Vulnerabilites related to NetIQ - Access Manager
CVE-2017-9276 (GCVE-0-2017-9276)
Vulnerability from cvelistv5
Published
2018-03-02 20:00
Modified
2024-09-17 03:48
CWE
Summary
Novell Access Manager iManager before 4.3.3 did not validate parameters so that cross site scripting content could be reflected back into the result page using the "a" parameter.
References
Impacted products
Vendor Product Version
NetIQ Access Manager Version: unspecified   < 4.3.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:02:44.180Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=7022359"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.3.3",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-11-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Novell Access Manager iManager before 4.3.3 did not validate parameters so that cross site scripting content could be reflected back into the result page using the \"a\" parameter."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:33",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=7022359"
        }
      ],
      "source": {
        "advisory": "7022359",
        "defect": [
          "1044115"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "XSS Vulnerability in iManager",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-11-20T00:00:00.000Z",
          "ID": "CVE-2017-9276",
          "STATE": "PUBLIC",
          "TITLE": "XSS Vulnerability in iManager"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "4.3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Novell Access Manager iManager before 4.3.3 did not validate parameters so that cross site scripting content could be reflected back into the result page using the \"a\" parameter."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=7022359",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=7022359"
            }
          ]
        },
        "source": {
          "advisory": "7022359",
          "defect": [
            "1044115"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-9276",
    "datePublished": "2018-03-02T20:00:00Z",
    "dateReserved": "2017-05-29T00:00:00",
    "dateUpdated": "2024-09-17T03:48:57.392Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14800 (GCVE-0-2017-14800)
Vulnerability from cvelistv5
Published
2018-03-01 19:00
Modified
2024-09-16 20:31
CWE
  • reflected cross site scripting attack
Summary
A reflected cross site scripting attack in the NetIQ Access Manager before 4.3.3 using the "typecontainerid" parameter of the policy editor could allowed code injection into pages of authenticated users.
References
Impacted products
Vendor Product Version
NetIQ Access Manager Version: 4.3   < 4.3.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:34:40.340Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=7022356"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.3.3",
              "status": "affected",
              "version": "4.3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-11-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A reflected cross site scripting attack in the NetIQ Access Manager before 4.3.3 using the \"typecontainerid\" parameter of the policy editor could allowed code injection into pages of authenticated users."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "reflected cross site scripting attack",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:51",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=7022356"
        }
      ],
      "source": {
        "advisory": "7022356",
        "discovery": "UNKNOWN"
      },
      "title": "Reflected xss on Access Manager iManager UI",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-11-20T00:00:00.000Z",
          "ID": "CVE-2017-14800",
          "STATE": "PUBLIC",
          "TITLE": "Reflected xss on Access Manager iManager UI"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "4.3",
                            "version_value": "4.3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A reflected cross site scripting attack in the NetIQ Access Manager before 4.3.3 using the \"typecontainerid\" parameter of the policy editor could allowed code injection into pages of authenticated users."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "reflected cross site scripting attack"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=7022356",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=7022356"
            }
          ]
        },
        "source": {
          "advisory": "7022356",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-14800",
    "datePublished": "2018-03-01T19:00:00Z",
    "dateReserved": "2017-09-27T00:00:00",
    "dateUpdated": "2024-09-16T20:31:45.697Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14799 (GCVE-0-2017-14799)
Vulnerability from cvelistv5
Published
2018-03-01 19:00
Modified
2024-09-16 17:23
CWE
  • cross site scripting attack in the login parameter handling due to incorrect quoting
Summary
A cross site scripting attack in handling the ESP login parameter handling in NetIQ Access Manager before 4.3.3 could be used to inject javascript code into the login page.
References
Impacted products
Vendor Product Version
NetIQ Access Manager Version: 4.3   < 4.3.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:34:40.366Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=7022358"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.3.3",
              "status": "affected",
              "version": "4.3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-11-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A cross site scripting attack in handling the ESP login parameter handling in NetIQ Access Manager before 4.3.3 could be used to inject javascript code into the login page."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cross site scripting attack in the login parameter handling due to incorrect quoting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:16:07",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=7022358"
        }
      ],
      "source": {
        "advisory": "7022358",
        "discovery": "EXTERNAL"
      },
      "title": "XSS Vulnerability with ESP URL",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-11-20T00:00:00.000Z",
          "ID": "CVE-2017-14799",
          "STATE": "PUBLIC",
          "TITLE": "XSS Vulnerability with ESP URL"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "4.3",
                            "version_value": "4.3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A cross site scripting attack in handling the ESP login parameter handling in NetIQ Access Manager before 4.3.3 could be used to inject javascript code into the login page."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cross site scripting attack in the login parameter handling due to incorrect quoting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=7022358",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=7022358"
            }
          ]
        },
        "source": {
          "advisory": "7022358",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-14799",
    "datePublished": "2018-03-01T19:00:00Z",
    "dateReserved": "2017-09-27T00:00:00",
    "dateUpdated": "2024-09-16T17:23:57.367Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14801 (GCVE-0-2017-14801)
Vulnerability from cvelistv5
Published
2018-03-02 20:00
Modified
2024-09-17 03:03
CWE
  • Reflected cross site scripting
  • CWE-79
Summary
Reflected XSS in the NetIQ Access Manager before 4.3.3 allowed attackers to reflect back xss into the called page using the url parameter.
