Vulnerabilites related to siemens - siveillance_video_management_software_2019_r1
CVE-2021-42021 (GCVE-0-2021-42021)
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 03:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-26 - Path Traversal: '/dir/../filename'
Summary
A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | Siveillance Video DLNA Server |
Version: 2019 R1 |
|||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T03:22:25.972Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2019 R1" } ] }, { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2019 R2" } ] }, { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2019 R3" } ] }, { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2020 R1" } ] }, { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2020 R2" } ] }, { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2020 R3" } ] }, { "product": "Siveillance Video DLNA Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "2021 R1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application\u2019s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-26", "description": "CWE-26: Path Traversal: \u0027/dir/../filename\u0027", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-09T11:32:15", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-42021", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2019 R1" } ] } }, { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2019 R2" } ] } }, { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2019 R3" } ] } }, { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2020 R1" } ] } }, { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2020 R2" } ] } }, { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2020 R3" } ] } }, { "product_name": "Siveillance Video DLNA Server", "version": { "version_data": [ { "version_value": "2021 R1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application\u2019s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-26: Path Traversal: \u0027/dir/../filename\u0027" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-42021", "datePublished": "2021-11-09T11:32:15", "dateReserved": "2021-10-06T00:00:00", "dateUpdated": "2024-08-04T03:22:25.972Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6582 (GCVE-0-2019-6582)
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Siveillance VMS 2017 R2 |
Version: All versions < V11.2a |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.276Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance VMS 2017 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2a" } ] }, { "product": "Siveillance VMS 2018 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.1a" } ] }, { "product": "Siveillance VMS 2018 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.2a" } ] }, { "product": "Siveillance VMS 2018 R3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.3a" } ] }, { "product": "Siveillance VMS 2019 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285: Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-06-14T14:07:32", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6582", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance VMS 2017 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V11.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V12.1a" } ] } }, { "product_name": "Siveillance VMS 2018 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V12.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R3", "version": { "version_data": [ { "version_value": "All versions \u003c V12.3a" } ] } }, { "product_name": "Siveillance VMS 2019 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1a" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285: Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6582", "datePublished": "2019-06-12T13:47:57", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.276Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6581 (GCVE-0-2019-6581)
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Siveillance VMS 2017 R2 |
Version: All versions < V11.2a |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.105Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance VMS 2017 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2a" } ] }, { "product": "Siveillance VMS 2018 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.1a" } ] }, { "product": "Siveillance VMS 2018 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.2a" } ] }, { "product": "Siveillance VMS 2018 R3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.3a" } ] }, { "product": "Siveillance VMS 2019 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285: Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-06-14T14:07:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6581", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance VMS 2017 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V11.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V12.1a" } ] } }, { "product_name": "Siveillance VMS 2018 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V12.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R3", "version": { "version_data": [ { "version_value": "All versions \u003c V12.3a" } ] } }, { "product_name": "Siveillance VMS 2019 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1a" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285: Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6581", "datePublished": "2019-06-12T13:47:57", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.105Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6580 (GCVE-0-2019-6580)
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-862 - Missing Authorization
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Siveillance VMS 2017 R2 |
Version: All versions < V11.2a |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.107Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance VMS 2017 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2a" } ] }, { "product": "Siveillance VMS 2018 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.1a" } ] }, { "product": "Siveillance VMS 2018 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.2a" } ] }, { "product": "Siveillance VMS 2018 R3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.3a" } ] }, { "product": "Siveillance VMS 2019 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-862", "description": "CWE-862: Missing Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-06-14T14:06:47", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6580", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance VMS 2017 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V11.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V12.1a" } ] } }, { "product_name": "Siveillance VMS 2018 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V12.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R3", "version": { "version_data": [ { "version_value": "All versions \u003c V12.3a" } ] } }, { "product_name": "Siveillance VMS 2019 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1a" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-862: Missing Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6580", "datePublished": "2019-06-12T13:47:57", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.107Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2019-06-12 14:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▶ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2017_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "57B38507-984D-40E9-A3A5-40B7BF29BDF7", "versionEndExcluding": "11.2a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "323A9152-90F1-4222-8468-1C1843B30C21", "versionEndExcluding": "12.1a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA4F90DF-54F4-4757-BFBB-D3594B866B45", "versionEndExcluding": "12.2a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r3:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDA10332-9542-4C47-9870-BADDC276C160", "versionEndExcluding": "12.3a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A8464AB-5EC6-4147-90B2-19ED8FB3A4E4", "versionEndExcluding": "13.1a", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Siveillance VMS 2017 R2 (todas las versiones anteriores a la V11.2a), Siveillance VMS 2018 R1 (todas las versiones anteriores a la V12.1a), Siveillance VMS 2018 R2 (todas las versiones anteriores a la V12.2a), Siveillance VMS 2018 R3 (todas las versiones anteriores a la V12.3a), Siveillance VMS 2019 R1 (todas las versiones anteriores a la V13.1a). Un atacante con acceso de red al puerto 80 / TCP puede cambiar las propiedades de eventos definidas por el usuario sin la debida autorizaci\u00f3n. La vulnerabilidad de la seguridad podr\u00eda ser explotada por un atacante autenticado con acceso de red al servicio afectado. No se requiere la interacci\u00f3n del usuario para explotar esta vulnerabilidad de seguridad. La explotaci\u00f3n con \u00e9xito compromete la integridad de las propiedades de eventos definidas por el usuario y la disponibilidad de la funcionalidad correspondiente. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "id": "CVE-2019-6582", "lastModified": "2024-11-21T04:46:44.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 4.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-06-12T14:29:06.087", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-285" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-863" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-11-09 12:15
Modified
2024-11-21 06:27
Severity ?
Summary
A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application’s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks.
References
▶ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf | Patch, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf | Patch, Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "3922D1E1-35A6-46F9-83B8-9E57CD1AA47B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "7584896C-E932-4A5E-8045-04D4262A9E2B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r3:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E1D3534-ADC0-43F1-8270-F09696195754", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2020_r1:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFC80AF3-17E5-4535-94FB-3B43C32BF8D8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2020_r2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2323FB89-9DAF-4AA8-BFDB-60CA31EEE760", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siveillance_video_dlna_server:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E210B89-066A-447B-8379-F8C857F56A70", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). The affected application contains a path traversal vulnerability that could allow to read arbitrary files on the server that are outside the application\u2019s web document directory. An unauthenticated remote attacker could exploit this issue to access sensitive information for subsequent attacks." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Siveillance Video DLNA Server (2019 R1), Siveillance Video DLNA Server (2019 R2), Siveillance Video DLNA Server (2019 R3), Siveillance Video DLNA Server (2020 R1), Siveillance Video DLNA Server (2020 R2), Siveillance Video DLNA Server (2020 R3), Siveillance Video DLNA Server (2021 R1). La aplicaci\u00f3n afectada contiene una vulnerabilidad de salto de ruta que podr\u00eda permitir la lectura de archivos arbitrarios en el servidor que est\u00e1n fuera del directorio del documento web de la aplicaci\u00f3n. Un atacante remoto no autenticado podr\u00eda explotar este problema para acceder a informaci\u00f3n confidencial para posteriores ataques" } ], "id": "CVE-2021-42021", "lastModified": "2024-11-21T06:27:05.887", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-11-09T12:15:10.523", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-26" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-06-12 14:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▶ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2017_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "57B38507-984D-40E9-A3A5-40B7BF29BDF7", "versionEndExcluding": "11.2a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "323A9152-90F1-4222-8468-1C1843B30C21", "versionEndExcluding": "12.1a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA4F90DF-54F4-4757-BFBB-D3594B866B45", "versionEndExcluding": "12.2a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r3:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDA10332-9542-4C47-9870-BADDC276C160", "versionEndExcluding": "12.3a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A8464AB-5EC6-4147-90B2-19ED8FB3A4E4", "versionEndExcluding": "13.1a", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Siveillance VMS 2017 R2 (todas las versiones anteriores a la V11.2a), Siveillance VMS 2018 R1 (todas las versiones anteriores a la V12.1a), Siveillance VMS 2018 R2 (todas las versiones anteriores a la V12.2a), Siveillance VMS 2018 R3 (todas las versiones anteriores a la V12.3a), Siveillance VMS 2019 R1 (todas las versiones anteriores a la V13.1a). Un atacante con acceso de red al puerto 80 / TCP podr\u00eda cambiar los roles de los usuarios sin la debida autorizaci\u00f3n. La vulnerabilidad de la seguridad podr\u00eda ser explotada por un atacante autenticado con acceso de red al servicio afectado. No se requiere la interacci\u00f3n del usuario para explotar esta vulnerabilidad de seguridad. La explotaci\u00f3n con \u00e9xito compromete la confidencialidad, integridad y disponibilidad del sistema objetivo. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "id": "CVE-2019-6581", "lastModified": "2024-11-21T04:46:44.800", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-06-12T14:29:06.057", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-285" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-06-12 14:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▶ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2017_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "57B38507-984D-40E9-A3A5-40B7BF29BDF7", "versionEndExcluding": "11.2a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "323A9152-90F1-4222-8468-1C1843B30C21", "versionEndExcluding": "12.1a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r2:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA4F90DF-54F4-4757-BFBB-D3594B866B45", "versionEndExcluding": "12.2a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2018_r3:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDA10332-9542-4C47-9870-BADDC276C160", "versionEndExcluding": "12.3a", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:siveillance_video_management_software_2019_r1:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A8464AB-5EC6-4147-90B2-19ED8FB3A4E4", "versionEndExcluding": "13.1a", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Siveillance VMS 2017 R2 (todas las versiones anteriores a la V11.2a), Siveillance VMS 2018 R1 (todas las versiones anteriores a la V12.1a), Siveillance VMS 2018 R2 (todas las versiones anteriores a la V12.2a), Siveillance VMS 2018 R3 (todas las versiones anteriores a la V12.3a), Siveillance VMS 2019 R1 (todas las versiones anteriores a la V13.1a). Un atacante con acceso de red al puerto 80 / TCP podr\u00eda cambiar las propiedades del dispositivo sin autorizaci\u00f3n. No se requiere la interacci\u00f3n del usuario para explotar esta vulnerabilidad de seguridad. La explotaci\u00f3n con \u00e9xito compromete la confidencialidad, integridad y disponibilidad del sistema objetivo. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad." } ], "id": "CVE-2019-6580", "lastModified": "2024-11-21T04:46:44.670", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-06-12T14:29:06.010", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-862" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-862" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }