Vulnerabilites related to Autel - Autel MaxiCharger AC Wallbox Commercial
CVE-2025-5824 (GCVE-0-2025-5824)
Vulnerability from cvelistv5
Published
2025-06-25 17:59
Modified
2025-06-25 18:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-346 - Origin Validation Error
Summary
Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5824", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-25T18:21:18.194673Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:21:28.310Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:16:45.821Z", "datePublic": "2025-06-11T17:27:11.046Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353." } ], "metrics": [ { "cvssV3_0": { "baseScore": 5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-346", "description": "CWE-346: Origin Validation Error", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T17:59:54.446Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-343", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-343/" } ], "source": { "lang": "en", "value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)" }, "title": "Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5824", "datePublished": "2025-06-25T17:59:54.446Z", "dateReserved": "2025-06-06T19:16:45.792Z", "dateUpdated": "2025-06-25T18:21:28.310Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5828 (GCVE-0-2025-5828)
Vulnerability from cvelistv5
Published
2025-06-25 18:00
Modified
2025-06-26 13:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5828", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:18:15.946259Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:18:21.495Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:17:04.884Z", "datePublic": "2025-06-11T17:27:31.420Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328." } ], "metrics": [ { "cvssV3_0": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:00:44.220Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-347", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-347/" } ], "source": { "lang": "en", "value": "Synacktiv" }, "title": "Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5828", "datePublished": "2025-06-25T18:00:44.220Z", "dateReserved": "2025-06-06T19:17:04.853Z", "dateUpdated": "2025-06-26T13:18:21.495Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-6678 (GCVE-0-2025-6678)
Vulnerability from cvelistv5
Published
2025-06-25 18:02
Modified
2025-06-25 19:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-6678", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-25T19:19:55.574968Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-25T19:20:07.414Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-25T18:02:04.013Z", "datePublic": "2025-06-11T17:27:06.576Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352." } ], "metrics": [ { "cvssV3_0": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:02:09.371Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-342", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-342/" } ], "source": { "lang": "en", "value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)" }, "title": "Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-6678", "datePublished": "2025-06-25T18:02:09.371Z", "dateReserved": "2025-06-25T18:02:03.974Z", "dateUpdated": "2025-06-25T19:20:07.414Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5823 (GCVE-0-2025-5823)
Vulnerability from cvelistv5
Published
2025-06-25 18:01
Modified
2025-06-26 13:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-749 - Exposed Dangerous Method or Function
Summary
Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is required to exploit this vulnerability.
The specific flaw exists within the implementation of the Autel Technician API. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26351.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5823", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:16:57.354561Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:17:04.941Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:16:38.454Z", "datePublic": "2025-06-11T17:27:01.850Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the implementation of the Autel Technician API. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26351." } ], "metrics": [ { "cvssV3_0": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-749", "description": "CWE-749: Exposed Dangerous Method or Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:01:07.948Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-341", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-341/" } ], "source": { "lang": "en", "value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)" }, "title": "Autel MaxiCharger AC Wallbox Commercial Serial Number Exposed Dangerous Method Information Disclosure Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5823", "datePublished": "2025-06-25T18:01:07.948Z", "dateReserved": "2025-06-06T19:16:38.423Z", "dateUpdated": "2025-06-26T13:17:04.941Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5829 (GCVE-0-2025-5829)
Vulnerability from cvelistv5
Published
2025-06-25 18:01
Modified
2025-06-26 13:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
Autel MaxiCharger AC Wallbox Commercial autocharge Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of JSON messages. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26330.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5829", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:16:43.440338Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:16:48.689Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:17:08.065Z", "datePublic": "2025-06-11T17:27:35.696Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial autocharge Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of JSON messages. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26330." } ], "metrics": [ { "cvssV3_0": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:01:13.334Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-348", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-348/" } ], "source": { "lang": "en", "value": "Tobias Scharnowski, Felix Buchmann, and Kristian Covic of fuzzware.io" }, "title": "Autel MaxiCharger AC Wallbox Commercial autocharge Stack-based Buffer Overflow Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5829", "datePublished": "2025-06-25T18:01:13.334Z", "dateReserved": "2025-06-06T19:17:08.033Z", "dateUpdated": "2025-06-26T13:16:48.689Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5822 (GCVE-0-2025-5822)
Vulnerability from cvelistv5
Published
2025-06-25 18:00
Modified
2025-06-26 13:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-863 - Incorrect Authorization
Summary
Autel MaxiCharger AC Wallbox Commercial Technician API Incorrect Authorization Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain a low-privileged authorization token in order to exploit this vulnerability.
The specific flaw exists within the implementation of the Autel Technician API. The issue results from incorrect authorization. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. Was ZDI-CAN-26325.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5822", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:17:58.707658Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:18:05.218Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:16:34.709Z", "datePublic": "2025-06-11T17:26:56.849Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial Technician API Incorrect Authorization Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain a low-privileged authorization token in order to exploit this vulnerability.\n\nThe specific flaw exists within the implementation of the Autel Technician API. The issue results from incorrect authorization. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. Was ZDI-CAN-26325." } ], "metrics": [ { "cvssV3_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-863", "description": "CWE-863: Incorrect Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:00:49.179Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-340", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-340/" } ], "source": { "lang": "en", "value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)" }, "title": "Autel MaxiCharger AC Wallbox Commercial Technician API Incorrect Authorization Privilege Escalation Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5822", "datePublished": "2025-06-25T18:00:49.179Z", "dateReserved": "2025-06-06T19:16:34.664Z", "dateUpdated": "2025-06-26T13:18:05.218Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5825 (GCVE-0-2025-5825)
Vulnerability from cvelistv5
Published
2025-06-25 18:02
Modified
2025-06-25 18:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1328 - Security Version Number Mutable to Older Versions
Summary
Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5825", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-25T18:17:50.082273Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:18:01.073Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:16:51.093Z", "datePublic": "2025-06-11T17:27:15.633Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354." } ], "metrics": [ { "cvssV3_0": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1328", "description": "CWE-1328: Security Version Number Mutable to Older Versions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:02:18.293Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-344", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-344/" } ], "source": { "lang": "en", "value": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)" }, "title": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5825", "datePublished": "2025-06-25T18:02:18.293Z", "dateReserved": "2025-06-06T19:16:51.065Z", "dateUpdated": "2025-06-25T18:18:01.073Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5830 (GCVE-0-2025-5830)
Vulnerability from cvelistv5
Published
2025-06-25 18:01
Modified
2025-06-26 13:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-122 - Heap-based Buffer Overflow
Summary
Autel MaxiCharger AC Wallbox Commercial DLB_SlaveRegister Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of DLB_SlaveRegister messages. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26327.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5830", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:16:25.684852Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:16:32.252Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:17:13.272Z", "datePublic": "2025-06-11T17:27:46.341Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial DLB_SlaveRegister Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DLB_SlaveRegister messages. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26327." } ], "metrics": [ { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122: Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:01:20.050Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-349", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-349/" } ], "source": { "lang": "en", "value": "PHP Hooligans" }, "title": "Autel MaxiCharger AC Wallbox Commercial DLB_SlaveRegister Heap-based Buffer Overflow Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5830", "datePublished": "2025-06-25T18:01:20.050Z", "dateReserved": "2025-06-06T19:17:13.239Z", "dateUpdated": "2025-06-26T13:16:32.252Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5827 (GCVE-0-2025-5827)
Vulnerability from cvelistv5
Published
2025-06-25 18:00
Modified
2025-06-26 13:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the ble_process_esp32_msg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26369.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5827", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:17:14.944200Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:17:21.331Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:17:00.448Z", "datePublic": "2025-06-11T17:27:25.163Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ble_process_esp32_msg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26369." } ], "metrics": [ { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:00:54.449Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-346", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-346/" } ], "source": { "lang": "en", "value": "Quarkslab" }, "title": "Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Stack-based Buffer Overflow Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5827", "datePublished": "2025-06-25T18:00:54.449Z", "dateReserved": "2025-06-06T19:17:00.418Z", "dateUpdated": "2025-06-26T13:17:21.331Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5826 (GCVE-0-2025-5826)
Vulnerability from cvelistv5
Published
2025-06-25 18:00
Modified
2025-06-26 13:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-115 - Misinterpretation of Input
Summary
Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Misinterpretation of Input Vulnerability. This vulnerability allows network-adjacent attackers to inject arbitrary AT commands on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the ble_process_esp32_msg function. The issue results from misinterpretation of input data. An attacker can leverage this vulnerability to execute AT commands in the context of the device. Was ZDI-CAN-26368.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5826", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:18:29.924076Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:18:35.182Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:16:55.452Z", "datePublic": "2025-06-11T17:27:21.049Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Misinterpretation of Input Vulnerability. This vulnerability allows network-adjacent attackers to inject arbitrary AT commands on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ble_process_esp32_msg function. The issue results from misinterpretation of input data. An attacker can leverage this vulnerability to execute AT commands in the context of the device. Was ZDI-CAN-26368." } ], "metrics": [ { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-115", "description": "CWE-115: Misinterpretation of Input", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:00:38.520Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-345", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-345/" } ], "source": { "lang": "en", "value": "Quarkslab" }, "title": "Autel MaxiCharger AC Wallbox Commercial ble_process_esp32_msg Misinterpretation of Input Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5826", "datePublished": "2025-06-25T18:00:38.520Z", "dateReserved": "2025-06-06T19:16:55.415Z", "dateUpdated": "2025-06-26T13:18:35.182Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }