Vulnerabilites related to bosch - video_streaming_gateway
Vulnerability from fkie_nvd
Published
2020-02-07 20:15
Modified
2024-11-21 05:36
Severity ?
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Summary
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
References
▶ | URL | Tags | |
---|---|---|---|
psirt@bosch.com | https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html | Patch, Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "6982F24B-1DB5-4331-9418-618A0E7C0AA6", "versionEndIncluding": "6.42.10", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "D132FF92-04FE-4036-A540-2AF7DFF8A7BF", "versionEndIncluding": "6.43.0023", "versionStartIncluding": "6.43", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "1651176D-7EBE-4CDA-8C96-0767E4458E47", "versionEndIncluding": "6.44.022", "versionStartIncluding": "6.44", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "A556E28A-8323-4990-AF87-57CAF5C4D858", "versionEndIncluding": "6.45.08", "versionStartIncluding": "6.45", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9754B-930B-4C1C-A2BA-6BF356AD29E3", "versionEndIncluding": "3.62.0019", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "114BF1E1-4E81-42C3-A563-7C4A523312A4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_5000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D21A7415-BC5C-438A-8003-B733C9C954E9", "versionEndIncluding": "3.80.0039", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB0DE1C9-D3C0-49BF-9FFD-B765F9AF6691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "6982F24B-1DB5-4331-9418-618A0E7C0AA6", "versionEndIncluding": "6.42.10", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "D132FF92-04FE-4036-A540-2AF7DFF8A7BF", "versionEndIncluding": "6.43.0023", "versionStartIncluding": "6.43", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "1651176D-7EBE-4CDA-8C96-0767E4458E47", "versionEndIncluding": "6.44.022", "versionStartIncluding": "6.44", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "A556E28A-8323-4990-AF87-57CAF5C4D858", "versionEndIncluding": "6.45.08", "versionStartIncluding": "6.45", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EE760B-9B65-49A3-92E5-93880C58A628", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "6982F24B-1DB5-4331-9418-618A0E7C0AA6", "versionEndIncluding": "6.42.10", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "D132FF92-04FE-4036-A540-2AF7DFF8A7BF", "versionEndIncluding": "6.43.0023", "versionStartIncluding": "6.43", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "1651176D-7EBE-4CDA-8C96-0767E4458E47", "versionEndIncluding": "6.44.022", "versionStartIncluding": "6.44", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "A556E28A-8323-4990-AF87-57CAF5C4D858", "versionEndIncluding": "6.45.08", "versionStartIncluding": "6.45", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "10D23E90-110B-4ADC-8417-CD0149D126D2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "6982F24B-1DB5-4331-9418-618A0E7C0AA6", "versionEndIncluding": "6.42.10", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "D132FF92-04FE-4036-A540-2AF7DFF8A7BF", "versionEndIncluding": "6.43.0023", "versionStartIncluding": "6.43", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "1651176D-7EBE-4CDA-8C96-0767E4458E47", "versionEndIncluding": "6.44.022", "versionStartIncluding": "6.44", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "A556E28A-8323-4990-AF87-57CAF5C4D858", "versionEndIncluding": "6.45.08", "versionStartIncluding": "6.45", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_all-in-one_5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "7075A014-A297-4E41-81D8-2535BC2BD4E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall." }, { "lang": "es", "value": "Una Falta de Autenticaci\u00f3n para la Funci\u00f3n Cr\u00edtica en Bosch Video Streaming Gateway (VSG) permite a un atacante remoto no autenticado recuperar y establecer datos de configuraci\u00f3n arbitrarios de Video Streaming Gateway. Un ataque con \u00e9xito puede impactar la confidencialidad y la disponibilidad de los datos de video en vivo y grabados de todas las c\u00e1maras configuradas para ser controladas por el VSG, as\u00ed como el almacenamiento de grabaci\u00f3n asociado con el VSG. Esto afecta a Bosch Video Streaming Gateway versiones 6.45 anteriores a 6.45.08 incluy\u00e9ndola, 6.44 anteriores a 6.44.022 incluy\u00e9ndola, 6.43 anteriores a 6.43.0023 incluy\u00e9ndola y 6.42.10 y anteriores. Esto afecta a Bosch DIVAR IP 3000, DIVAR IP 7000 y DIVAR IP all-in-one 5000, si se instala una versi\u00f3n vulnerable de VSG con BVMS. Esto afecta a Bosch DIVAR IP 2000 anteriores a 3.62.0019 incluy\u00e9ndola y DIVAR IP 5000 anteriores a 3.80.0039 incluy\u00e9ndola, si el puerto 8023 correspondiente ha sido abierto en el firewall del dispositivo." } ], "id": "CVE-2020-6769", "lastModified": "2024-11-21T05:36:09.790", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-02-07T20:15:35.507", "references": [ { "source": "psirt@bosch.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-03-25 16:15
Modified
2024-11-21 05:36
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
bosch | video_streaming_gateway | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "78EDF599-23DF-434A-B1EF-D26A948C6481", "versionEndIncluding": "6.45.10", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from." }, { "lang": "es", "value": "Llamar un ejecutable mediante un Elemento de Ruta de B\u00fasqueda no Controlada en el instalador de Bosch Video Streaming Gateway versiones hasta 6.45.10 incluy\u00e9ndola, permite a un atacante ejecutar c\u00f3digo arbitrario en el sistema de la v\u00edctima.\u0026#xa0;Un requisito previo es que la v\u00edctima sea enga\u00f1ada para colocar un exe malicioso en el mismo directorio desde el que se inicia el instalador" } ], "id": "CVE-2020-6790", "lastModified": "2024-11-21T05:36:11.420", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.9, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-25T16:15:13.867", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-427" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-427" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-05-29 19:29
Modified
2024-11-21 04:47
Severity ?
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B5A626A-B735-4E0B-8BAC-0A26A02D6599", "versionEndIncluding": "3.7", "versionStartIncluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*", "matchCriteriaId": "EFBF448F-005B-48FF-B796-DBC8EAA35323", "versionEndExcluding": "1.7.6.079", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B9DD276-15C0-4942-8899-553F7C190320", "versionEndIncluding": "9.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "D92BA2E1-8554-4F13-938D-855BC33A59C9", "versionEndIncluding": "4.4", "versionStartIncluding": "2.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*", "matchCriteriaId": "8585CAE6-8A82-4338-A510-BB1798AC0BE3", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*", "matchCriteriaId": "05B6AD6C-8FCC-473C-9D9A-91EA6C9A8E3E", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*", "matchCriteriaId": "8E219B63-2423-4D01-BDA9-8128B5E0DC24", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "4100A710-A356-4D54-BADE-F6C16947C3F0", "versionEndExcluding": "6.10", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "526B56A8-3106-44C1-8C77-B22995A98C86", "versionEndExcluding": "3.71.0032", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "31523A17-95B3-42D6-B176-1814A91239C9", "versionEndExcluding": "3.81.0048", "versionStartIncluding": "3.81", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*", "matchCriteriaId": "F421BFB6-5448-4B86-AEB6-062682F56C10", "versionEndExcluding": "6.32.0099", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAA61FF3-D717-4A33-B175-E418B11A0BEE", "versionEndExcluding": "6.43.0023", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "8CD3166A-2B9C-4641-803C-BC4EBEF035F1", "versionEndExcluding": "6.45.0008", "versionStartIncluding": "6.45", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC039957-2F53-4080-AB7B-1E2AA4F81790", "versionEndExcluding": "0380.037", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*", "matchCriteriaId": "BC890021-B200-4743-AB51-03BDC9CB1351", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "FAE1D3ED-FE23-4F3B-AE75-2FFBDEF5FDAF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABB194FD-9D50-4420-925F-48E4B2D0C2E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0062D5B-DF47-47AB-A6E7-B00BEA2FBA1E", "versionEndExcluding": "038.037", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFAEE79-2B7C-4F74-B663-F49F2606AF41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7731276E-38B9-4B01-B4A3-092A49150B9A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*", "matchCriteriaId": "C8FDECC6-46D7-4EAF-9CBC-06D2F18AADA5", "vulnerable": false }, { "criteria": "cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*", "matchCriteriaId": "ED2FF548-939C-4F10-A3E7-02DF342A35B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*", "matchCriteriaId": "DA449D4D-8AF0-4792-A9CA-8195A4E0082B", "vulnerable": true }, { "criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*", "matchCriteriaId": "DE6EFC6A-351D-4571-A1F7-1E6AC0B77B22", "vulnerable": true }, { "criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*", "matchCriteriaId": "A6B97D59-8692-449F-BA59-C2C2F3E0FDDB", "vulnerable": true }, { "criteria": "cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*", "matchCriteriaId": "A3C2E4AA-B871-4B0B-8BD0-8D5440BE8144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "50324AEF-BF89-4AAC-B467-FCF87796AB01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface." }, { "lang": "es", "value": "Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y anteriores de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). La vulnerabilidad potencialmente permite la ejecuci\u00f3n no autorizada de c\u00f3digo en el sistema por medio de la interfaz de red." } ], "id": "CVE-2019-6957", "lastModified": "2024-11-21T04:47:18.127", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-05-29T19:29:00.657", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-18 13:15
Modified
2024-11-21 08:02
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:monitor_wall:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BAF5133-10CA-4385-867E-AA540A4536DD", "versionEndIncluding": "10.00.0164", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:videojet_decoder_7513_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E6615DD-5B39-459D-B6B6-4B3279D5956A", "versionEndIncluding": "10.40.0055", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:videojet_decoder_7513:-:*:*:*:*:*:*:*", "matchCriteriaId": "A96A7B0B-4C65-412E-8AB0-BD6098548598", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:videojet_decoder_7523_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CEC397B1-12A4-44B7-9BC1-78947B0D042E", "versionEndIncluding": "10.40.0055", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:videojet_decoder_7523:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C771252-5D00-4B5B-B8D2-841F842D36B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9B820C5-8984-4204-A9F5-90D3FE671657", "versionEndIncluding": "04.10.0079", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C4233F9-FF75-476D-991B-5A030AC99CC7", "versionEndIncluding": "8.1.2.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D5AC8FA-A1DB-4749-960A-E378B820F0C0", "versionEndIncluding": "9.0.0.178", "versionStartIncluding": "9.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation." }, { "lang": "es", "value": "Un manejo inadecuado de una solicitud API con formato incorrecto a un servidor API en los productos de software Bosch BT puede permitir que un atacante no autenticado provoque una situaci\u00f3n de denegaci\u00f3n de servicio (DoS)." } ], "id": "CVE-2023-32230", "lastModified": "2024-11-21T08:02:56.827", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-12-18T13:15:06.790", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-703" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2023-32230 (GCVE-0-2023-32230)
Vulnerability from cvelistv5
Published
2023-12-18 12:58
Modified
2024-08-02 15:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Summary
An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Bosch | Video Recording Manager |
Version: 0 < |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:10:24.221Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Video Recording Manager", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "04.10.0079", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "Video Streaming Gateway", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "8.1.2.2", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThanOrEqual": "9.0.0.178", "status": "affected", "version": "9.0.0", "versionType": "custom" } ] }, { "product": "Monitorwall", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "10.00.0164", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "VJD-7513", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "10.40.0055", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "VJD-7523", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "10.40.0055", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "An improper handling of a malformed API request to an API server in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-703", "description": "CWE-703 Improper Check or Handling of Exceptional Conditions", "lang": "en-US" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-18T12:58:08.690Z", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html", "tags": [ "vendor-advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" } ] } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2023-32230", "datePublished": "2023-12-18T12:58:08.690Z", "dateReserved": "2023-05-04T21:01:16.508Z", "dateUpdated": "2024-08-02T15:10:24.221Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-6790 (GCVE-0-2020-6790)
Vulnerability from cvelistv5
Published
2021-03-25 15:53
Modified
2024-09-17 04:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-427 - Uncontrolled Search Path Element
Summary
Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim's system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Bosch | Video Streaming Gateway |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:11:05.015Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Video Streaming Gateway", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "6.45.10", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Dhiraj Mishra" } ], "datePublic": "2021-03-24T00:00:00", "descriptions": [ { "lang": "en", "value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-427", "description": "CWE-427 Uncontrolled Search Path Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-25T15:53:57", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html" } ], "source": { "advisory": "BOSCH-SA-835563-BT", "discovery": "EXTERNAL" }, "title": "Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@bosch.com", "DATE_PUBLIC": "2021-03-24", "ID": "CVE-2020-6790", "STATE": "PUBLIC", "TITLE": "Uncontrolled Search Path Element in Bosch Video Streaming Gateway Installer" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Video Streaming Gateway", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "6.45.10" } ] } } ] }, "vendor_name": "Bosch" } ] } }, "credit": [ { "lang": "eng", "value": "Dhiraj Mishra" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Calling an executable through an Uncontrolled Search Path Element in the Bosch Video Streaming Gateway installer up to and including version 6.45.10 potentially allows an attacker to execute arbitrary code on a victim\u0027s system. A prerequisite is that the victim is tricked into placing a malicious exe in the same directory where the installer is started from." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-427 Uncontrolled Search Path Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html", "refsource": "CONFIRM", "url": "https://psirt.bosch.com/security-advisories/bosch-sa-835563-bt.html" } ] }, "source": { "advisory": "BOSCH-SA-835563-BT", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2020-6790", "datePublished": "2021-03-25T15:53:57.342668Z", "dateReserved": "2020-01-10T00:00:00", "dateUpdated": "2024-09-17T04:25:29.649Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from cvelistv5
Published
2019-05-29 18:55
Modified
2024-09-16 16:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.396Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2019-04-04T00:00:00", "descriptions": [ { "lang": "en", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-05-29T18:55:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ], "solutions": [ { "lang": "en", "value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory." } ], "source": { "discovery": "UNKNOWN" }, "title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems", "x_generator": { "engine": "Vulnogram 0.0.6" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2019-04-04T22:00:00.000Z", "ID": "CVE-2019-6957", "STATE": "PUBLIC", "TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface." } ] }, "generator": { "engine": "Vulnogram 0.0.6" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf", "refsource": "CONFIRM", "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ] }, "solution": [ { "lang": "en", "value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory." } ], "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-6957", "datePublished": "2019-05-29T18:55:20.387906Z", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-09-16T16:38:39.411Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-6769 (GCVE-0-2020-6769)
Vulnerability from cvelistv5
Published
2020-02-07 19:57
Modified
2024-09-16 21:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Bosch | DIVAR IP 2000 |
Version: unspecified < |
||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:11:04.658Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DIVAR IP 2000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "3.62.0019", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "DIVAR IP 5000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "3.80.0039", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "Video Streaming Gateway", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "6.45.08", "status": "affected", "version": "6.45", "versionType": "custom" }, { "lessThanOrEqual": "6.44.0030", "status": "affected", "version": "6.44", "versionType": "custom" }, { "lessThanOrEqual": "6.43.0023", "status": "affected", "version": "6.43", "versionType": "custom" }, { "lessThanOrEqual": "6.42.10", "status": "affected", "version": "6.42 and older", "versionType": "custom" } ] }, { "product": "DIVAR IP 3000", "vendor": "Bosch", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "DIVAR IP 7000", "vendor": "Bosch", "versions": [ { "status": "affected", "version": "All" } ] }, { "product": "DIVAR IP all-in-one 5000", "vendor": "Bosch", "versions": [ { "status": "affected", "version": "All" } ] } ], "datePublic": "2020-01-29T00:00:00", "descriptions": [ { "lang": "en", "value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-07T19:57:12", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html" } ], "source": { "advisory": "BOSCH-SA-260625-BT", "discovery": "INTERNAL" }, "title": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@bosch.com", "DATE_PUBLIC": "2020-01-29T13:00:00.000Z", "ID": "CVE-2020-6769", "STATE": "PUBLIC", "TITLE": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DIVAR IP 2000", "version": { "version_data": [ { "configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed", "version_affected": "\u003c=", "version_value": "3.62.0019" } ] } }, { "product_name": "DIVAR IP 5000", "version": { "version_data": [ { "configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed", "version_affected": "\u003c=", "version_value": "3.80.0039" } ] } }, { "product_name": "Video Streaming Gateway", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "6.45", "version_value": "6.45.08" }, { "version_affected": "\u003c=", "version_name": "6.44", "version_value": "6.44.0030" }, { "version_affected": "\u003c=", "version_name": "6.43", "version_value": "6.43.0023" }, { "version_affected": "\u003c=", "version_name": "6.42 and older", "version_value": "6.42.10" } ] } }, { "product_name": "DIVAR IP 3000", "version": { "version_data": [ { "configuration": "vulnerable VSG version installed", "version_affected": "=", "version_value": "All" } ] } }, { "product_name": "DIVAR IP 7000", "version": { "version_data": [ { "configuration": "vulnerable VSG version installed", "version_affected": "=", "version_value": "All" } ] } }, { "product_name": "DIVAR IP all-in-one 5000", "version": { "version_data": [ { "configuration": "vulnerable VSG version installed", "version_affected": "=", "version_value": "All" } ] } } ] }, "vendor_name": "Bosch" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306 Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html", "refsource": "CONFIRM", "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html" } ] }, "source": { "advisory": "BOSCH-SA-260625-BT", "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2020-6769", "datePublished": "2020-02-07T19:57:12.914579Z", "dateReserved": "2020-01-10T00:00:00", "dateUpdated": "2024-09-16T21:03:26.539Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }