Vulnerabilites related to siemens - telecontrol_server_basic
CVE-2025-32849 (GCVE-0-2025-32849)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32849",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:21.992703Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:35.028Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockSmtpSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:27.510Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32849",
    "datePublished": "2025-04-16T17:38:27.510Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:35.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32828 (GCVE-0-2025-32828)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32828",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:16.424419Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:13.879Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProjectCrossCommunications\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:55.116Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32828",
    "datePublished": "2025-04-16T17:37:55.116Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-17T14:20:13.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32853 (GCVE-0-2025-32853)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32853",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:10.640723Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:05.765Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockDatabaseSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:33.094Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32853",
    "datePublished": "2025-04-16T17:38:33.094Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:05.765Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32858 (GCVE-0-2025-32858)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32858",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:55.745519Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:28.322Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateWebServerGatewaySettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:40.150Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32858",
    "datePublished": "2025-04-16T17:38:40.150Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:28.322Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32824 (GCVE-0-2025-32824)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32824",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:19.149517Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:20.759Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:49.168Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32824",
    "datePublished": "2025-04-16T17:37:49.168Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-17T14:20:20.759Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30031 (GCVE-0-2025-30031)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:02
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25922)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30031",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:02:06.657190Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:02:18.556Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateUsers\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25922)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:33.194Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30031",
    "datePublished": "2025-04-16T17:37:33.194Z",
    "dateReserved": "2025-03-14T09:04:02.457Z",
    "dateUpdated": "2025-04-16T18:02:18.556Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32831 (GCVE-0-2025-32831)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32831",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:07.834414Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:48.946Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProjectUserRights\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:59.574Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32831",
    "datePublished": "2025-04-16T17:37:59.574Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:48.946Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32845 (GCVE-0-2025-32845)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32845",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:33.080610Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:04.695Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateGeneralSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:20.710Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32845",
    "datePublished": "2025-04-16T17:38:20.710Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:18:04.695Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31353 (GCVE-0-2025-31353)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25916)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31353",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:30.275180Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:55.144Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateOpcSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25916)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:43.360Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31353",
    "datePublished": "2025-04-16T17:37:43.360Z",
    "dateReserved": "2025-03-28T07:39:49.192Z",
    "dateUpdated": "2025-04-17T14:20:55.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32823 (GCVE-0-2025-32823)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32823",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:21.862934Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:29.103Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:47.704Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32823",
    "datePublished": "2025-04-16T17:37:47.704Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-17T14:20:29.103Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32835 (GCVE-0-2025-32835)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32835",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:59.776240Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:23.285Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateConnectionVariableArchivingBuffering\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:05.783Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32835",
    "datePublished": "2025-04-16T17:38:05.783Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:23.285Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32832 (GCVE-0-2025-32832)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-16 18:40
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32832",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:40:02.639303Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:40:32.614Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockProjectUserRights\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:00.996Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32832",
    "datePublished": "2025-04-16T17:38:00.996Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-16T18:40:32.614Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29905 (GCVE-0-2025-29905)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:04
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-29905",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:04:07.846268Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:04:16.027Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027RestoreFromBackup\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:27.208Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-29905",
    "datePublished": "2025-04-16T17:37:27.208Z",
    "dateReserved": "2025-03-12T13:34:52.658Z",
    "dateUpdated": "2025-04-16T18:04:16.027Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32854 (GCVE-0-2025-32854)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32854",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:07.849979Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:57.586Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockOpcSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:34.488Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32854",
    "datePublished": "2025-04-16T17:38:34.488Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:57.586Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32865 (GCVE-0-2025-32865)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32865",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:31.674987Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:32.335Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateLog\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:50.158Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32865",
    "datePublished": "2025-04-16T17:38:50.158Z",
    "dateReserved": "2025-04-11T13:04:54.890Z",
    "dateUpdated": "2025-04-17T14:15:32.335Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32837 (GCVE-0-2025-32837)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32837",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:54.696887Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:09.202Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetActiveConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:08.705Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32837",
    "datePublished": "2025-04-16T17:38:08.705Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:09.202Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32475 (GCVE-0-2025-32475)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25912)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32475",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:27.263301Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:45.886Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25912)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:44.778Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32475",
    "datePublished": "2025-04-16T17:37:44.778Z",
    "dateReserved": "2025-04-09T08:39:32.636Z",
    "dateUpdated": "2025-04-17T14:20:45.886Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6575 (GCVE-0-2019-6575)
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Severity ?
CWE
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
References
Impacted products
Vendor Product Version
Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Create a notification for this product.
   Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V2.7
Create a notification for this product.
   Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Version: All versions < V15.1 Upd 4
Create a notification for this product.
   Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Version: All versions < V15.1 Upd 4
Create a notification for this product.
   Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Version: All versions < V15.1 Upd 4
Create a notification for this product.
   Siemens SIMATIC IPC DiagMonitor Version: All versions < V5.1.3
Create a notification for this product.
   Siemens SIMATIC NET PC Software V13 Version: All versions
Create a notification for this product.
   Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Create a notification for this product.
   Siemens SIMATIC NET PC Software V15 Version: All versions
Create a notification for this product.
   Siemens SIMATIC RF188C Version: All versions < V1.1.0
Create a notification for this product.
   Siemens SIMATIC RF600R family Version: All versions < V3.2.1
Create a notification for this product.
   Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions >= V2.5 < V2.6.1
Create a notification for this product.
   Siemens SIMATIC S7-1500 Software Controller Version: All versions between V2.5 (including) and V2.7 (excluding)
Create a notification for this product.
   Siemens SIMATIC WinCC OA Version: All versions < V3.15 P018
Create a notification for this product.
   Siemens SIMATIC WinCC Runtime Advanced Version: All versions < V15.1 Upd 4
Create a notification for this product.
   Siemens SINEC NMS Version: All versions < V1.0 SP1
Create a notification for this product.
   Siemens SINEMA Server Version: All versions < V14 SP2
Create a notification for this product.
   Siemens SINUMERIK OPC UA Server Version: All versions < V2.1
Create a notification for this product.
   Siemens TeleControl Server Basic Version: All versions < V3.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.041Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.5 \u003c V2.6.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions between V2.5 (including) and V2.7 (excluding)"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.15 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP1"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP2"
            }
          ]
        },
        {
          "product": "SINUMERIK OPC UA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6575",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC CP 443-1 OPC UA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC IPC DiagMonitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Update 14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RF188C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RF600R family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.2.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.5 \u003c V2.6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions between V2.5 (including) and V2.7 (excluding)"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC OA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.15 P018"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINEC NMS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINEMA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINUMERIK OPC UA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TeleControl Server Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6575",
    "datePublished": "2019-04-17T13:40:24",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32859 (GCVE-0-2025-32859)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32859",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:52.572306Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:21.247Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockWebServerGatewaySettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:41.565Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32859",
    "datePublished": "2025-04-16T17:38:41.565Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:21.247Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45117 (GCVE-0-2021-45117)
Vulnerability from cvelistv5
Published
2022-03-21 14:05
Modified
2024-08-04 04:39
Severity ?
CWE
  • n/a
Summary
The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:20.271Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.youtube.com/watch?v=qv-RBdCaV4k"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T11:06:11",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.youtube.com/watch?v=qv-RBdCaV4k"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45117",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.youtube.com/watch?v=qv-RBdCaV4k",
              "refsource": "MISC",
              "url": "https://www.youtube.com/watch?v=qv-RBdCaV4k"
            },
            {
              "name": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf",
              "refsource": "MISC",
              "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45117",
    "datePublished": "2022-03-21T14:05:45",
    "dateReserved": "2021-12-16T00:00:00",
    "dateUpdated": "2024-08-04T04:39:20.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32830 (GCVE-0-2025-32830)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32830",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:10.869084Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:58.370Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:58.050Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32830",
    "datePublished": "2025-04-16T17:37:58.050Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:58.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-40142 (GCVE-0-2021-40142)
Vulnerability from cvelistv5
Published
2021-08-27 06:51
Modified
2024-08-04 02:27
CWE
  • n/a
Summary
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:27:31.711Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://opcfoundation.org/security-bulletins/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:N/I:N/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T11:06:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://opcfoundation.org/security-bulletins/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-40142",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:N/I:N/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://opcfoundation.org/security-bulletins/",
              "refsource": "MISC",
              "url": "https://opcfoundation.org/security-bulletins/"
            },
            {
              "name": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf",
              "refsource": "MISC",
              "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-40142",
    "datePublished": "2021-08-27T06:51:28",
    "dateReserved": "2021-08-25T00:00:00",
    "dateUpdated": "2024-08-04T02:27:31.711Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32864 (GCVE-0-2025-32864)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32864",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:34.597164Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:39.703Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:48.731Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32864",
    "datePublished": "2025-04-16T17:38:48.731Z",
    "dateReserved": "2025-04-11T13:04:54.890Z",
    "dateUpdated": "2025-04-17T14:15:39.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32856 (GCVE-0-2025-32856)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32856",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:01.984984Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:42.599Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockBufferingSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:37.361Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32856",
    "datePublished": "2025-04-16T17:38:37.361Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:42.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32844 (GCVE-0-2025-32844)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32844",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:35.722999Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:13.396Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockUser\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:19.293Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32844",
    "datePublished": "2025-04-16T17:38:19.293Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:18:13.396Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-4837 (GCVE-0-2018-4837)
Vulnerability from cvelistv5
Published
2018-01-25 14:00
Modified
2024-09-16 16:22
Severity ?
CWE
  • CWE-400 - Uncontrolled Resource Consumption ('Resource Exhaustion')
Summary
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition.
Impacted products
Vendor Product Version
Siemens AG TeleControl Server Basic Version: All versions < V3.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.525Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
          },
          {
            "name": "102819",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102819"
          },
          {
            "name": "102904",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102904"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TeleControl Server Basic",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1"
            }
          ]
        }
      ],
      "datePublic": "2018-01-25T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An attacker with access to the TeleControl Server Basic\u0027s webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-02-03T10:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
        },
        {
          "name": "102819",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102819"
        },
        {
          "name": "102904",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102904"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "DATE_PUBLIC": "2018-01-25T00:00:00",
          "ID": "CVE-2018-4837",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TeleControl Server Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An attacker with access to the TeleControl Server Basic\u0027s webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400: Uncontrolled Resource Consumption (\u0027Resource Exhaustion\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
            },
            {
              "name": "102819",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102819"
            },
            {
              "name": "102904",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102904"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4837",
    "datePublished": "2018-01-25T14:00:00Z",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-09-16T16:22:25.673Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32855 (GCVE-0-2025-32855)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32855",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:04.890208Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:50.126Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockOpcSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:35.963Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32855",
    "datePublished": "2025-04-16T17:38:35.963Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:50.126Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32822 (GCVE-0-2025-32822)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'DeleteProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32822",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:24.517852Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:38.846Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027DeleteProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:46.225Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32822",
    "datePublished": "2025-04-16T17:37:46.225Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-17T14:20:38.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32825 (GCVE-0-2025-32825)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:51
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32825",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:50:12.327504Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:51:30.717Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetProjects\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:50.627Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32825",
    "datePublished": "2025-04-16T17:37:50.627Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-16T18:51:30.717Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32851 (GCVE-0-2025-32851)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32851",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:16.179897Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:20.517Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockTcmSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:30.324Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32851",
    "datePublished": "2025-04-16T17:38:30.324Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:20.517Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32833 (GCVE-0-2025-32833)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32833",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:05.311954Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:38.929Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockProjectUserRights\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:02.590Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32833",
    "datePublished": "2025-04-16T17:38:02.590Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:38.929Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27539 (GCVE-0-2025-27539)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:26
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27539",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:04:28.281247Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:26:56.263Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027VerifyUser\u0027 method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.  (ZDI-CAN-25914)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:24.315Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-27539",
    "datePublished": "2025-04-16T17:37:24.315Z",
    "dateReserved": "2025-02-28T15:17:08.229Z",
    "dateUpdated": "2025-04-17T14:26:56.263Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32869 (GCVE-0-2025-32869)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:14
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32869",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:20.427017Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:14:58.053Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ImportCertificate\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:55.788Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32869",
    "datePublished": "2025-04-16T17:38:55.788Z",
    "dateReserved": "2025-04-11T14:43:48.755Z",
    "dateUpdated": "2025-04-17T14:14:58.053Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32871 (GCVE-0-2025-32871)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:14
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32871",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:14.161506Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:14:44.243Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027MigrateDatabase\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:58.559Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32871",
    "datePublished": "2025-04-16T17:38:58.559Z",
    "dateReserved": "2025-04-11T14:43:48.755Z",
    "dateUpdated": "2025-04-17T14:14:44.243Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27540 (GCVE-0-2025-27540)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:21
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'Authenticate' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27540",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:04:25.401566Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:21:07.947Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027Authenticate\u0027 method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:25.783Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-27540",
    "datePublished": "2025-04-16T17:37:25.783Z",
    "dateReserved": "2025-02-28T15:19:42.937Z",
    "dateUpdated": "2025-04-17T14:21:07.947Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30030 (GCVE-0-2025-30030)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:02
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30030",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:02:47.089975Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:02:54.229Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ImportDatabase\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:31.712Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30030",
    "datePublished": "2025-04-16T17:37:31.712Z",
    "dateReserved": "2025-03-14T09:04:02.456Z",
    "dateUpdated": "2025-04-16T18:02:54.229Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31350 (GCVE-0-2025-31350)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 17:59
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25918)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31350",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:59:43.023872Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:59:54.324Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateBufferingSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25918)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:38.885Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31350",
    "datePublished": "2025-04-16T17:37:38.885Z",
    "dateReserved": "2025-03-28T07:33:21.119Z",
    "dateUpdated": "2025-04-16T17:59:54.324Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32866 (GCVE-0-2025-32866)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32866",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:28.670633Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:24.860Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetLogs\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:51.620Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32866",
    "datePublished": "2025-04-16T17:38:51.620Z",
    "dateReserved": "2025-04-11T13:04:54.890Z",
    "dateUpdated": "2025-04-17T14:15:24.860Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32868 (GCVE-0-2025-32868)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32868",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:23.118963Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:05.868Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ExportCertificate\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:54.410Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32868",
    "datePublished": "2025-04-16T17:38:54.410Z",
    "dateReserved": "2025-04-11T14:43:48.755Z",
    "dateUpdated": "2025-04-17T14:15:05.868Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32870 (GCVE-0-2025-32870)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:14
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32870",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:17.346672Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:14:51.304Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetTraces\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:57.182Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32870",
    "datePublished": "2025-04-16T17:38:57.182Z",
    "dateReserved": "2025-04-11T14:43:48.755Z",
    "dateUpdated": "2025-04-17T14:14:51.304Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32848 (GCVE-0-2025-32848)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32848",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:24.521387Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:42.633Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockSmtpSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:26.132Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32848",
    "datePublished": "2025-04-16T17:38:26.132Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:42.633Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32862 (GCVE-0-2025-32862)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32862",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:40.671466Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:56.995Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockTraceLevelSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:45.949Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32862",
    "datePublished": "2025-04-16T17:38:45.949Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:15:56.995Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27495 (GCVE-0-2025-27495)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:27
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateTrace' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27495",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:04:31.154253Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:27:03.989Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateTrace\u0027 method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:22.667Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-27495",
    "datePublished": "2025-04-16T17:37:22.667Z",
    "dateReserved": "2025-02-26T18:05:35.965Z",
    "dateUpdated": "2025-04-17T14:27:03.989Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32846 (GCVE-0-2025-32846)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32846",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:29.850924Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:57.268Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockGeneralSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:23.275Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32846",
    "datePublished": "2025-04-16T17:38:23.275Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:57.268Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-4835 (GCVE-0-2018-4835)
Vulnerability from cvelistv5
Published
2018-01-25 14:00
Modified
2024-09-17 02:58
Severity ?
CWE
  • CWE-287 - Improper Authentication
Summary
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
Impacted products
Vendor Product Version
Siemens AG TeleControl Server Basic Version: All versions < V3.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.203Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
          },
          {
            "name": "102894",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102894"
          },
          {
            "name": "102904",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102904"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TeleControl Server Basic",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1"
            }
          ]
        }
      ],
      "datePublic": "2018-01-25T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An attacker with network access to the TeleControl Server Basic\u0027s port 8000/tcp could bypass the authentication mechanism and read limited information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-02-03T10:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
        },
        {
          "name": "102894",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102894"
        },
        {
          "name": "102904",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102904"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "DATE_PUBLIC": "2018-01-25T00:00:00",
          "ID": "CVE-2018-4835",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TeleControl Server Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An attacker with network access to the TeleControl Server Basic\u0027s port 8000/tcp could bypass the authentication mechanism and read limited information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
            },
            {
              "name": "102894",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102894"
            },
            {
              "name": "102904",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102904"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4835",
    "datePublished": "2018-01-25T14:00:00Z",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-09-17T02:58:06.169Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32829 (GCVE-0-2025-32829)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:20
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32829",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:13.492354Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:20:07.329Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockProjectCrossCommunications\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:56.625Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32829",
    "datePublished": "2025-04-16T17:37:56.625Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-17T14:20:07.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30003 (GCVE-0-2025-30003)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:03
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectConnections' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30003",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:03:06.314022Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:03:14.827Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProjectConnections\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:30.275Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30003",
    "datePublished": "2025-04-16T17:37:30.275Z",
    "dateReserved": "2025-03-13T17:06:26.285Z",
    "dateUpdated": "2025-04-16T18:03:14.827Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32834 (GCVE-0-2025-32834)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32834",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:02.434507Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:31.356Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateConnectionVariablesWithImport\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:04.036Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32834",
    "datePublished": "2025-04-16T17:38:04.036Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:31.356Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32867 (GCVE-0-2025-32867)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32867",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:25.878383Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:15.038Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateBackup\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:53.028Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32867",
    "datePublished": "2025-04-16T17:38:53.028Z",
    "dateReserved": "2025-04-11T14:43:48.754Z",
    "dateUpdated": "2025-04-17T14:15:15.038Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32857 (GCVE-0-2025-32857)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32857",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:58.633936Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:35.577Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockBufferingSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:38.756Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32857",
    "datePublished": "2025-04-16T17:38:38.756Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:35.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30032 (GCVE-0-2025-30032)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:01
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25921)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30032",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:01:40.301395Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:01:50.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateDatabaseSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25921)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:34.628Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30032",
    "datePublished": "2025-04-16T17:37:34.628Z",
    "dateReserved": "2025-03-14T09:04:02.457Z",
    "dateUpdated": "2025-04-16T18:01:50.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32840 (GCVE-0-2025-32840)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32840",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:46.912867Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:44.164Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockGateway\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:13.513Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32840",
    "datePublished": "2025-04-16T17:38:13.513Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:18:44.164Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32843 (GCVE-0-2025-32843)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32843",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:38.711238Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:20.843Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockUser\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:17.866Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32843",
    "datePublished": "2025-04-16T17:38:17.866Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:18:20.843Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31352 (GCVE-0-2025-31352)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-17 14:21
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31352",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:07:32.890697Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:21:01.036Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateGateways\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:41.903Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31352",
    "datePublished": "2025-04-16T17:37:41.903Z",
    "dateReserved": "2025-03-28T07:37:51.131Z",
    "dateUpdated": "2025-04-17T14:21:01.036Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-44102 (GCVE-0-2024-44102)
Vulnerability from cvelistv5
Published
2024-11-12 12:49
Modified
2024-11-15 19:24
CWE
  • CWE-502 - Deserialization of Untrusted Data
Summary
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Impacted products
Vendor Product Version
Siemens PP TeleControl Server Basic 1000 to 5000 V3.1 Version: 0   < V3.1.2.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "telecontrol_server_basic",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "3.1.2.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-44102",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-15T19:24:38.461958Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-15T19:24:48.170Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "PP TeleControl Server Basic 1000 to 5000 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PP TeleControl Server Basic 256 to 1000 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PP TeleControl Server Basic 32 to 64 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PP TeleControl Server Basic 64 to 256 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PP TeleControl Server Basic 8 to 32 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic 1000 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic 256 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic 32 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic 5000 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic 64 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic 8 V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic Serv Upgr",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic Upgr V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions \u003c V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502: Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T12:49:33.464Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-454789.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-44102",
    "datePublished": "2024-11-12T12:49:33.464Z",
    "dateReserved": "2024-08-20T06:28:50.265Z",
    "dateUpdated": "2024-11-15T19:24:48.170Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32842 (GCVE-0-2025-32842)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32842",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:41.589932Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:28.186Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetUsers\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:16.457Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32842",
    "datePublished": "2025-04-16T17:38:16.457Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:18:28.186Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32861 (GCVE-0-2025-32861)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32861",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:44.300557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:05.840Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateTraceLevelSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:44.533Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32861",
    "datePublished": "2025-04-16T17:38:44.533Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:05.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32850 (GCVE-0-2025-32850)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32850",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:18.975932Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:28.042Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockTcmSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:28.950Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32850",
    "datePublished": "2025-04-16T17:38:28.950Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:28.042Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32827 (GCVE-0-2025-32827)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:46
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ActivateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32827",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:46:29.266259Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:46:42.199Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ActivateProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:53.691Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32827",
    "datePublished": "2025-04-16T17:37:53.691Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-16T18:46:42.199Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32836 (GCVE-0-2025-32836)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32836",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:57.197839Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:16.680Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:07.241Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32836",
    "datePublished": "2025-04-16T17:38:07.241Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:16.680Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31349 (GCVE-0-2025-31349)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:00
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31349",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:00:28.490803Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:00:39.407Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateSmtpSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:37.460Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31349",
    "datePublished": "2025-04-16T17:37:37.460Z",
    "dateReserved": "2025-03-28T07:31:27.306Z",
    "dateUpdated": "2025-04-16T18:00:39.407Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31351 (GCVE-0-2025-31351)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 17:59
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25917)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31351",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:58:50.289178Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:59:04.245Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25917)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:40.308Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31351",
    "datePublished": "2025-04-16T17:37:40.308Z",
    "dateReserved": "2025-03-28T07:34:58.810Z",
    "dateUpdated": "2025-04-16T17:59:04.245Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32847 (GCVE-0-2025-32847)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32847",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:27.073513Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:50.095Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockGeneralSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:24.769Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32847",
    "datePublished": "2025-04-16T17:38:24.769Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:50.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32841 (GCVE-0-2025-32841)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32841",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:44.272723Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:37.206Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockGateway\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:14.980Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32841",
    "datePublished": "2025-04-16T17:38:14.980Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:18:37.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32839 (GCVE-0-2025-32839)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:18
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32839",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:49.511496Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:18:52.300Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetGateways\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:11.668Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32839",
    "datePublished": "2025-04-16T17:38:11.668Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:18:52.300Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-30002 (GCVE-0-2025-30002)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:03
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30002",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:03:27.961076Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:03:51.229Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:28.831Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30002",
    "datePublished": "2025-04-16T17:37:28.831Z",
    "dateReserved": "2025-03-13T17:00:37.107Z",
    "dateUpdated": "2025-04-16T18:03:51.229Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-4836 (GCVE-0-2018-4836)
Vulnerability from cvelistv5
Published
2018-01-25 14:00
Modified
2024-09-16 17:32
Severity ?
CWE
  • CWE-287 - Improper Authentication
Summary
A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.
Impacted products
Vendor Product Version
Siemens AG TeleControl Server Basic Version: All versions < V3.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.576Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
          },
          {
            "name": "102904",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102904"
          },
          {
            "name": "102897",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102897"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TeleControl Server Basic",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1"
            }
          ]
        }
      ],
      "datePublic": "2018-01-25T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic\u0027s port 8000/tcp could escalate his privileges and perform administrative operations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-02-03T10:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
        },
        {
          "name": "102904",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102904"
        },
        {
          "name": "102897",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102897"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "DATE_PUBLIC": "2018-01-25T00:00:00",
          "ID": "CVE-2018-4836",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TeleControl Server Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic\u0027s port 8000/tcp could escalate his privileges and perform administrative operations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
            },
            {
              "name": "102904",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102904"
            },
            {
              "name": "102897",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102897"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4836",
    "datePublished": "2018-01-25T14:00:00Z",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-09-16T17:32:46.608Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32852 (GCVE-0-2025-32852)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:17
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32852",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:13.432073Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:17:12.534Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockDatabaseSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:31.692Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32852",
    "datePublished": "2025-04-16T17:38:31.692Z",
    "dateReserved": "2025-04-11T13:04:54.888Z",
    "dateUpdated": "2025-04-17T14:17:12.534Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32826 (GCVE-0-2025-32826)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:48
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32826",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:48:34.897874Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:48:46.448Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetActiveProjects\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:52.113Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32826",
    "datePublished": "2025-04-16T17:37:52.113Z",
    "dateReserved": "2025-04-11T13:04:54.886Z",
    "dateUpdated": "2025-04-16T18:48:46.448Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-31343 (GCVE-0-2025-31343)
Vulnerability from cvelistv5
Published
2025-04-16 17:37
Modified
2025-04-16 18:01
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-31343",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T18:01:05.556617Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:01:16.379Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateTcmSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:37:36.060Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-31343",
    "datePublished": "2025-04-16T17:37:36.060Z",
    "dateReserved": "2025-03-28T07:29:17.411Z",
    "dateUpdated": "2025-04-16T18:01:16.379Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32860 (GCVE-0-2025-32860)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:16
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32860",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:48.045622Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:16:13.625Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockWebServerGatewaySettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:43.055Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32860",
    "datePublished": "2025-04-16T17:38:43.055Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:16:13.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32838 (GCVE-0-2025-32838)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:19
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32838",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:06:52.181914Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:19:01.016Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ImportConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:10.118Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32838",
    "datePublished": "2025-04-16T17:38:10.118Z",
    "dateReserved": "2025-04-11T13:04:54.887Z",
    "dateUpdated": "2025-04-17T14:19:01.016Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32863 (GCVE-0-2025-32863)
Vulnerability from cvelistv5
Published
2025-04-16 17:38
Modified
2025-04-17 14:15
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32863",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:37.474811Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:15:48.108Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockTraceLevelSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:38:47.349Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32863",
    "datePublished": "2025-04-16T17:38:47.349Z",
    "dateReserved": "2025-04-11T13:04:54.889Z",
    "dateUpdated": "2025-04-17T14:15:48.108Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-32872 (GCVE-0-2025-32872)
Vulnerability from cvelistv5
Published
2025-04-16 17:39
Modified
2025-04-17 14:14
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-32872",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:05:11.009527Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:14:36.389Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetOverview\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-16T17:39:00.326Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-32872",
    "datePublished": "2025-04-16T17:39:00.326Z",
    "dateReserved": "2025-04-11T14:43:48.755Z",
    "dateUpdated": "2025-04-17T14:14:36.389Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29931 (GCVE-0-2025-29931)
Vulnerability from cvelistv5
Published
2025-04-17 11:05
Modified
2025-04-17 14:43
CWE
  • CWE-130 - Improper Handling of Length Parameter Inconsistency
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.
Impacted products
Vendor Product Version
Siemens TeleControl Server Basic Version: 0   < V3.1.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-29931",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-17T14:43:20.510525Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T14:43:50.005Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition.\r\nSuccessful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-130",
              "description": "CWE-130: Improper Handling of Length Parameter Inconsistency",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-17T11:05:57.612Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-395348.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-29931",
    "datePublished": "2025-04-17T11:05:57.612Z",
    "dateReserved": "2025-03-12T13:47:09.580Z",
    "dateUpdated": "2025-04-17T14:43:50.005Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2022-03-21 15:15
Modified
2024-11-21 06:31
Summary
The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:opcfoundation:ua-nodeset:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F2AA77-409B-48CA-9BBE-6EC6B5BA9EAF",
              "versionEndExcluding": "1.05.01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "298E8F34-346B-4FC5-8690-3F947F585552",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*",
              "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*",
              "matchCriteriaId": "AFBD6DDF-917C-44CC-A944-1945DC7AC9FB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sitop_manager:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F1ABC40-2C91-4EA9-9442-16E5D7C29E52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "975FC6E7-8FDB-4361-A691-44B26B0CBFD4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference."
    },
    {
      "lang": "es",
      "value": "Los stubs de pila ANSI C autogenerados por OPC (en los NodeSets) no manejan todos los casos de error. Esto puede conllevar a una desreferencia de puntero NULL"
    }
  ],
  "id": "CVE-2021-45117",
  "lastModified": "2024-11-21T06:31:59.667",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-03-21T15:15:07.927",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.youtube.com/watch?v=qv-RBdCaV4k"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.youtube.com/watch?v=qv-RBdCaV4k"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-01-25 14:29
Modified
2024-11-21 04:07
Summary
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E31D80D0-A773-45F5-8155-43861100BC48",
              "versionEndExcluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An attacker with network access to the TeleControl Server Basic\u0027s port 8000/tcp could bypass the authentication mechanism and read limited information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic en versiones anteriores a la 3.1. Un atacante con acceso de red al puerto 8000/tcp de TeleControl Server Basic podr\u00eda evadir el mecanismo de autenticaci\u00f3n y leer informaci\u00f3n limitada."
    }
  ],
  "id": "CVE-2018-4835",
  "lastModified": "2024-11-21T04:07:33.033",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-01-25T14:29:00.320",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102894"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102904"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102894"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102904"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32830",
  "lastModified": "2025-08-19T15:23:16.950",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.653",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProjectUserRights\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateProjectUserRights\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32831",
  "lastModified": "2025-08-19T15:23:14.793",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.797",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:57
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25916)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateOpcSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25916)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateOpcSettings\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \u00abNT AUTHORITY\\NetworkService\u00bb. Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25916)"
    }
  ],
  "id": "CVE-2025-31353",
  "lastModified": "2025-08-19T14:57:16.157",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:07.670",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockGateway\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockGateway\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32841",
  "lastModified": "2025-08-19T15:22:46.240",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:12.273",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:58
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProjectCrossCommunications\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateProjectCrossCommunications\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32828",
  "lastModified": "2025-08-19T14:58:36.160",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.360",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-11-12 13:15
Modified
2024-11-13 23:05
Severity ?
Summary
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C62D5AE-CDAF-4FB3-A27D-C7EB33701D9C",
              "versionEndExcluding": "3.1.2.1",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions \u003c V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions \u003c V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions \u003c V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en PP TeleControl Server Basic 1000 a 5000 V3.1 (6NH9910-0AA31-0AE1) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 256 a 1000 V3.1 (6NH9910-0AA31-0AD1) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 32 a 64 V3.1 (6NH9910-0AA31-0AF1) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 64 a 256 V3.1 (6NH9910-0AA31-0AC1) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), PP TeleControl Server Basic 8 a 32 V3.1 (6NH9910-0AA31-0AB1) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (Todas las versiones \u0026lt; V3.1.2.1 con redundancia configurada). El sistema afectado permite a los usuarios remotos enviar objetos manipulados con fines malintencionados. Debido a la deserializaci\u00f3n insegura del contenido proporcionado por el usuario por parte del software afectado, un atacante no autenticado podr\u00eda aprovechar esta vulnerabilidad enviando un objeto serializado manipulado con fines malintencionados. Esto podr\u00eda permitir al atacante ejecutar c\u00f3digo arbitrario en el dispositivo con privilegios de SYSTEM."
    }
  ],
  "id": "CVE-2024-44102",
  "lastModified": "2024-11-13T23:05:23.193",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "subConfidentialityImpact": "HIGH",
          "subIntegrityImpact": "HIGH",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-11-12T13:15:08.203",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-454789.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-502"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetOverview\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetOverview\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32872",
  "lastModified": "2025-08-19T15:04:01.980",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:19.303",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:58
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32823",
  "lastModified": "2025-08-19T14:58:00.760",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:08.120",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:11
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockBufferingSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockBufferingSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32856",
  "lastModified": "2025-08-19T15:11:52.910",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:16.023",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027MigrateDatabase\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"MigrateDatabase\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32871",
  "lastModified": "2025-08-19T15:04:10.483",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:18.943",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockProjectUserRights\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockProjectUserRights\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32832",
  "lastModified": "2025-08-19T15:23:11.530",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.963",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ImportConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"ImportConnectionVariables\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32838",
  "lastModified": "2025-08-19T15:22:55.340",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:11.590",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:58
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetProjects\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetProjects\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32825",
  "lastModified": "2025-08-19T14:58:13.053",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:08.717",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:58
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetActiveProjects\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u0027GetActiveProjects\u0027. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32826",
  "lastModified": "2025-08-19T14:58:21.053",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.060",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:54
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateConnectionVariables\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25909)"
    }
  ],
  "id": "CVE-2025-30002",
  "lastModified": "2025-08-19T14:54:04.807",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:05.107",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockOpcSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockOpcSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32854",
  "lastModified": "2025-08-19T15:12:05.700",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:15.660",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-01-25 14:29
Modified
2024-11-21 04:07
Summary
A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E31D80D0-A773-45F5-8155-43861100BC48",
              "versionEndExcluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic\u0027s port 8000/tcp could escalate his privileges and perform administrative operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic en versiones anteriores a la 3.1. Un atacante autenticado con una cuenta de privilegios bajos en el puerto 8000/tcp de TeleControl Server Basic podr\u00eda escalar sus privilegios y realizar operaciones administrativas."
    }
  ],
  "id": "CVE-2018-4836",
  "lastModified": "2024-11-21T04:07:33.153",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-01-25T14:29:00.380",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102897"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102904"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102897"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102904"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:57
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25912)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25912)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25912)"
    }
  ],
  "id": "CVE-2025-32475",
  "lastModified": "2025-08-19T14:57:25.477",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:07.820",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:48
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027RestoreFromBackup\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"RestoreFromBackup\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25923)"
    }
  ],
  "id": "CVE-2025-29905",
  "lastModified": "2025-08-19T14:48:46.397",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:04.817",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetUsers\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetUsers\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32842",
  "lastModified": "2025-08-19T15:22:43.477",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:12.577",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockGeneralSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockGeneralSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32847",
  "lastModified": "2025-08-19T15:12:58.470",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:14.090",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateLog\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"CreateLog\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32865",
  "lastModified": "2025-08-19T15:04:57.333",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:17.853",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetTraces\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetTraces\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32870",
  "lastModified": "2025-08-19T15:04:20.697",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:18.767",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockTcmSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockTcmSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32851",
  "lastModified": "2025-08-19T15:12:26.340",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:15.143",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockProjectCrossCommunications\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockProjectCrossCommunications\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32829",
  "lastModified": "2025-08-19T15:23:19.773",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.507",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:11
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockBufferingSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockBufferingSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32857",
  "lastModified": "2025-08-19T15:11:46.273",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:16.403",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateWebServerGatewaySettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a la V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateWebServerGatewaySettings\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32858",
  "lastModified": "2025-08-19T15:05:48.463",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:16.663",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-01-25 14:29
Modified
2024-11-21 04:07
Summary
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E31D80D0-A773-45F5-8155-43861100BC48",
              "versionEndExcluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic \u003c V3.1. An attacker with access to the TeleControl Server Basic\u0027s webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic en versiones anteriores a la 3.1. Un atacante con acceso al servidor web de Telecontrol Server Basic (puerto 80/tcp o 443/tcp) podr\u00eda provocar una denegaci\u00f3n de servicio (DoS) en el servidor web. Las dem\u00e1s funcionalidades de TeleControl Server Basic no se ven afectadas por la denegaci\u00f3n de servicio (DoS)."
    }
  ],
  "id": "CVE-2018-4837",
  "lastModified": "2024-11-21T04:07:33.270",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-01-25T14:29:00.427",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102819"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102904"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102819"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/102904"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockSmtpSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockSmtpSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32848",
  "lastModified": "2025-08-19T15:12:51.460",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:14.280",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:53
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ImportDatabase\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"ImportDatabase\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25924)"
    }
  ],
  "id": "CVE-2025-30030",
  "lastModified": "2025-08-19T14:53:49.510",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:05.417",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetLogs\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetLogs\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32866",
  "lastModified": "2025-08-19T15:04:48.203",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:18.020",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:52
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25917)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25917)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"CreateProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25917)"
    }
  ],
  "id": "CVE-2025-31351",
  "lastModified": "2025-08-19T14:52:44.720",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:06.500",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-08-27 07:15
Modified
2024-11-21 06:23
Summary
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:opcfoundation:local_discover_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD47A17-5E0C-4BCA-989C-C5CDEAC20A06",
              "versionEndExcluding": "1.04.402.463",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3BD1C40-AB88-4CB8-820E-C32C4AEBD455",
              "versionEndExcluding": "2022",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:2022:-:*:*:*:*:*:*",
              "matchCriteriaId": "D113B41E-4268-407B-A729-EBC9385D8943",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "298E8F34-346B-4FC5-8690-3F947F585552",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*",
              "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*",
              "matchCriteriaId": "AFBD6DDF-917C-44CC-A944-1945DC7AC9FB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F7BB505-A6B6-4200-9602-E4D348E407AB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
              "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_scada_runtime:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "772ECFF2-BB17-4B72-A570-18631521E147",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "975FC6E7-8FDB-4361-A691-44B26B0CBFD4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer."
    },
    {
      "lang": "es",
      "value": "En OPC Foundation Local Discovery Server (LDS) versiones anteriores a 1.04.402.463, unos atacantes remotos pueden causar una denegaci\u00f3n de servicio (DoS) mediante el env\u00edo de mensajes cuidadosamente dise\u00f1ados que conllevan a el Acceso a una Ubicaci\u00f3n de Memoria Despu\u00e9s del Final de un B\u00fafer."
    }
  ],
  "id": "CVE-2021-40142",
  "lastModified": "2024-11-21T06:23:38.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-27T07:15:08.630",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://opcfoundation.org/security-bulletins/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://opcfoundation.org/security-bulletins/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockTraceLevelSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockTraceLevelSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32863",
  "lastModified": "2025-08-19T15:05:12.893",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:17.527",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateConnectionVariablesWithImport\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateConnectionVariablesWithImport\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32834",
  "lastModified": "2025-08-19T15:23:06.823",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:10.260",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockTraceLevelSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockTraceLevelSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32862",
  "lastModified": "2025-08-19T15:05:20.543",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:17.367",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:58
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32824",
  "lastModified": "2025-08-19T14:58:07.553",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:08.377",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateBackup\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"CreateBackup\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32867",
  "lastModified": "2025-08-19T15:04:41.620",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:18.197",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockDatabaseSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockDatabaseSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32852",
  "lastModified": "2025-08-19T15:12:19.113",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:15.333",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:49
Severity ?
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027VerifyUser\u0027 method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.  (ZDI-CAN-25914)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a la V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"VerifyUser\". Esto podr\u00eda permitir que un atacante remoto no autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25914)"
    }
  ],
  "id": "CVE-2025-27539",
  "lastModified": "2025-08-19T14:49:14.680",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 9.3,
          "baseSeverity": "CRITICAL",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "LOW",
          "subConfidentialityImpact": "LOW",
          "subIntegrityImpact": "LOW",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:04.477",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockUser\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockUser\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32843",
  "lastModified": "2025-08-19T15:22:38.213",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:12.907",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:53
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25921)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateDatabaseSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25921)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateDatabaseSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25921)"
    }
  ],
  "id": "CVE-2025-30032",
  "lastModified": "2025-08-19T14:53:32.690",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:05.733",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetConnectionVariables\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32836",
  "lastModified": "2025-08-19T15:23:02.237",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:10.920",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockSmtpSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockSmtpSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32849",
  "lastModified": "2025-08-19T15:12:44.413",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:14.723",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:11
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockOpcSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockOpcSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32855",
  "lastModified": "2025-08-19T15:11:59.180",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:15.853",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateTraceLevelSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateTraceLevelSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32861",
  "lastModified": "2025-08-19T15:05:26.900",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:17.193",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockGateway\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockGateway\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32840",
  "lastModified": "2025-08-19T15:22:48.723",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:11.963",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:58
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ActivateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ActivateProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"ActivateProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32827",
  "lastModified": "2025-08-19T14:58:28.110",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:09.213",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockTcmSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockTcmSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32850",
  "lastModified": "2025-08-19T15:12:35.097",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:14.930",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:57
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'DeleteProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027DeleteProject\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"DeleteProject\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32822",
  "lastModified": "2025-08-19T14:57:34.740",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:07.973",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:13
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateGeneralSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateGeneralSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32845",
  "lastModified": "2025-08-19T15:13:08.250",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:13.513",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ImportCertificate\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"ImportCertificate\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32869",
  "lastModified": "2025-08-19T15:04:28.257",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:18.577",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:53
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25922)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateUsers\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25922)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateUsers\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25922)"
    }
  ],
  "id": "CVE-2025-30031",
  "lastModified": "2025-08-19T14:53:40.573",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:05.580",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateConnectionVariableArchivingBuffering\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateConnectionVariableArchivingBuffering\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32835",
  "lastModified": "2025-08-19T15:23:04.477",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:10.533",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetGateways\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetGateways\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32839",
  "lastModified": "2025-08-19T15:22:51.080",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:11.777",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:53
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateTcmSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateTcmSettings\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \u00abNT AUTHORITY\\NetworkService\u00bb. Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25920)"
    }
  ],
  "id": "CVE-2025-31343",
  "lastModified": "2025-08-19T14:53:23.430",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:06.000",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:52
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateGateways\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UpdateGateways\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25915)"
    }
  ],
  "id": "CVE-2025-31352",
  "lastModified": "2025-08-19T14:52:35.097",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:07.520",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-17 11:15
Modified
2025-08-19 14:48
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition.\r\nSuccessful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). El producto afectado no valida correctamente el campo de longitud en un mensaje serializado, que utiliza para determinar la cantidad de memoria que se asignar\u00e1 para la deserializaci\u00f3n. Esto podr\u00eda permitir que un atacante remoto no autenticado provoque que la aplicaci\u00f3n asigne cantidades excesivas de memoria y, posteriormente, genere una condici\u00f3n de denegaci\u00f3n de servicio parcial. Esta vulnerabilidad solo se puede explotar con \u00e9xito en configuraciones redundantes de Telecontrol Server Basic y solo si se interrumpe la conexi\u00f3n entre los servidores redundantes."
    }
  ],
  "id": "CVE-2025-29931",
  "lastModified": "2025-08-19T14:48:34.130",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 3.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 6.3,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "LOW",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-17T11:15:47.807",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-395348.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-130"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:12
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockDatabaseSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockDatabaseSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32853",
  "lastModified": "2025-08-19T15:12:13.713",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:15.497",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:49
Severity ?
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateTrace' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027CreateTrace\u0027 method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a la V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"CreateTrace\". Esto podr\u00eda permitir que un atacante remoto no autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25911)"
    }
  ],
  "id": "CVE-2025-27495",
  "lastModified": "2025-08-19T14:49:42.453",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 9.3,
          "baseSeverity": "CRITICAL",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "LOW",
          "subConfidentialityImpact": "LOW",
          "subIntegrityImpact": "LOW",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:04.310",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"GetSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32864",
  "lastModified": "2025-08-19T15:05:05.793",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:17.693",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:13
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockGeneralSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockGeneralSettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32846",
  "lastModified": "2025-08-19T15:13:03.163",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:13.810",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockWebServerGatewaySettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockWebServerGatewaySettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32860",
  "lastModified": "2025-08-19T15:05:34.153",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:17.020",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:49
Severity ?
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'Authenticate' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027Authenticate\u0027 method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a la V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"Authenticate\". Esto podr\u00eda permitir que un atacante remoto no autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25913)"
    }
  ],
  "id": "CVE-2025-27540",
  "lastModified": "2025-08-19T14:49:00.673",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 9.3,
          "baseSeverity": "CRITICAL",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "LOW",
          "subConfidentialityImpact": "LOW",
          "subIntegrityImpact": "LOW",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:04.630",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:52
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25918)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateBufferingSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25918)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateBufferingSettings\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \u00abNT AUTHORITY\\NetworkService\u00bb. Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25918)"
    }
  ],
  "id": "CVE-2025-31350",
  "lastModified": "2025-08-19T14:52:53.683",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:06.323",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:53
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateSmtpSettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a la V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateSmtpSettings\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \u00abNT AUTHORITY\\NetworkService\u00bb. Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25919)"
    }
  ],
  "id": "CVE-2025-31349",
  "lastModified": "2025-08-19T14:53:14.027",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:06.157",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:22
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027GetActiveConnectionVariables\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u0027GetActiveConnectionVariables\u0027. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32837",
  "lastModified": "2025-08-19T15:22:59.347",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:11.257",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:23
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockProjectUserRights\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockProjectUserRights\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32833",
  "lastModified": "2025-08-19T15:23:08.917",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:10.113",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:13
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UnlockUser\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"UnlockUser\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32844",
  "lastModified": "2025-08-19T15:13:12.793",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:13.337",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 04:46
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
Impacted products
Vendor Product Version
siemens simatic_cp443-1_opc_ua_firmware *
siemens simatic_cp443-1_opc_ua -
siemens simatic_et_200_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200_open_controller_cpu_1515sp_pc2 -
siemens simatic_ipc_diagmonitor_firmware *
siemens simatic_ipc_diagmonitor -
siemens simatic_net_pc_software_firmware *
siemens simatic_net_pc_software -
siemens simatic_rf188c_firmware *
siemens simatic_rf188c -
siemens simatic_rf600r_firmware *
siemens simatic_rf600r -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens opc_unified_architecture *
siemens simatic_s7-1500_software_controller *
siemens simatic_wincc_oa *
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_comfort *
siemens simatic_wincc_runtime_hsp_comfort *
siemens simatic_wincc_runtime_mobile *
siemens sinec-nms *
siemens sinec-nms 1.0
siemens sinema_server *
siemens sinumerik_opc_ua_server *
siemens telecontrol_server_basic *
siemens simatic_s7-1500f_firmware *
siemens simatic_s7-1500f -
siemens simatic_s7-1500s_firmware *
siemens simatic_s7-1500s -
siemens simatic_s7-1500t_firmware *
siemens simatic_s7-1500t -
siemens simatic_hmi_comfort_outdoor_panels_firmware *
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D0780D2-8892-490E-9C38-6D1516EBCA76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47272AD2-1D05-419E-A6BE-8836DF69FF82",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB5AE88-04E5-467E-85E5-D3C0DDA2B21F",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF0944C4-8FD7-4B00-85B7-6DB430EAA884",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91371CD0-EBDF-43C5-A262-A46E1C343716",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5E06833-4C26-40AC-B6CF-F7D1322462D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77022802-113F-42E7-8FBF-C47BB50E8DA7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7A00F5A-9B28-45FF-8549-290302939DFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9523EC09-36C9-41E1-A485-C75819A2DB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "065D2218-EA10-410E-A49A-C9A259469421",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6230C5B0-2F36-4C94-BA28-D36170952423",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "054D17CD-74AF-473E-A3BC-7B69DFB1C04B",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B74D88E-E8D7-4AA9-8B54-CC833E26CEB4",
              "versionEndExcluding": "3.15-p018",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9AE946B-D532-4CEB-B109-C8B951B61E49",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49D722B2-948B-4F11-AD36-E1378BB40403",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "455411C4-037C-47BF-9BD6-AC7F9C2D30F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED63145-9082-4346-871B-DF0A6F91E7F0",
              "versionEndExcluding": "1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec-nms:1.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "1F6F05DC-0FBA-4D25-A2E6-06D873B3DFAA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E31B88B-E743-4DFD-996B-154F7F48C510",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2ECBEF2-9B1A-49F8-9850-0AF09BF71ED7",
              "versionEndExcluding": "3.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58CCDA0F-F657-4AF8-BE53-A3993C0280B3",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3F162D0-998E-4EC9-BA59-D9B47B07EF69",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C47ADAD6-2DDE-49EF-864B-CC9448399E7B",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "DE71784C-012F-40EC-82E2-3BE8589F00DC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "C5A35FDE-C76F-430E-BD15-373F9F30FED5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "37A6344F-CB58-4CFA-A971-395BFB3FF02B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "E949961E-320A-4E25-A0CA-5EBC7DA0AD9D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "A390DCB7-4511-4931-A34B-BF6A9B84370D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "FF5136A8-130C-4121-A250-B4DE5883239E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "862B1996-202B-42DF-A7DA-D01CD43C4AB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "7AFD3E4C-7125-4FB5-991F-76A31AD61BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "71172F82-C9B6-4DEC-ADCC-F455E72936CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "A8CA985F-3678-46F4-BE2E-BDBCCD1BC0FE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "1A28CC05-0CEA-4221-83CE-4029726F60E0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "5D612CB7-45A0-44AC-BB96-12AFE2B14CE8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "7B0FAB4F-7D95-4FC0-AF59-CCEDC6E22DC3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "5C925AE3-7262-4DDD-803D-D871A66CD2B2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "E64DEED6-7E6F-4E79-BA4D-2B2E43B2B97D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "9429BA23-CB76-4574-B7F8-530882CF704A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "3794C871-098D-428F-89EA-ADDEFD4E4A86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "386F501D-5C7D-4336-A39D-31B12C5BCB56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 443-1 OPC UA (todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones anteriores a V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026amp; 15\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15. 1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a V15.1 Upd 4), SIMATIC IPC DiagMonitor (Todas las versiones anteriores a V5.1. 3), SIMATIC NET PC Software V13 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC RF188C (Todas las versiones anteriores a V1. 1.0), familia SIMATIC RF600R (Todas las versiones anteriores a V3.2.1), familia de CPUs SIMATIC S7-1500 (incluidas las CPUs ET200 relacionadas y las variantes SIPLUS) (Todas las versiones posteriores o iguales a V2.5 anteriores a V2.6.1), SIMATIC S7-1500 Software Controller (Todas las versiones entre V2.5 (incluida) y V2.7 (excluida)), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 15 P018), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V15.1 Upd 4), SINEC NMS (Todas las versiones anteriores a V1.0 SP1), SINEMA Server (Todas las versiones anteriores a V14 SP2), SINUMERIK OPC UA Server (Todas las versiones anteriores a V2.1), TeleControl Server Basic (Todas las versiones anteriores a V3.1.1). Los paquetes de red especialmente dise\u00f1ados que se env\u00edan a los dispositivos afectados en el puerto 4840/tcp podr\u00edan permitir a un atacante remoto no autenticado provocar una condici\u00f3n de denegaci\u00f3n de servicio de la comunicaci\u00f3n OPC o bloquear el dispositivo. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad de la comunicaci\u00f3n OPC"
    }
  ],
  "id": "CVE-2019-6575",
  "lastModified": "2024-11-21T04:46:43.960",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-17T14:29:03.760",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-248"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-755"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:04
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027ExportCertificate\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"ExportCertificate\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32868",
  "lastModified": "2025-08-19T15:04:35.243",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:18.390",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 15:05
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027LockWebServerGatewaySettings\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \"LockWebServerGatewaySettings\". Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada."
    }
  ],
  "id": "CVE-2025-32859",
  "lastModified": "2025-08-19T15:05:41.453",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:16.837",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2025-04-16 18:16
Modified
2025-08-19 14:53
Summary
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectConnections' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)
Impacted products
Vendor Product Version
siemens telecontrol_server_basic *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A439C0E-7853-489C-93A5-40596265F6D0",
              "versionEndExcluding": "3.1.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateProjectConnections\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicaci\u00f3n afectada es vulnerable a la inyecci\u00f3n de SQL mediante el m\u00e9todo interno \u00abUpdateProjectConnections\u00bb. Esto podr\u00eda permitir que un atacante remoto autenticado eluda los controles de autorizaci\u00f3n, lea y escriba en la base de datos de la aplicaci\u00f3n y ejecute c\u00f3digo con permisos \u00abNT AUTHORITY\\NetworkService\u00bb. Para que el ataque tenga \u00e9xito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versi\u00f3n vulnerable de la aplicaci\u00f3n afectada. (ZDI-CAN-25910)"
    }
  ],
  "id": "CVE-2025-30003",
  "lastModified": "2025-08-19T14:53:58.180",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-04-16T18:16:05.260",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}