Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial |
Version: 1.36.00 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5828", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-26T13:18:15.946259Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-26T13:18:21.495Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Autel MaxiCharger AC Wallbox Commercial", "vendor": "Autel", "versions": [ { "status": "affected", "version": "1.36.00" } ] } ], "dateAssigned": "2025-06-06T19:17:04.884Z", "datePublic": "2025-06-11T17:27:31.420Z", "descriptions": [ { "lang": "en", "value": "Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328." } ], "metrics": [ { "cvssV3_0": { "baseScore": 6.8, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-25T18:00:44.220Z", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "name": "ZDI-25-347", "tags": [ "x_research-advisory" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-347/" } ], "source": { "lang": "en", "value": "Synacktiv" }, "title": "Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2025-5828", "datePublished": "2025-06-25T18:00:44.220Z", "dateReserved": "2025-06-06T19:17:04.853Z", "dateUpdated": "2025-06-26T13:18:21.495Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-5828\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2025-06-25T18:15:23.683\",\"lastModified\":\"2025-06-26T18:57:43.670\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo por desbordamiento de b\u00fafer en Autel MaxiCharger AC Wallbox Commercial wLength. Esta vulnerabilidad permite a atacantes con presencia f\u00edsica ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de cargadores de veh\u00edculos el\u00e9ctricos Autel MaxiCharger AC Wallbox Commercial. No se requiere autenticaci\u00f3n para explotar esta vulnerabilidad. La falla espec\u00edfica se encuentra en el manejo de paquetes de trama USB. El problema se debe a la falta de una validaci\u00f3n adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un b\u00fafer de longitud fija. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del dispositivo. Era ZDI-CAN-26328.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-25-347/\",\"source\":\"zdi-disclosures@trendmicro.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5828\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-26T13:18:15.946259Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-26T13:18:18.906Z\"}}], \"cna\": {\"title\": \"Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Synacktiv\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\"}}], \"affected\": [{\"vendor\": \"Autel\", \"product\": \"Autel MaxiCharger AC Wallbox Commercial\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.36.00\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2025-06-11T17:27:31.420Z\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-25-347/\", \"name\": \"ZDI-25-347\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2025-06-06T19:17:04.884Z\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2025-06-25T18:00:44.220Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-5828\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-26T13:18:21.495Z\", \"dateReserved\": \"2025-06-06T19:17:04.853Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2025-06-25T18:00:44.220Z\", \"assignerShortName\": \"zdi\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…