CVE-2025-30025 (GCVE-0-2025-30025)
Vulnerability from cvelistv5
Published
2025-07-11 06:04
Modified
2025-07-11 13:22
CWE
  • CWE-502 - Deserialization of Untrusted Data
Summary
The communication protocol used between the server process and the service control had a flaw that could lead to a local privilege escalation.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30025",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-11T13:22:32.432800Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-11T13:22:38.539Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AXIS Device Manager",
          "vendor": "Axis Communications AB",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c5.32"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXIS Camera Station Pro",
          "vendor": "Axis Communications AB",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c6.8"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXIS Camera Station",
          "vendor": "Axis Communications AB",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe of Claroty Team82"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The communication protocol used between the\nserver process and the service control had a flaw that could lead to a local privilege escalation.\n\n\u003cbr\u003e"
            }
          ],
          "value": "The communication protocol used between the\nserver process and the service control had a flaw that could lead to a local privilege escalation."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-11T06:04:40.972Z",
        "orgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807",
        "shortName": "Axis"
      },
      "references": [
        {
          "url": "https://www.axis.com/dam/public/40/0e/03/cve-2025-30025pdf-en-US-485736.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2daf9a0-02c2-4b83-a01d-63b3b304b807",
    "assignerShortName": "Axis",
    "cveId": "CVE-2025-30025",
    "datePublished": "2025-07-11T06:04:40.972Z",
    "dateReserved": "2025-03-14T05:27:55.732Z",
    "dateUpdated": "2025-07-11T13:22:38.539Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-30025\",\"sourceIdentifier\":\"product-security@axis.com\",\"published\":\"2025-07-11T06:15:24.703\",\"lastModified\":\"2025-07-15T13:14:49.980\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The communication protocol used between the\\nserver process and the service control had a flaw that could lead to a local privilege escalation.\"},{\"lang\":\"es\",\"value\":\"El protocolo de comunicaci\u00f3n utilizado entre el proceso del servidor y el control del servicio ten\u00eda una falla que podr\u00eda conducir a una escalada de privilegios locales.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"product-security@axis.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"LOW\",\"subIntegrityImpact\":\"LOW\",\"subAvailabilityImpact\":\"LOW\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"product-security@axis.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-502\"}]}],\"references\":[{\"url\":\"https://www.axis.com/dam/public/40/0e/03/cve-2025-30025pdf-en-US-485736.pdf\",\"source\":\"product-security@axis.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-30025\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-11T13:22:32.432800Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-11T13:22:35.687Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Noam Moshe of Claroty Team82\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 4.8, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:L/SI:L/SA:L\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"LOW\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"LOW\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Axis Communications AB\", \"product\": \"AXIS Device Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003c5.32\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Axis Communications AB\", \"product\": \"AXIS Camera Station Pro\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003c6.8\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Axis Communications AB\", \"product\": \"AXIS Camera Station\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003c6\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.axis.com/dam/public/40/0e/03/cve-2025-30025pdf-en-US-485736.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The communication protocol used between the\\nserver process and the service control had a flaw that could lead to a local privilege escalation.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The communication protocol used between the\\nserver process and the service control had a flaw that could lead to a local privilege escalation.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-502\", \"description\": \"CWE-502 Deserialization of Untrusted Data\"}]}], \"providerMetadata\": {\"orgId\": \"f2daf9a0-02c2-4b83-a01d-63b3b304b807\", \"shortName\": \"Axis\", \"dateUpdated\": \"2025-07-11T06:04:40.972Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-30025\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-11T13:22:38.539Z\", \"dateReserved\": \"2025-03-14T05:27:55.732Z\", \"assignerOrgId\": \"f2daf9a0-02c2-4b83-a01d-63b3b304b807\", \"datePublished\": \"2025-07-11T06:04:40.972Z\", \"assignerShortName\": \"Axis\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…