Vulnerabilites related to br-automation - technology_guarding
CVE-2024-0220 (GCVE-0-2024-0220)
Vulnerability from cvelistv5
Published
2024-02-22 10:15
Modified
2024-09-19 17:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | B&R Industrial Automation | Automation Studio |
Version: 4.0 |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T17:41:15.976Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "automation_studio", "vendor": "br-automation", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "4.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-0220", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-02-22T16:23:26.378691Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-28T16:52:09.908Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "modules": [ "Upgrade Service" ], "product": "Automation Studio", "vendor": "B\u0026R Industrial Automation", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "4.0", "versionType": "patch" } ] }, { "defaultStatus": "unaffected", "product": "Technology Guarding", "vendor": "B\u0026R Industrial Automation", "versions": [ { "lessThan": "1.4.0", "status": "affected", "version": "1.0.0", "versionType": "patch" } ] } ], "datePublic": "2024-02-22T10:10:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "B\u0026amp;R Automation Studio Upgrade Service and B\u0026amp;R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.\n\n\u003cbr\u003e" } ], "value": "B\u0026R Automation Studio Upgrade Service and B\u0026R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1240", "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-19T17:24:51.723Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf" } ], "source": { "advisory": "2023-P019", "discovery": "INTERNAL" }, "title": "B\u0026R products use insufficient communication encryption", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2024-0220", "datePublished": "2024-02-22T10:15:44.750Z", "dateReserved": "2024-01-03T15:46:41.224Z", "dateUpdated": "2024-09-19T17:24:51.723Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2024-02-22 11:15
Modified
2025-05-06 17:28
Severity ?
8.3 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
8.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
8.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
br-automation | automation_studio | * | |
br-automation | technology_guarding | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD356F7B-A7B5-4D27-B270-4C2174C29985", "versionEndExcluding": "4.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:br-automation:technology_guarding:*:*:*:*:*:*:*:*", "matchCriteriaId": "61EBB91B-EFA1-4D6F-8121-A665EBF25D91", "versionEndExcluding": "1.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "B\u0026R Automation Studio Upgrade Service and B\u0026R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data." }, { "lang": "es", "value": "B\u0026amp;R Automation Studio Upgrade Service y B\u0026amp;R Technology Guarding utilizan criptograf\u00eda insuficiente para la comunicaci\u00f3n con la actualizaci\u00f3n y los servidores de licencias. Un atacante basado en la red podr\u00eda aprovechar la vulnerabilidad para ejecutar c\u00f3digo arbitrario en los productos o rastrear datos confidenciales. Falta de cifrado de datos confidenciales, transmisi\u00f3n de texto plano de informaci\u00f3n confidencial, control inadecuado de la generaci\u00f3n de c\u00f3digo (\"inyecci\u00f3n de c\u00f3digo\"), vulnerabilidad de fuerza de cifrado inadecuada en B\u0026amp;R Industrial Automation B\u0026amp;R Automation Studio (m\u00f3dulos de servicio de actualizaci\u00f3n), B\u0026amp;R Industrial Automation Technology Guarding.Este problema afecta a B\u0026amp;R Automation Studio: \u0026lt;4,6; Protecci\u00f3n de tecnolog\u00eda: \u0026lt;1.4.0." } ], "id": "CVE-2024-0220", "lastModified": "2025-05-06T17:28:17.343", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 6.0, "source": "cybersecurity@ch.abb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-02-22T11:15:08.840", "references": [ { "source": "cybersecurity@ch.abb.com", "tags": [ "Vendor Advisory" ], "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf" } ], "sourceIdentifier": "cybersecurity@ch.abb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-94" }, { "lang": "en", "value": "CWE-319" }, { "lang": "en", "value": "CWE-1240" } ], "source": "cybersecurity@ch.abb.com", "type": "Primary" } ] }