Improper Protection of Physical Side Channels
The device does not contain sufficient protection mechanisms to prevent physical side channels from exposing sensitive information due to patterns in physically observable phenomena such as variations in power consumption, electromagnetic emissions (EME), or acoustic emissions.
CVE-2023-6258 (GCVE-0-2023-6258)
Vulnerability from cvelistv5
- CWE-1300 - Improper Protection of Physical Side Channels
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Vendor | Product | Version | ||
---|---|---|---|---|
► | n/a | pkcs11-provider | ||
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:28:20.354Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "RHBZ#2251062", "tags": [ "issue-tracking", "x_refsource_REDHAT", "x_transferred" ], "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2251062" }, { "tags": [ "x_transferred" ], "url": "https://github.com/latchset/pkcs11-provider/pull/308" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-6258", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-01-31T15:54:56.761262Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-17T21:29:17.985Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "pkcs11-provider", "vendor": "n/a", "versions": [ { "status": "unaffected", "version": "0.2" } ] }, { "collectionURL": "https://packages.fedoraproject.org/", "defaultStatus": "affected", "packageName": "pkcs11-provider", "product": "Fedora", "vendor": "Fedora" } ], "datePublic": "2023-11-22T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "A security vulnerability has been identified in the pkcs11-provider, which is associated with Public-Key Cryptography Standards (PKCS#11). If exploited successfully, this vulnerability could result in a Bleichenbacher-like security flaw, potentially enabling a side-channel attack on PKCS#1 1.5 decryption." } ], "metrics": [ { "other": { "content": { "namespace": "https://access.redhat.com/security/updates/classification/", "value": "Moderate" }, "type": "Red Hat severity rating" } }, { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1300", "description": "Improper Protection of Physical Side Channels", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-08T18:05:32.581Z", "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749", "shortName": "redhat" }, "references": [ { "name": "RHBZ#2251062", "tags": [ "issue-tracking", "x_refsource_REDHAT" ], "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2251062" }, { "url": "https://github.com/latchset/pkcs11-provider/pull/308" } ], "timeline": [ { "lang": "en", "time": "2023-11-22T00:00:00+00:00", "value": "Reported to Red Hat." }, { "lang": "en", "time": "2023-11-22T00:00:00+00:00", "value": "Made public." } ], "title": "Pkcs11-provider: side-channel proofing pkcs#1 1.5 paths", "x_redhatCweChain": "CWE-1300: Improper Protection of Physical Side Channels" } }, "cveMetadata": { "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749", "assignerShortName": "redhat", "cveId": "CVE-2023-6258", "datePublished": "2024-01-30T16:55:18.733Z", "dateReserved": "2023-11-22T16:30:53.153Z", "dateUpdated": "2025-06-17T21:29:17.985Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Mitigation
Phase: Architecture and Design
Description:
- Apply blinding or masking techniques to implementations of cryptographic algorithms.
Mitigation
Phase: Implementation
Description:
- Add shielding or tamper-resistant protections to the device to increase the difficulty of obtaining measurements of the side-channel.
CAPEC-189: Black Box Reverse Engineering
An adversary discovers the structure, function, and composition of a type of computer software through black box analysis techniques. 'Black Box' methods involve interacting with the software indirectly, in the absence of direct access to the executable object. Such analysis typically involves interacting with the software at the boundaries of where the software interfaces with a larger execution environment, such as input-output vectors, libraries, or APIs. Black Box Reverse Engineering also refers to gathering physical side effects of a hardware device, such as electromagnetic radiation or sounds.
CAPEC-699: Eavesdropping on a Monitor
An Adversary can eavesdrop on the content of an external monitor through the air without modifying any cable or installing software, just capturing this signal emitted by the cable or video port, with this the attacker will be able to impact the confidentiality of the data without being detected by traditional security tools