Vulnerabilites related to hitachienergy - sys600
CVE-2018-1168 (GCVE-0-2018-1168)
Vulnerability from cvelistv5
Published
2018-02-21 14:00
Modified
2024-08-05 03:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - -Improper Access Control
Summary
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
ABB | ABB MicroSCADA |
Version: 9.3 with FP 1-2-3 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T03:51:48.990Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-141" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ABB MicroSCADA", "vendor": "ABB", "versions": [ { "status": "affected", "version": "9.3 with FP 1-2-3" } ] } ], "datePublic": "2018-02-03T00:00:00", "descriptions": [ { "lang": "en", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284-Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-02-21T13:57:01", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC" }, { "tags": [ "x_refsource_MISC" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-141" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "zdi-disclosures@trendmicro.com", "ID": "CVE-2018-1168", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ABB MicroSCADA", "version": { "version_data": [ { "version_value": "9.3 with FP 1-2-3" } ] } } ] }, "vendor_name": "ABB" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284-Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC", "refsource": "CONFIRM", "url": "https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC" }, { "name": "https://zerodayinitiative.com/advisories/ZDI-18-141", "refsource": "MISC", "url": "https://zerodayinitiative.com/advisories/ZDI-18-141" } ] } } } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2018-1168", "datePublished": "2018-02-21T14:00:00", "dateReserved": "2017-12-05T00:00:00", "dateUpdated": "2024-08-05T03:51:48.990Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-1778 (GCVE-0-2022-1778)
Vulnerability from cvelistv5
Published
2022-09-14 17:05
Modified
2025-06-04 15:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hitachi Energy | MicroSCADA X SYS600 |
Version: 10 Version: 10.1 Version: 10.1.1 Version: 10.2 Version: 10.2.1 Version: 10.3 Version: 10.3.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:17:00.365Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-1778", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-04T15:05:31.988579Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-04T15:05:54.743Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10" }, { "status": "affected", "version": "10.1" }, { "status": "affected", "version": "10.1.1" }, { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] } ], "datePublic": "2022-09-05T22:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eImproper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\u003c/p\u003e" } ], "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-25T11:01:22.019Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106\u0026languageCode=en\u0026Preview=true" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eRemediated in SYS600 10.4 \u003c/p\u003e\u003cp\u003eUpdate to at least SYS600 version 10.4.\u003c/p\u003e" } ], "value": "Remediated in SYS600 10.4 \n\nUpdate to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by ...", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eApply general mitigation factors as specify in the advisory.\u003c/p\u003e" } ], "value": "Apply general mitigation factors as specify in the advisory." } ], "x_ConverterErrors": { "TITLE": { "error": "TITLE too long. Truncating in v5 record.", "message": "Truncated!" } }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-1778", "STATE": "PUBLIC", "TITLE": "A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by an administrator access." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-1778", "datePublished": "2022-09-14T17:05:36.801Z", "dateReserved": "2022-05-18T00:00:00.000Z", "dateUpdated": "2025-06-04T15:05:54.743Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-2277 (GCVE-0-2022-2277)
Vulnerability from cvelistv5
Published
2022-09-14 17:02
Modified
2025-06-04 15:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Summary
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hitachi Energy | MicroSCADA X SYS600 |
Version: 10.2 Version: 10.2.1 Version: 10.3 Version: 10.3.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:32:09.384Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-2277", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-04T15:06:46.857674Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-04T15:06:49.732Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] } ], "datePublic": "2022-09-05T22:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eImproper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600\u0027s ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\u003c/p\u003e" } ], "value": "Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600\u0027s ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1284", "description": "CWE-1284 Improper Validation of Specified Quantity in Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-25T11:06:59.557Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eRemediated in SYS600 10.4 \u003c/p\u003e\u003cp\u003eUpdate to at least SYS600 version 10.4.\u003c/p\u003e" } ], "value": "Remediated in SYS600 10.4 \n\nUpdate to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation flaw in the process that establishes the ICCP communication. The validation flaw will cause a denial-of-service when ICCP of SYS600 is request to forward any da ...", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eDo not enable ICCP if it is not used. \u003c/p\u003e\u003cp\u003eApply general mitigation factors as specify in the advisory.\u003c/p\u003e" } ], "value": "Do not enable ICCP if it is not used. \n\nApply general mitigation factors as specify in the advisory." } ], "x_ConverterErrors": { "TITLE": { "error": "TITLE too long. Truncating in v5 record.", "message": "Truncated!" } }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-2277", "STATE": "PUBLIC", "TITLE": "A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation flaw in the process that establishes the ICCP communication. The validation flaw will cause a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600\u0027s ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Do not enable ICCP if it is not used. Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-2277", "datePublished": "2022-09-14T17:02:01.251Z", "dateReserved": "2022-07-01T00:00:00.000Z", "dateUpdated": "2025-06-04T15:06:49.732Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-29490 (GCVE-0-2022-29490)
Vulnerability from cvelistv5
Published
2022-09-12 19:24
Modified
2024-09-17 03:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hitachi Energy | MicroSCADA X SYS600 |
Version: 10 Version: 10.1 Version: 10.1.1 Version: 10.2 Version: 10.2.1 Version: 10.3 Version: 10.3.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:26:05.933Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10" }, { "status": "affected", "version": "10.1" }, { "status": "affected", "version": "10.1.1" }, { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] } ], "datePublic": "2022-09-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285 Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-12T19:24:03", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nUpdate to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists in the Workplace X WebUI in which an authenticated user is able to execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role.", "workarounds": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-29490", "STATE": "PUBLIC", "TITLE": "A vulnerability exists in the Workplace X WebUI in which an authenticated user is able to execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285 Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nUpdate to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-29490", "datePublished": "2022-09-12T19:24:03.558026Z", "dateReserved": "2022-04-29T00:00:00", "dateUpdated": "2024-09-17T03:37:32.417Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-3353 (GCVE-0-2022-3353)
Vulnerability from cvelistv5
Published
2023-02-21 13:50
Modified
2025-03-12 15:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-404 - Improper Resource Shutdown or Release
Summary
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.
An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.
Already existing/established client-server connections are not affected.
List of affected CPEs:
* cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Hitachi Energy | FOX61x TEGO1 |
Version: tego1_r15b08 Version: tego1_r2a16_03 Version: tego1_r2a16 Version: tego1_r1e01 Version: tego1_r1d02 Version: tego1_r1c07 Version: tego1_r1b02 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T01:07:06.451Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-3353", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-12T15:16:44.962103Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-12T15:17:11.275Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FOX61x TEGO1", "vendor": "Hitachi Energy", "versions": [ { "status": "unaffected", "version": "tego1_r16a11" }, { "status": "affected", "version": "tego1_r15b08" }, { "status": "affected", "version": "tego1_r2a16_03" }, { "status": "affected", "version": "tego1_r2a16" }, { "status": "affected", "version": "tego1_r1e01" }, { "status": "affected", "version": "tego1_r1d02" }, { "status": "affected", "version": "tego1_r1c07" }, { "status": "affected", "version": "tego1_r1b02" } ] }, { "defaultStatus": "unaffected", "product": "GMS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "GMS600 1.3" } ] }, { "defaultStatus": "unaffected", "product": "ITT600 SA Explorer", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "ITT600 SA Explorer 1.1.0" }, { "status": "affected", "version": "ITT600 SA Explorer 1.1.1" }, { "status": "affected", "version": "ITT600 SA Explorer 1.1.2" }, { "status": "affected", "version": "ITT600 SA Explorer 1.5.0" }, { "status": "affected", "version": "ITT600 SA Explorer 1.5.1" }, { "status": "affected", "version": "ITT600 SA Explorer 1.6.0" }, { "status": "affected", "version": "ITT600 SA Explorer 1.6.0.1" }, { "status": "affected", "version": "ITT600 SA Explorer 1.7.0" }, { "status": "affected", "version": "ITT600 SA Explorer 1.7.2" }, { "status": "affected", "version": "ITT600 SA Explorer 1.8.0" }, { "status": "affected", "version": "ITT600 SA Explorer 2.0.1" }, { "status": "affected", "version": "ITT600 SA Explorer 2.0.2" }, { "status": "affected", "version": "ITT600 SA Explorer 2.0.3" }, { "status": "affected", "version": "ITT600 SA Explorer 2.0.4.1" }, { "status": "affected", "version": "ITT600 SA Explorer 2.0.5.0" }, { "status": "affected", "version": "ITT600 SA Explorer 2.0.5.4" }, { "status": "affected", "version": "ITT600 SA Explorer 2.1.0.4" }, { "status": "affected", "version": "ITT600 SA Explorer 2.1.0.5" }, { "status": "unaffected", "version": "ITT600 SA Explorer 2.1.1.2" } ] }, { "defaultStatus": "unaffected", "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "SYS600 10" }, { "status": "affected", "version": "SYS600 10.1" }, { "status": "affected", "version": "SYS600 10.1.1" }, { "status": "affected", "version": "SYS600 10.2" }, { "status": "affected", "version": "SYS600 10.2.1" }, { "status": "affected", "version": "SYS600 10.3" }, { "status": "affected", "version": "SYS600 10.3.1" }, { "status": "affected", "version": "SYS600 10.4" }, { "status": "unaffected", "version": "SYS600 10.4.1" } ] }, { "defaultStatus": "unaffected", "product": "MSM", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "MSM 2.2.3;0" } ] }, { "defaultStatus": "unaffected", "product": "PWC600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "PWC600 1.0" }, { "status": "affected", "version": "PWC600 1.1" }, { "status": "affected", "version": "PWC600 1.2" } ] }, { "defaultStatus": "unaffected", "product": "REB500", "vendor": "Hitachi Energy", "versions": [ { "lessThan": "7.*", "status": "affected", "version": "REB500 7.0", "versionType": "7.*" }, { "lessThan": "8.*", "status": "affected", "version": "REB500 8.0", "versionType": "8.*" }, { "status": "unaffected", "version": "REB500 8.3.3.0" } ] }, { "defaultStatus": "unaffected", "product": "Relion\u00ae 670", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "Relion 670 1.2" }, { "status": "affected", "version": "Relion 670 2.0" }, { "status": "affected", "version": "Relion 670 version 2.1" }, { "status": "affected", "version": "Relion 670 2.2.0" }, { "status": "affected", "version": "Relion 670 2.2.1" }, { "status": "affected", "version": "Relion 670 2.2.2" }, { "status": "affected", "version": "Relion 670 2.2.3" }, { "status": "affected", "version": "Relion 670 2.2.4" }, { "status": "affected", "version": "Relion 670 2.2.5" } ] }, { "defaultStatus": "unaffected", "product": "Relion\u00ae 650", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "Relion 650 1.1" }, { "status": "affected", "version": "Relion 650 1.3" }, { "status": "affected", "version": "Relion 650 2.1" }, { "status": "affected", "version": "Relion 650 2.2.0" }, { "status": "affected", "version": "Relion 650 2.2.1" }, { "status": "affected", "version": "Relion 650 2.2.2" }, { "status": "affected", "version": "Relion 650 2.2.3" }, { "status": "affected", "version": "Relion 650 2.2.4" }, { "status": "affected", "version": "Relion 650 2.2.5" } ] }, { "defaultStatus": "unaffected", "product": "SAM600-IO", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "Relion SAM600-IO 2.2.1" }, { "status": "affected", "version": "Relion SAM600-IO 2.2.5" } ] }, { "defaultStatus": "unaffected", "product": "RTU500", "vendor": "Hitachi Energy", "versions": [ { "lessThanOrEqual": "12.0.14", "status": "affected", "version": "RTU500 12.0.1", "versionType": "12.0.14" }, { "status": "unaffected", "version": "RTU500 12.0.15" }, { "lessThanOrEqual": "12.2.11", "status": "affected", "version": "RTU500 12.2.1", "versionType": "12.2.11" }, { "status": "unaffected", "version": "RTU500 12.2.12" }, { "lessThanOrEqual": "12.4.11", "status": "affected", "version": "RTU500 12.4.1", "versionType": "12.4.11" }, { "status": "unaffected", "version": "RTU500 12.4.12" }, { "lessThanOrEqual": "12.6.8", "status": "affected", "version": "RTU500 12.6.1", "versionType": "12.6.8" }, { "status": "unaffected", "version": "RTU500 12.6.9" }, { "lessThanOrEqual": "12.7.4", "status": "affected", "version": "RTU500 12.7.1", "versionType": "12.7.4" }, { "status": "unaffected", "version": "RTU500 12.7.5" }, { "lessThanOrEqual": "13.2.5", "status": "affected", "version": "RTU500 13.2.1", "versionType": "13.2.5" }, { "status": "unaffected", "version": "RTU500 13.2.6" }, { "lessThanOrEqual": "13.3.3", "status": "affected", "version": "RTU500 13.3.1", "versionType": "13.3.3" }, { "status": "unaffected", "version": "RTU500 13.3.4" }, { "status": "affected", "version": "RTU500 13.4.1" }, { "status": "unaffected", "version": "RTU500 13.4.2" } ] }, { "defaultStatus": "unaffected", "product": "TXpert Hub CoreTec 4", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "CoreTec 4 version 2.0.*" }, { "status": "affected", "version": "CoreTec 4 version 2.1.*" }, { "status": "affected", "version": "CoreTec 4 version 2.2.*" }, { "status": "affected", "version": "CoreTec 4 version 2.3.*" }, { "status": "affected", "version": "CoreTec 4 version 2.4.*" }, { "status": "affected", "version": "CoreTec 4 version 3.0.*" } ] }, { "defaultStatus": "unaffected", "product": "TXpert Hub CoreTec 5", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "CoreTec 5 version 3.0.*" } ] } ], "datePublic": "2023-02-14T13:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\n\u003cdiv\u003e\u003cp\u003eA vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.\u0026nbsp;\u003c/p\u003e\u003cp\u003eAn attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.\u0026nbsp;\u003cbr\u003e\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eAlready existing/established client-server connections are not affected.\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\n\n\u003c/p\u003e\u003cdiv\u003e\u003cp\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eList of affected CPEs:\u003c/span\u003e\u003cbr\u003e\u003c/p\u003e\u003c/div\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003ecpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e\u003c/div\u003e" } ], "value": "\n\n\nA vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.\u00a0\n\nAn attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.\u00a0\n\n\n\n\nAlready existing/established client-server connections are not affected.\n\n\n\n\n\nList of affected CPEs:\n\n\n\n\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*\n\n\n\n\n\n\n" } ], "impacts": [ { "capecId": "CAPEC-130", "descriptions": [ { "lang": "en", "value": "CAPEC-130 Excessive Allocation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-404", "description": "CWE-404 Improper Resource Shutdown or Release", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-21T14:09:25.358Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nUpgrade the system once remediated version is available.\n\n\n\u003cbr\u003e" } ], "value": "\nUpgrade the system once remediated version is available.\n\n\n\n" } ], "source": { "discovery": "INTERNAL" }, "title": "IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nRecommended security practices and firewall configurations can help protect a process control network from \nattacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and \nare separated from other networks by means of a firewall system that has a minimal number of ports exposed, \nand others that have to be evaluated case by case. Process control systems should not be used for Internet \nsurfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be \ncarefully scanned for viruses before they are connected to a control system.\n\n\u003cbr\u003e" } ], "value": "\nRecommended security practices and firewall configurations can help protect a process control network from \nattacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and \nare separated from other networks by means of a firewall system that has a minimal number of ports exposed, \nand others that have to be evaluated case by case. Process control systems should not be used for Internet \nsurfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be \ncarefully scanned for viruses before they are connected to a control system.\n\n\n" } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-3353", "datePublished": "2023-02-21T13:50:46.145Z", "dateReserved": "2022-09-28T12:22:08.645Z", "dateUpdated": "2025-03-12T15:17:11.275Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-29492 (GCVE-0-2022-29492)
Vulnerability from cvelistv5
Published
2022-09-14 17:07
Modified
2025-06-04 15:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Hitachi Energy | MicroSCADA X SYS600 |
Version: 10 Version: 10.1 Version: 10.1.1 Version: 10.2 Version: 10.2.1 Version: 10.3 Version: 10.3.1 |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:26:05.982Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-29492", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-04T15:03:06.930475Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-04T15:03:09.994Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10" }, { "status": "affected", "version": "10.1" }, { "status": "affected", "version": "10.1.1" }, { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] }, { "product": "MicroSCADA Pro SYS600", "vendor": "Hitachi Energy", "versions": [ { "lessThanOrEqual": "9.2 FP2 Hotfix 4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2022-09-06T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-14T17:07:31.000Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600 - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600 - Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...", "workarounds": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ], "x_ConverterErrors": { "TITLE": { "error": "TITLE too long. Truncating in v5 record.", "message": "Truncated!" } }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-29492", "STATE": "PUBLIC", "TITLE": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } }, { "product_name": "MicroSCADA Pro SYS600", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "9.2 FP2 Hotfix 4" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600 - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600 - Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-29492", "datePublished": "2022-09-14T17:07:31.147Z", "dateReserved": "2022-04-29T00:00:00.000Z", "dateUpdated": "2025-06-04T15:03:09.994Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-29922 (GCVE-0-2022-29922)
Vulnerability from cvelistv5
Published
2022-09-14 17:03
Modified
2025-06-04 15:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Hitachi Energy | MicroSCADA X SYS600 |
Version: 10 Version: 10.1 Version: 10.1.1 Version: 10.2 Version: 10.2.1 Version: 10.3 Version: 10.3.1 |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:33:43.179Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-29922", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-04T15:06:18.636818Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-04T15:06:31.593Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10" }, { "status": "affected", "version": "10.1" }, { "status": "affected", "version": "10.1.1" }, { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] }, { "product": "MicroSCADA Pro SYS600", "vendor": "Hitachi Energy", "versions": [ { "lessThanOrEqual": "9.2 FP2 Hotfix 4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2022-09-06T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-09-14T17:03:34.000Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600 - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600 - Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS ...", "workarounds": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ], "x_ConverterErrors": { "TITLE": { "error": "TITLE too long. Truncating in v5 record.", "message": "Truncated!" } }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-29922", "STATE": "PUBLIC", "TITLE": "A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } }, { "product_name": "MicroSCADA Pro SYS600", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "9.2 FP2 Hotfix 4" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600 - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600 - Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-29922", "datePublished": "2022-09-14T17:03:34.160Z", "dateReserved": "2022-04-29T00:00:00.000Z", "dateUpdated": "2025-06-04T15:06:31.593Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-09-14 18:15
Modified
2024-11-21 06:41
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
Summary
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_x_sys600 | * | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "0566FCE7-F150-4DEC-A35C-A8A3EBEE8D3D", "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" }, { "lang": "es", "value": "Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en Hitachi Energy MicroSCADA X SYS600 mientras es le\u00eddo un archivo de configuraci\u00f3n espec\u00edfico causa un desbordamiento del b\u00fafer que causa un fallo en el inicio del SYS600. S\u00f3lo puede accederse al archivo de configuraci\u00f3n mediante un acceso de administrador. Este problema afecta a: Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:*" } ], "id": "CVE-2022-1778", "lastModified": "2024-11-21T06:41:26.900", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-14T18:15:09.953", "references": [ { "source": "cybersecurity@hitachienergy.com", "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106\u0026languageCode=en\u0026Preview=true" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-09-14 18:15
Modified
2024-11-21 06:59
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
▶ | URL | Tags | |
---|---|---|---|
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_x_sys600 | * | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD1BD113-3219-458A-82CC-2BCDF55B9A13", "versionEndExcluding": "10.4", "versionStartIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" }, { "lang": "es", "value": "Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en el manejo de un paquete IEC 61850 especialmente dise\u00f1ado con un elemento de datos v\u00e1lido pero con un tipo de datos incorrecto en el Servidor OPC IEC 61850 en Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. La vulnerabilidad puede causar una denegaci\u00f3n de servicio en la parte del servidor OPC IEC 61850 del producto SYS600. Este problema afecta a: Hitachi Energy MicroSCADA Pro SYS600 versi\u00f3n 9.4 FP2 Hotfix 4 y versiones anteriores Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_pro_sys600:9. 2:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_pro_sys600:9. 4:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10. 1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:*" } ], "id": "CVE-2022-29922", "lastModified": "2024-11-21T06:59:58.580", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-14T18:15:10.177", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-02-21 14:29
Modified
2024-11-21 03:59
Severity ?
Summary
This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097.
References
▶ | URL | Tags | |
---|---|---|---|
zdi-disclosures@trendmicro.com | https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC | Mitigation, Vendor Advisory | |
zdi-disclosures@trendmicro.com | https://zerodayinitiative.com/advisories/ZDI-18-141 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://zerodayinitiative.com/advisories/ZDI-18-141 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | sys600_firmware | 9.0 | |
hitachienergy | sys600_firmware | 9.1 | |
hitachienergy | sys600_firmware | 9.1.5 | |
hitachienergy | sys600_firmware | 9.2 | |
hitachienergy | sys600_firmware | 9.4 | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:sys600_firmware:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "89464622-0CF4-4FE0-AE85-441254354707", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:sys600_firmware:9.1:*:*:*:*:*:*:*", "matchCriteriaId": "B3274F16-5E31-4E62-85FB-E068C11C66F1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:sys600_firmware:9.1.5:*:*:*:*:*:*:*", "matchCriteriaId": "F2345B9D-4D12-47C3-850B-58D4C57EC31C", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:sys600_firmware:9.2:*:*:*:*:*:*:*", "matchCriteriaId": "277E4664-6850-4AB1-96D3-FF0DF8A0CBF7", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:sys600_firmware:9.4:*:*:*:*:*:*:*", "matchCriteriaId": "8B4C2E8B-5F82-4157-B40F-72193241C2B1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the configuration of the access controls for the installed product files. The installation procedure leaves critical files open to manipulation by any authenticated user. An attacker can leverage this vulnerability to escalate privileges to SYSTEM. Was ZDI-CAN-5097." }, { "lang": "es", "value": "Esta vulnerabilidad permite que los atacantes locales escalen privilegios en instalaciones vulnerables de ABB MicroSCADA 9.3 con FP 1-2-3. En primer lugar, un atacante debe obtener la capacidad de ejecutar c\u00f3digo de bajos privilegios en el sistema objetivo para explotar esta vulnerabilidad. Este error en concreto existe en la configuraci\u00f3n de los controles de acceso para los archivos del producto instalados. El procedimiento de instalaci\u00f3n hace que archivos cr\u00edticos queden expuestos a ser manipulados por parte de cualquier usuario autenticado. Un atacante puede aprovechar esta vulnerabilidad para escalar privilegios a SYSTEM. Anteriormente era ZDI-CAN-5097." } ], "id": "CVE-2018-1168", "lastModified": "2024-11-21T03:59:19.467", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-02-21T14:29:00.580", "references": [ { "source": "zdi-disclosures@trendmicro.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC" }, { "source": "zdi-disclosures@trendmicro.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-141" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://library.e.abb.com/public/7a88a74b12bb492ea138b1f2365d00f6/ABBVU-PGGA-33888_ABB_SoftwareVulnerabilityHandlingAdvisory_Rev_A.pdf?x-sign=MJfu9cHtRUUubpLAYzyWFTmW5W+mg3kZ/nm7F/Jw5HlFTQf4eNyfLAgE8HozRJEC" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://zerodayinitiative.com/advisories/ZDI-18-141" } ], "sourceIdentifier": "zdi-disclosures@trendmicro.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "zdi-disclosures@trendmicro.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-09-14 18:15
Modified
2024-11-21 07:00
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
▶ | URL | Tags | |
---|---|---|---|
cybersecurity@hitachienergy.com | https://publisher.hitachienergy.com/preview?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | ||
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_x_sys600 | * | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "6D017E2F-F8D8-4755-881A-53415CBC27EE", "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600\u0027s ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" }, { "lang": "es", "value": "Se presenta una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en la pila ICCP de Hitachi Energy MicroSCADA X SYS600 durante el establecimiento de la comunicaci\u00f3n ICCP que causa una denegaci\u00f3n de servicio cuando es solicitado a ICCP de SYS600 que reenv\u00ede cualquier actualizaci\u00f3n de elementos de datos con marcas de tiempo demasiado distantes en el futuro a cualquier sistema ICCP remoto. Por defecto, ICCP no est\u00e1 configurado ni habilitado. Este problema afecta: Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10.2 a versi\u00f3n 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10. 2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "id": "CVE-2022-2277", "lastModified": "2024-11-21T07:00:40.417", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-14T18:15:10.230", "references": [ { "source": "cybersecurity@hitachienergy.com", "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-1284" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-1284" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-21 14:15
Modified
2024-11-21 07:19
Severity ?
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.
An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.
Already existing/established client-server connections are not affected.
List of affected CPEs:
* cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*
* cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*
* cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*
References
▶ | URL | Tags | |
---|---|---|---|
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | sys600_firmware | * | |
hitachienergy | sys600 | - | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | * | |
hitachienergy | rtu500_firmware | 13.4.1 | |
hitachienergy | rtu500 | - | |
hitachienergy | reb500_firmware | * | |
hitachienergy | reb500 | - | |
hitachienergy | pwc600_firmware | 1.0 | |
hitachienergy | pwc600_firmware | 1.1 | |
hitachienergy | pwc600_firmware | 1.2 | |
hitachienergy | pwc600 | - | |
hitachienergy | modular_switchgear_monitoring_firmware | * | |
hitachienergy | modular_switchgear_monitoring | - | |
hitachienergy | itt600_sa_explorer | 1.1.0 | |
hitachienergy | itt600_sa_explorer | 1.1.1 | |
hitachienergy | itt600_sa_explorer | 1.1.2 | |
hitachienergy | itt600_sa_explorer | 1.5.0 | |
hitachienergy | itt600_sa_explorer | 1.5.1 | |
hitachienergy | itt600_sa_explorer | 1.6.0 | |
hitachienergy | itt600_sa_explorer | 1.6.0.1 | |
hitachienergy | itt600_sa_explorer | 1.7.0 | |
hitachienergy | itt600_sa_explorer | 1.7.2 | |
hitachienergy | itt600_sa_explorer | 1.8.0 | |
hitachienergy | itt600_sa_explorer | 2.0.1 | |
hitachienergy | itt600_sa_explorer | 2.0.2 | |
hitachienergy | itt600_sa_explorer | 2.0.3 | |
hitachienergy | itt600_sa_explorer | 2.0.4.1 | |
hitachienergy | itt600_sa_explorer | 2.0.5.0 | |
hitachienergy | itt600_sa_explorer | 2.0.5.4 | |
hitachienergy | itt600_sa_explorer | 2.1.0.4 | |
hitachienergy | itt600_sa_explorer | 2.1.0.5 | |
hitachienergy | relion_sam600-io_firmware | 2.2.1 | |
hitachienergy | relion_sam600-io_firmware | 2.2.5 | |
hitachienergy | relion_sam600-io | - | |
hitachienergy | relion_650_firmware | 1.1 | |
hitachienergy | relion_650_firmware | 1.3 | |
hitachienergy | relion_650_firmware | 2.1 | |
hitachienergy | relion_650_firmware | 2.2.0 | |
hitachienergy | relion_650_firmware | 2.2.1 | |
hitachienergy | relion_650_firmware | 2.2.2 | |
hitachienergy | relion_650_firmware | 2.2.3 | |
hitachienergy | relion_650_firmware | 2.2.4 | |
hitachienergy | relion_650_firmware | 2.2.5 | |
hitachienergy | relion_650 | - | |
hitachienergy | relion_670_firmware | 1.2 | |
hitachienergy | relion_670_firmware | 2.0 | |
hitachienergy | relion_670_firmware | 2.1 | |
hitachienergy | relion_670_firmware | 2.2.0 | |
hitachienergy | relion_670_firmware | 2.2.1 | |
hitachienergy | relion_670_firmware | 2.2.2 | |
hitachienergy | relion_670_firmware | 2.2.3 | |
hitachienergy | relion_670_firmware | 2.2.4 | |
hitachienergy | relion_670_firmware | 2.2.5 | |
hitachienergy | relion_670 | - | |
hitachienergy | gms600_firmware | 1.3.0 | |
hitachienergy | gms600 | - | |
hitachienergy | fox615_tego1_firmware | r1b02 | |
hitachienergy | fox615_tego1_firmware | r1c07 | |
hitachienergy | fox615_tego1_firmware | r1d02 | |
hitachienergy | fox615_tego1_firmware | r1e01 | |
hitachienergy | fox615_tego1_firmware | r2b16 | |
hitachienergy | fox615_tego1_firmware | r2b16_03 | |
hitachienergy | fox615_tego1_firmware | r15b08 | |
hitachienergy | fox615_tego1 | - | |
hitachienergy | txpert_hub_coretec_4_firmware | * | |
hitachienergy | txpert_hub_coretec_4 | - | |
hitachienergy | txpert_hub_coretec_5_firmware | 3.0.0 | |
hitachienergy | txpert_hub_coretec_5 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:sys600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC57CAB3-20C9-44D6-8677-17DBAC8FF49F", "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "469A34A6-EBE4-431C-A986-888BAF525E3C", "versionEndIncluding": "12.0.14.0", "versionStartIncluding": "12.0.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "497CA762-15EB-486D-BCC7-742A44F0DF9D", "versionEndIncluding": "12.2.11.0", "versionStartIncluding": "12.2.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC749956-FA2D-4B16-8401-C015712A934C", "versionEndIncluding": "12.4.11.0", "versionStartIncluding": "12.4.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D25273A-BBD5-4619-93C4-92A12F301088", "versionEndIncluding": "12.6.8.0", "versionStartIncluding": "12.6.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3F726C7-E635-4525-984D-6EADBAA09933", "versionEndIncluding": "12.7.4.0", "versionStartIncluding": "12.7.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC0F3E7E-B079-4488-BED6-E07BDE63C421", "versionEndIncluding": "13.2.5.0", "versionStartIncluding": "13.2.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D04CB998-0D74-4CD1-9F99-773103CB9979", "versionEndIncluding": "13.3.3", "versionStartIncluding": "13.3.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:13.4.1:*:*:*:*:*:*:*", "matchCriteriaId": "C0763F03-C6C8-4104-9028-3CF265F289D5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE94252D-03EE-451B-8322-B4DBC790C6E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:reb500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "432FCDCF-03F2-4A0C-9ACA-73A012F43237", "versionEndExcluding": "8.3.3", "versionStartIncluding": "7.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:reb500:-:*:*:*:*:*:*:*", "matchCriteriaId": "0325854D-52C2-4126-8805-638243FD708E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:pwc600_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "91984E74-C518-472A-ADCF-3BF61781111B", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:pwc600_firmware:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "DAF326E7-792D-434C-9211-F6CEB8B8F1C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:pwc600_firmware:1.2:*:*:*:*:*:*:*", "matchCriteriaId": "9F7F2E89-2095-48F0-A8EA-0C13E10A9362", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:pwc600:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8CBFF7D-3B2E-4FA5-9E0C-15B78AFC8165", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:modular_switchgear_monitoring_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A31EE60F-F80D-40AF-A7C8-8EA462E48918", "versionEndIncluding": "2.2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:modular_switchgear_monitoring:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CBD92D1-045F-44D8-99B1-12C28B0271F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.0:*:*:*:*:*:*:*", "matchCriteriaId": "23F810B7-E97C-4530-A0C5-789D55F4CAE6", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "427E4F50-4077-4515-B2EA-BF57D5A7489C", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.2:*:*:*:*:*:*:*", "matchCriteriaId": "5E44F3FA-1450-4467-A509-6DA42057B69E", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.0:*:*:*:*:*:*:*", "matchCriteriaId": "A67CF9CA-CDF6-4E87-A801-18B34D051A01", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.1:*:*:*:*:*:*:*", "matchCriteriaId": "E327F624-ABE5-408D-AC34-EEE71024B689", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*", "matchCriteriaId": "27E57915-8250-4544-9F5B-FD520BA72F43", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "A0F13838-1555-4206-A4D1-9AFECBBAFD33", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*", "matchCriteriaId": "C74028E3-6FD9-4EAE-BA31-CE1208096ACF", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*", "matchCriteriaId": "F86C507F-0E18-437C-A1A5-258825E78FA9", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*", "matchCriteriaId": "5BE52382-38FA-488F-851D-598AED0C8B6A", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "93C5044A-4AB4-40EF-976F-CDD16FA90F1D", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.2:*:*:*:*:*:*:*", "matchCriteriaId": "1B2696FC-1C4C-4586-854C-7235ADD8376D", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.3:*:*:*:*:*:*:*", "matchCriteriaId": "92B6B5B8-4E81-4450-94E6-CDFA26362A6E", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.4.1:*:*:*:*:*:*:*", "matchCriteriaId": "929384A7-474C-448D-9834-23562CDF2B66", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.5.0:*:*:*:*:*:*:*", "matchCriteriaId": "5DB26367-5B5D-4ED3-A103-204DBCF5CBF2", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.5.4:*:*:*:*:*:*:*", "matchCriteriaId": "4CE69E47-37D7-4F0E-A759-BD54565DF88D", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*", "matchCriteriaId": "FFB8C856-A056-4D7F-8C5D-30A409BCD22C", "vulnerable": true }, { "criteria": "cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*", "matchCriteriaId": "91685621-1937-4494-89AF-7AC1973A2ABE", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*", "matchCriteriaId": "DB5C50F4-CF04-4C13-868A-F7ECE49DE01B", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.5:*:*:*:*:*:*:*", "matchCriteriaId": "698AED51-5521-4D9C-B2FA-F3D8526D9FB6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*", "matchCriteriaId": "E73E9D1A-1DFE-4B7C-81F1-0809071A3DDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "BC40F16C-2EE1-4AEE-BF48-793EFBECDACD", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:1.3:*:*:*:*:*:*:*", "matchCriteriaId": "82F2E748-7331-4B34-8474-A43A1220D208", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.1:*:*:*:*:*:*:*", "matchCriteriaId": "D4C01C39-A91C-437F-BAF9-7E578D703685", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.0:*:*:*:*:*:*:*", "matchCriteriaId": "EA73DFC1-3953-48DB-BF8C-545BE5B7BFAD", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*", "matchCriteriaId": "3A406AD0-38C5-4C32-AA88-AA45EE97C315", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.2:*:*:*:*:*:*:*", "matchCriteriaId": "7B4E0311-0967-4AC9-B426-CAA0AF06855E", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.3:*:*:*:*:*:*:*", "matchCriteriaId": "AB22A258-06C5-48E5-BEF0-9324BD7D301A", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.4:*:*:*:*:*:*:*", "matchCriteriaId": "48B56792-02FF-4E3E-B306-DC58FED37128", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.5:*:*:*:*:*:*:*", "matchCriteriaId": "22E5CD7F-CD9D-4E89-BF2F-944300121D11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C658029-20F4-411A-B1FE-B4E07D590775", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:1.2:*:*:*:*:*:*:*", "matchCriteriaId": "63925E29-DB8F-4568-AD16-41C84A9C8EBC", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "DA499D5E-A693-454D-B28D-E5D2247D1196", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.1:*:*:*:*:*:*:*", "matchCriteriaId": "0F147EE7-0312-4BA6-ABAB-31CCFCA5AA75", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.0:*:*:*:*:*:*:*", "matchCriteriaId": "B91C1D5F-FE14-4121-A7C8-16F08D652610", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.1:*:*:*:*:*:*:*", "matchCriteriaId": "A59F3E51-D3D5-4846-B8AA-6BAD4BCCCCE3", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.2:*:*:*:*:*:*:*", "matchCriteriaId": "E368A106-A236-4A42-8608-43F47EB4A2C4", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.3:*:*:*:*:*:*:*", "matchCriteriaId": "29D2A64B-F136-49B8-9AF8-F8057F9227E0", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.4:*:*:*:*:*:*:*", "matchCriteriaId": "8F2F0B80-070C-4610-862B-346994BFEC51", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.5:*:*:*:*:*:*:*", "matchCriteriaId": "06064F73-366D-48C6-AACE-DCFC2F1B8E0E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*", "matchCriteriaId": "ADA98332-543F-48A7-B63C-B39F679D47F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:gms600_firmware:1.3.0:*:*:*:*:*:*:*", "matchCriteriaId": "C54D374C-379B-4912-9330-30488C19F66C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:gms600:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB13E178-8C41-4FDB-89AE-23D0A9930B94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r1b02:*:*:*:*:*:*:*", "matchCriteriaId": "D7B54A23-399B-4080-A15F-4C0CBA743E67", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r1c07:*:*:*:*:*:*:*", "matchCriteriaId": "8C94ED80-743F-455D-90A4-35FFE7710A5D", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r1d02:*:*:*:*:*:*:*", "matchCriteriaId": "528BF8FA-44BD-40F0-8A60-D0AE659EBBC9", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r1e01:*:*:*:*:*:*:*", "matchCriteriaId": "A16F36DD-FF97-42CE-BB19-B7AE4B15356D", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r2b16:*:*:*:*:*:*:*", "matchCriteriaId": "9E7121E7-7B4E-4CA1-8021-66B324CA2D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r2b16_03:*:*:*:*:*:*:*", "matchCriteriaId": "DBAF5025-6B2A-44C3-99AF-FD10ADFF19B5", "vulnerable": true }, { "criteria": "cpe:2.3:o:hitachienergy:fox615_tego1_firmware:r15b08:*:*:*:*:*:*:*", "matchCriteriaId": "76644F1E-8664-4F70-9553-D773D1362E06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:fox615_tego1:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE327A1-E89A-4A6F-87C7-D2EFF0433380", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:txpert_hub_coretec_4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "419DB11F-2E9E-4E72-B6D4-FE34A4F0B9C6", "versionEndIncluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:txpert_hub_coretec_4:-:*:*:*:*:*:*:*", "matchCriteriaId": "3ADE055E-8EE4-4CCE-9326-B70C101F0EF3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hitachienergy:txpert_hub_coretec_5_firmware:3.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "811B1987-4966-477D-8900-55E522AAC4E0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:txpert_hub_coretec_5:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0266D80-DE86-4BF0-BF39-91EF99C4802C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\n\n\nA vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products.\u00a0\n\nAn attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections.\u00a0\n\n\n\n\nAlready existing/established client-server connections are not affected.\n\n\n\n\n\nList of affected CPEs:\n\n\n\n\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*\n * cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*\n * cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*\n\n\n\n\n\n\n" } ], "id": "CVE-2022-3353", "lastModified": "2024-11-21T07:19:21.390", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-21T14:15:13.463", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000124\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000125\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000126\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000127\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000128\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000129\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000130\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000131\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000132\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000133\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-404" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-404" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-09-12 21:15
Modified
2024-11-21 06:59
Severity ?
8.5 (High) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
▶ | URL | Tags | |
---|---|---|---|
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_x_sys600 | * | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "0566FCE7-F150-4DEC-A35C-A8A3EBEE8D3D", "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" }, { "lang": "es", "value": "Se presenta una vulnerabilidad de Autorizaci\u00f3n Inapropiada en la WebUI de Workplace X de Hitachi Energy MicroSCADA X SYS600 que permite a un usuario autenticado ejecutar cualquier script interno de MicroSCADA independientemente del rol del usuario autenticado. Este problema afecta: Hitachi Energy MicroSCADA X SYS600 versiones 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "id": "CVE-2022-29490", "lastModified": "2024-11-21T06:59:10.850", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 6.0, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-12T21:15:10.010", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-285" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2022-09-14 18:15
Modified
2024-11-21 06:59
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
References
▶ | URL | Tags | |
---|---|---|---|
cybersecurity@hitachienergy.com | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_x_sys600 | * | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD1BD113-3219-458A-82CC-2BCDF55B9A13", "versionEndExcluding": "10.4", "versionStartIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" }, { "lang": "es", "value": "Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en el manejo de un paquete TCP IEC 104 malformado en Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Al recibir un paquete TCP IEC 104 malformado, el paquete malformado es descartado, pero la conexi\u00f3n TCP es dejada abierta. Esto puede causar una denegaci\u00f3n de servicio si la conexi\u00f3n afectada es dejada abierta. Este problema afecta a: Hitachi Energy MicroSCADA Pro SYS600 versi\u00f3n 9.4 FP2 Hotfix 4 y versiones anteriores Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_pro_sys600:9. 2:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_pro_sys600:9. 4:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10. 1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:*" } ], "id": "CVE-2022-29492", "lastModified": "2024-11-21T06:59:11.120", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-14T18:15:10.117", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }