Vulnerabilites related to abb - txpert_hub_coretec_4
CVE-2023-2625 (GCVE-0-2023-2625)
Vulnerability from cvelistv5
Published
2023-06-28 16:15
Modified
2024-12-04 20:57
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Hitachi Energy | TXpert Hub CoreTec 4 |
Version: TXpert Hub CoreTec 4 version 2.0.* Version: TXpert Hub CoreTec 4 version 2.1.* Version: TXpert Hub CoreTec 4 version 2.2.* Version: TXpert Hub CoreTec 4 version 2.3.* Version: TXpert Hub CoreTec 4 version 2.4.* |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T06:26:09.908Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000163\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-2625", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-04T20:56:20.897497Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-04T20:57:56.402Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "TXpert Hub CoreTec 4", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "TXpert Hub CoreTec 4 version 2.0.*" }, { "status": "affected", "version": "TXpert Hub CoreTec 4 version 2.1.*" }, { "status": "affected", "version": "TXpert Hub CoreTec 4 version 2.2.*" }, { "status": "affected", "version": "TXpert Hub CoreTec 4 version 2.3.*" }, { "status": "affected", "version": "TXpert Hub CoreTec 4 version 2.4.*" }, { "status": "unaffected", "version": "TXpert Hub CoreTec 4 version 3.0.1" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system." } ], "value": "A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-28T16:15:46.529Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000163\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The vulnerability is remediated in\u0026nbsp;TXpert Hub CoreTec 4 version 3.0.1." } ], "value": "The vulnerability is remediated in\u00a0TXpert Hub CoreTec 4 version 3.0.1." } ], "source": { "discovery": "UNKNOWN" }, "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nApply mitigation as described in the cybersecurity advisory Mitigation Factors/Workarounds Section.\n\n\u003cbr\u003e" } ], "value": "\nApply mitigation as described in the cybersecurity advisory Mitigation Factors/Workarounds Section.\n\n\n" } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2023-2625", "datePublished": "2023-06-28T16:15:46.529Z", "dateReserved": "2023-05-10T10:31:57.900Z", "dateUpdated": "2024-12-04T20:57:56.402Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2023-06-28 17:15
Modified
2024-11-21 07:58
Severity ?
9.0 (Critical) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
abb | txpert_hub_coretec_4_firmware | * | |
abb | txpert_hub_coretec_4 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:txpert_hub_coretec_4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65472456-E16E-454B-86D3-84F2469D3809", "versionEndExcluding": "3.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:txpert_hub_coretec_4:-:*:*:*:*:*:*:*", "matchCriteriaId": "9597F443-3693-451E-9EDA-66092ADB78E3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system." } ], "id": "CVE-2023-2625", "lastModified": "2024-11-21T07:58:57.377", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 6.0, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-28T17:15:10.627", "references": [ { "source": "cybersecurity@hitachienergy.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000163\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000163\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }