CWE-1329
Reliance on Component That is Not Updateable
The product contains a component that cannot be updated or patched in order to remove vulnerabilities or significant bugs.
CVE-2021-38398 (GCVE-0-2021-38398)
Vulnerability from cvelistv5
Published
2021-10-04 17:35
Modified
2024-09-16 17:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Boston Scientific | ZOOM LATITUDE |
Version: Model 3120 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:37:16.493Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ZOOM LATITUDE", "vendor": "Boston Scientific", "versions": [ { "status": "affected", "version": "Model 3120" } ] } ], "credits": [ { "lang": "en", "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices and reported them to Boston Scientific." } ], "datePublic": "2021-09-30T00:00:00", "descriptions": [ { "lang": "en", "value": "The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1329", "description": "CWE-1329", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-04T17:35:06", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01" } ], "source": { "advisory": "ICSMA-21-273-01", "defect": [ "CWE-1329" ], "discovery": "EXTERNAL" }, "title": "Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude", "workarounds": [ { "lang": "en", "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security, the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2021-09-30T21:02:00.000Z", "ID": "CVE-2021-38398", "STATE": "PUBLIC", "TITLE": "Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ZOOM LATITUDE", "version": { "version_data": [ { "version_value": "Model 3120" } ] } } ] }, "vendor_name": "Boston Scientific" } ] } }, "credit": [ { "lang": "eng", "value": "Endres Puschner - Max Planck Institute for Security and Privacy, Bochum, Christoph Saatjohann - FH M\u00fcnster University of Applied Sciences, Christian Dresen - FH M\u00fcnster University of Applied Sciences, and Markus Willing - University of Muenster, discovered these issues as part of broader academic research of cardiac devices and reported them to Boston Scientific." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-1329" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-273-01" } ] }, "source": { "advisory": "ICSMA-21-273-01", "defect": [ "CWE-1329" ], "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "Boston Scientific is in the process of transitioning all users to a replacement programmer with enhanced security, the LATITUDE Programming System, Model 3300. Boston Scientific will not issue a product update to address the identified vulnerabilities in the ZOOM LATITUDE Programming System, Model 3120." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2021-38398", "datePublished": "2021-10-04T17:35:06.578644Z", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-09-16T17:58:22.688Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-34381 (GCVE-0-2022-34381)
Vulnerability from cvelistv5
Published
2024-02-02 15:30
Modified
2024-08-03 09:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1329 - Reliance on Component That is Not Updateable
Summary
Dell BSAFE SSL-J version 7.0 and all versions prior to 6.5, and Dell BSAFE Crypto-J versions prior to 6.2.6.1 contain an unmaintained third-party component vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to the compromise of the impacted system. This is a Critical vulnerability and Dell recommends customers to upgrade at the earliest opportunity.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Dell | Dell BSAFE Crypto-J |
Version: 0 ≤ |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2022-34381", "options": [ { "Exploitation": "None" }, { "Automatable": "Yes" }, { "Technical Impact": "Total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-20T04:00:11.570842Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:15:49.869Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-03T09:07:16.247Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000203278/dsa-2022-208-dell-bsafe-ssl-j-6-5-and-7-1-and-dell-bsafe-crypto-j-6-2-6-1-and-7-0-security-vulnerability" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Dell BSAFE Crypto-J", "vendor": "Dell", "versions": [ { "lessThan": "6.2.6.1", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Dell BSAFE SSL-J", "vendor": "Dell", "versions": [ { "status": "affected", "version": "7.0" }, { "lessThan": "6.5", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "datePublic": "2022-09-12T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell BSAFE SSL-J version 7.0 and all versions prior to 6.5, and Dell BSAFE Crypto-J versions prior to 6.2.6.1 contain an unmaintained third-party component vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to the compromise of the impacted system. This is a Critical vulnerability and Dell recommends customers to upgrade at the earliest opportunity.\u003c/span\u003e\n\n" } ], "value": "\nDell BSAFE SSL-J version 7.0 and all versions prior to 6.5, and Dell BSAFE Crypto-J versions prior to 6.2.6.1 contain an unmaintained third-party component vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to the compromise of the impacted system. This is a Critical vulnerability and Dell recommends customers to upgrade at the earliest opportunity.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1329", "description": "CWE-1329: Reliance on Component That is Not Updateable", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-05T16:54:29.967Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000203278/dsa-2022-208-dell-bsafe-ssl-j-6-5-and-7-1-and-dell-bsafe-crypto-j-6-2-6-1-and-7-0-security-vulnerability" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2022-34381", "datePublished": "2024-02-02T15:30:23.697Z", "dateReserved": "2022-06-23T18:55:17.089Z", "dateUpdated": "2024-08-03T09:07:16.247Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Mitigation
Phase: Requirements
Description:
- Specify requirements that each component should be updateable, including ROM, firmware, etc.
Mitigation
Phase: Architecture and Design
Description:
- Design the product to allow for updating of its components. Include the external infrastructure that might be necessary to support updates, such as distribution servers.
Mitigation
Phases: Architecture and Design, Implementation
Description:
- With hardware, support patches that can be programmed in-field or during manufacturing through hardware fuses. This feature can be used for limited patching of devices after shipping, or for the next batch of silicon devices manufactured, without changing the full device ROM.
Mitigation
Phase: Implementation
Description:
- Implement the necessary functionality to allow each component to be updated.