References
Impacted products
Vendor Product Version
NetIQ Access Manager Version: 4.3   < 4.3.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:34:39.941Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=7022357"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.3.3",
              "status": "affected",
              "version": "4.3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-11-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Reflected XSS in the NetIQ Access Manager before 4.3.3 allowed attackers to reflect back xss into the called page using the url parameter."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Reflected cross site scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:26",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=7022357"
        }
      ],
      "source": {
        "advisory": "7022357",
        "discovery": "UNKNOWN"
      },
      "title": "Reflected xss in Admin Console REST interface",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-11-20T00:00:00.000Z",
          "ID": "CVE-2017-14801",
          "STATE": "PUBLIC",
          "TITLE": "Reflected xss in Admin Console REST interface"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "4.3",
                            "version_value": "4.3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Reflected XSS in the NetIQ Access Manager before 4.3.3 allowed attackers to reflect back xss into the called page using the url parameter."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Reflected cross site scripting"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=7022357",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=7022357"
            }
          ]
        },
        "source": {
          "advisory": "7022357",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-14801",
    "datePublished": "2018-03-02T20:00:00Z",
    "dateReserved": "2017-09-27T00:00:00",
    "dateUpdated": "2024-09-17T03:03:50.688Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7419 (GCVE-0-2017-7419)
Vulnerability from cvelistv5
Published
2018-03-02 20:00
Modified
2024-09-16 17:29
CWE
  • cross site scripting attack
  • CWE-79
Summary
A OAuth application in NetIQ Access Manager 4.3 before 4.3.2 and 4.2 before 4.2.4 allowed cross site scripting attacks due to unescaped "description" field that could be specified by the provider.
Impacted products
Vendor Product Version
NetIQ Access Manager Version: 4.3   < 4.3.2
Version: 4.2   < 4.2.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:04:11.275Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1031853"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=7019893"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.3.2",
              "status": "affected",
              "version": "4.3",
              "versionType": "custom"
            },
            {
              "lessThan": "4.2.4",
              "status": "affected",
              "version": "4.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-06-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A OAuth application in NetIQ Access Manager 4.3 before 4.3.2 and 4.2 before 4.2.4 allowed cross site scripting attacks due to unescaped \"description\" field that could be specified by the provider."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cross site scripting attack",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:40",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1031853"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=7019893"
        }
      ],
      "source": {
        "advisory": "7019893",
        "defect": [
          "1031853"
        ],
        "discovery": "INTERNAL"
      },
      "title": "NetIQ Access Manager OAuth Consent screen XSS attack",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-06-09T00:00:00.000Z",
          "ID": "CVE-2017-7419",
          "STATE": "PUBLIC",
          "TITLE": "NetIQ Access Manager OAuth Consent screen XSS attack"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "4.3",
                            "version_value": "4.3.2"
                          },
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "4.2",
                            "version_value": "4.2.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A OAuth application in NetIQ Access Manager 4.3 before 4.3.2 and 4.2 before 4.2.4 allowed cross site scripting attacks due to unescaped \"description\" field that could be specified by the provider."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cross site scripting attack"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.suse.com/show_bug.cgi?id=1031853",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.suse.com/show_bug.cgi?id=1031853"
            },
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=7019893",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=7019893"
            }
          ]
        },
        "source": {
          "advisory": "7019893",
          "defect": [
            "1031853"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-7419",
    "datePublished": "2018-03-02T20:00:00Z",
    "dateReserved": "2017-04-05T00:00:00",
    "dateUpdated": "2024-09-16T17:29:02.147Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-14802 (GCVE-0-2017-14802)
Vulnerability from cvelistv5
Published
2018-03-02 20:00
Modified
2024-09-17 02:41
CWE
  • redirect to untrusted sites
  • CWE-601
Summary
Novell Access Manager Admin Console and IDP servers before 4.3.3 have a URL that could be used by remote attackers to trigger unvalidated redirects to third party sites.
References
Impacted products
Vendor Product Version
NetIQ Access Manager Version: 4.3   < 4.3.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T19:34:39.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.novell.com/support/kb/doc.php?id=7022360"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Manager",
          "vendor": "NetIQ",
          "versions": [
            {
              "lessThan": "4.3.3",
              "status": "affected",
              "version": "4.3",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2017-11-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Novell Access Manager Admin Console and IDP servers before 4.3.3 have a URL that could be used by remote attackers to trigger unvalidated redirects to third party sites."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "redirect to untrusted sites",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-06T16:15:26",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.novell.com/support/kb/doc.php?id=7022360"
        }
      ],
      "source": {
        "advisory": "7022360",
        "discovery": "EXTERNAL"
      },
      "title": "Unvalidated Redirect in NetIQ Access Manager after upgrading to NAM 4.3 AC and IDP URLs",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "DATE_PUBLIC": "2017-11-20T00:00:00.000Z",
          "ID": "CVE-2017-14802",
          "STATE": "PUBLIC",
          "TITLE": "Unvalidated Redirect in NetIQ Access Manager after upgrading to NAM 4.3 AC and IDP URLs"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Manager",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "4.3",
                            "version_value": "4.3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NetIQ"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Novell Access Manager Admin Console and IDP servers before 4.3.3 have a URL that could be used by remote attackers to trigger unvalidated redirects to third party sites."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "redirect to untrusted sites"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-601"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.novell.com/support/kb/doc.php?id=7022360",
              "refsource": "CONFIRM",
              "url": "https://www.novell.com/support/kb/doc.php?id=7022360"
            }
          ]
        },
        "source": {
          "advisory": "7022360",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2017-14802",
    "datePublished": "2018-03-02T20:00:00Z",
    "dateReserved": "2017-09-27T00:00:00",
    "dateUpdated": "2024-09-17T02:41:52.181Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}