIC-S7-1200-Cross-Site-Request-Forgery.html" }, { "source": "cve@mitre.org", "url": "http://www.securitytracker.com/id/1033419" }, { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-134003.pdf" }, { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134003.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-239-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://packetstormsecurity.com/files/172315/Siemens-SIMATIC-S7-1200-Cross-Site-Request-Forgery.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securitytracker.com/id/1033419" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-134003.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134003.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-239-02" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2016-03-16 10:59
Modified
2025-04-12 10:46
Severity ?
Summary
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7_1200_cpu | - | |
siemens | simatic_s7_cpu_1200_firmware | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7_1200_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "79270F18-B58F-4F16-ACAD-297AE91F27EB", "vulnerable": false } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7_cpu_1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BCF4722-1850-48CD-9BCA-6EBD9EFF8147", "versionEndIncluding": "3.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a \"user program block\" protection mechanism via unspecified vectors." }, { "lang": "es", "value": "Dispositivos Siemens SIMATIC S7-1200 CPU en versiones anteriores a 4.0 permiten a atancantes remotos eludir un mecanismo de protecci\u00f3n de \"bloqueo de programa de usuario\" a trav\u00e9s de vectores no especificados." } ], "id": "CVE-2016-2846", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-03-16T10:59:04.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf" }, { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf" }, { "source": "cve@mitre.org", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-254" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2015-01-21 17:59
Modified
2025-04-12 10:46
Severity ?
Summary
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7_1200_cpu_firmware | * | |
siemens | simatic_s7_1200_cpu | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7_1200_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "755D96DF-3F53-474A-A960-74CF5CD9F5D5", "versionEndIncluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7_1200_cpu:*:*:*:*:*:*:*:*", "matchCriteriaId": "C45C175C-98B5-4BFA-AF85-5AFE63881681", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors." }, { "lang": "es", "value": "Vulnerabilidad de la redirecci\u00f3n abierta en el servidor web integrado en los dispositivos Siemens SIMATIC S7-1200 CPU con firmware anterior a 4.1 permite a atacantes remotos redirigir usuarios a sitios web arbitrarios ay realizar ataques de phishing a trav\u00e9s de vectores no especifcados." } ], "evaluatorComment": "\u003ca href=\"http://cwe.mitre.org/data/definitions/601.html\"\u003eCWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)\u003c/a\u003e", "id": "CVE-2015-1048", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2015-01-21T17:59:02.293", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-597212.pdf" }, { "source": "cve@mitre.org", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597212.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-597212.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597212.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2015-1048 (GCVE-0-2015-1048)
Vulnerability from cvelistv5
Published
2015-01-21 17:00
Modified
2024-08-06 04:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T04:33:19.309Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-597212.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597212.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2015-01-21T00:00:00", "descriptions": [ { "lang": "en", "value": "Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-10T14:06:10", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-597212.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597212.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2015-1048", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-597212.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-597212.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-597212.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-597212.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2015-1048", "datePublished": "2015-01-21T17:00:00", "dateReserved": "2015-01-12T00:00:00", "dateUpdated": "2024-08-06T04:33:19.309Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2016-2846 (GCVE-0-2016-2846)
Vulnerability from cvelistv5
Published
2016-03-16 10:00
Modified
2024-08-05 23:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T23:32:21.339Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2016-03-14T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a \"user program block\" protection mechanism via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-10T14:06:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-2846", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a \"user program block\" protection mechanism via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-833048.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-075-01" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-833048.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-2846", "datePublished": "2016-03-16T10:00:00", "dateReserved": "2016-03-06T00:00:00", "dateUpdated": "2024-08-05T23:32:21.339Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2015-5698 (GCVE-0-2015-5698)
Vulnerability from cvelistv5
Published
2015-08-30 00:00
Modified
2024-08-06 06:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T06:59:03.900Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1033419", "tags": [ "vdb-entry", "x_transferred" ], "url": "http://www.securitytracker.com/id/1033419" }, { "tags": [ "x_transferred" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-134003.pdf" }, { "tags": [ "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-239-02" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134003.pdf" }, { "tags": [ "x_transferred" ], "url": "http://packetstormsecurity.com/files/172315/Siemens-SIMATIC-S7-1200-Cross-Site-Request-Forgery.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2015-08-27T00:00:00", "descriptions": [ { "lang": "en", "value": "Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-15T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "name": "1033419", "tags": [ "vdb-entry" ], "url": "http://www.securitytracker.com/id/1033419" }, { "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-134003.pdf" }, { "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-239-02" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134003.pdf" }, { "url": "http://packetstormsecurity.com/files/172315/Siemens-SIMATIC-S7-1200-Cross-Site-Request-Forgery.html" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2015-5698", "datePublished": "2015-08-30T00:00:00", "dateReserved": "2015-07-29T00:00:00", "dateUpdated": "2024-08-06T06:59:03.900Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }