Vulnerabilites related to Axis Communications AB - AXIS Device Manager
CVE-2025-30024 (GCVE-0-2025-30024)
Vulnerability from cvelistv5
Published
2025-07-11 06:03
Modified
2025-07-11 16:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-295 - Improper Certificate Validation
Summary
The communication protocol used between client
and server had a flaw that could be leveraged to execute a man in the middle attack.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Axis Communications AB | AXIS Device Manager |
Version: <5.32 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-30024", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-07-11T16:22:14.304334Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-07-11T16:28:42.727Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AXIS Device Manager", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c5.32" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noam Moshe of Claroty Team82" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The communication protocol used between client\nand server had a flaw that could be leveraged to execute a man in the middle attack.\n\n\n\u003cbr\u003e" } ], "value": "The communication protocol used between client\nand server had a flaw that could be leveraged to execute a man in the middle attack." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-295", "description": "CWE-295 Improper Certificate Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-11T06:03:29.926Z", "orgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "shortName": "Axis" }, "references": [ { "url": "https://www.axis.com/dam/public/01/d9/24/cve-2025-30024pdf-en-US-485734.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "assignerShortName": "Axis", "cveId": "CVE-2025-30024", "datePublished": "2025-07-11T06:03:29.926Z", "dateReserved": "2025-03-14T05:27:55.732Z", "dateUpdated": "2025-07-11T16:28:42.727Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-30023 (GCVE-0-2025-30023)
Vulnerability from cvelistv5
Published
2025-07-11 06:02
Modified
2025-07-11 16:36
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Summary
The communication protocol used between client and server had a flaw that could lead to an authenticated user performing a remote code execution attack.
References
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Axis Communications AB | AXIS Camera Station Pro |
Version: <6.9 |
|||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-30023", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-07-11T16:30:26.166108Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-07-11T16:36:45.516Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AXIS Camera Station Pro", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c6.9" } ] }, { "defaultStatus": "unaffected", "product": "AXIS Camera Station", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c5.58" } ] }, { "defaultStatus": "unaffected", "product": "AXIS Device Manager", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c5.32" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noam Moshe of Claroty Team82" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The communication protocol used between client and server had a flaw that could lead to an authenticated user performing a remote code execution attack.\u003cbr\u003e" } ], "value": "The communication protocol used between client and server had a flaw that could lead to an authenticated user performing a remote code execution attack." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-11T06:02:00.620Z", "orgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "shortName": "Axis" }, "references": [ { "url": "https://www.axis.com/dam/public/9b/a5/72/cve-2025-30023pdf-en-US-485733.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "assignerShortName": "Axis", "cveId": "CVE-2025-30023", "datePublished": "2025-07-11T06:02:00.620Z", "dateReserved": "2025-03-14T05:27:55.732Z", "dateUpdated": "2025-07-11T16:36:45.516Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-31989 (GCVE-0-2021-31989)
Vulnerability from cvelistv5
Published
2021-08-25 18:29
Modified
2024-11-08 08:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-316 - Cleartext Storage of Sensitive Information in Memory
Summary
A user with permission to log on to the machine hosting the AXIS Device Manager client could under certain conditions extract a memory dump from the built-in Windows Task Manager application. The memory dump may potentially contain credentials of connected Axis devices.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Axis Communications AB | AXIS Device Manager |
Version: From Axis Device Manager 5.00.010 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:31.452Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.axis.com/files/tech_notes/CVE-2021-31989.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AXIS Device Manager", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "From Axis Device Manager 5.00.010" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eA user with permission to log on to the machine hosting the AXIS Device Manager client could under certain conditions extract a memory dump from the built-in Windows Task Manager application. The memory dump may potentially contain credentials of connected Axis devices.\u003c/p\u003e" } ], "value": "A user with permission to log on to the machine hosting the AXIS Device Manager client could under certain conditions extract a memory dump from the built-in Windows Task Manager application. The memory dump may potentially contain credentials of connected Axis devices." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-316", "description": "CWE-316: Cleartext Storage of Sensitive Information in Memory", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-08T08:21:08.424Z", "orgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "shortName": "Axis" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.axis.com/files/tech_notes/CVE-2021-31989.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "product-security@axis.com", "ID": "CVE-2021-31989", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Axis Device Manager", "version": { "version_data": [ { "version_value": "From Axis Device Manager 5.00.010" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A user with permission to log on to the machine hosting the AXIS Device Manager client could under certain conditions extract a memory dump from the built-in Windows Task Manager application. The memory dump may potentially contain credentials of connected Axis devices." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Plaintext storage of credentials in RAM memory" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.axis.com/files/tech_notes/CVE-2021-31989.pdf", "refsource": "MISC", "url": "https://www.axis.com/files/tech_notes/CVE-2021-31989.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "assignerShortName": "Axis", "cveId": "CVE-2021-31989", "datePublished": "2021-08-25T18:29:41", "dateReserved": "2021-04-30T00:00:00", "dateUpdated": "2024-11-08T08:21:08.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-30025 (GCVE-0-2025-30025)
Vulnerability from cvelistv5
Published
2025-07-11 06:04
Modified
2025-07-11 13:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Summary
The communication protocol used between the
server process and the service control had a flaw that could lead to a local privilege escalation.
References
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Axis Communications AB | AXIS Device Manager |
Version: <5.32 |
|||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-30025", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-07-11T13:22:32.432800Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-07-11T13:22:38.539Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AXIS Device Manager", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c5.32" } ] }, { "defaultStatus": "unaffected", "product": "AXIS Camera Station Pro", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c6.8" } ] }, { "defaultStatus": "unaffected", "product": "AXIS Camera Station", "vendor": "Axis Communications AB", "versions": [ { "status": "affected", "version": "\u003c6" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noam Moshe of Claroty Team82" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The communication protocol used between the\nserver process and the service control had a flaw that could lead to a local privilege escalation.\n\n\u003cbr\u003e" } ], "value": "The communication protocol used between the\nserver process and the service control had a flaw that could lead to a local privilege escalation." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 4.8, "baseSeverity": "MEDIUM", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "LOW", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "LOW", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:L/SI:L/SA:L", "version": "4.0", "vulnAvailabilityImpact": "LOW", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "LOW", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-11T06:04:40.972Z", "orgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "shortName": "Axis" }, "references": [ { "url": "https://www.axis.com/dam/public/40/0e/03/cve-2025-30025pdf-en-US-485736.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807", "assignerShortName": "Axis", "cveId": "CVE-2025-30025", "datePublished": "2025-07-11T06:04:40.972Z", "dateReserved": "2025-03-14T05:27:55.732Z", "dateUpdated": "2025-07-11T13:22:38.539Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }