Vulnerabilites related to Philips - DoseWise Portal
CVE-2017-9656 (GCVE-0-2017-9656)
Vulnerability from cvelistv5
Published
2018-04-24 15:00
Modified
2024-09-17 00:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of hard-coded credentials
Summary
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Philips | DoseWise Portal |
Version: 1.1.7.333 Version: 2.1.1.3069 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T17:18:01.463Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "100471", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/100471" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.philips.com/productsecurity" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DoseWise Portal", "vendor": "Philips", "versions": [ { "status": "affected", "version": "1.1.7.333" }, { "status": "affected", "version": "2.1.1.3069" } ] } ], "datePublic": "2017-08-17T00:00:00", "descriptions": [ { "lang": "en", "value": "The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "Use of hard-coded credentials CWE-798", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-04-25T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "name": "100471", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/100471" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.philips.com/productsecurity" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2017-08-17T00:00:00", "ID": "CVE-2017-9656", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DoseWise Portal", "version": { "version_data": [ { "version_value": "1.1.7.333" }, { "version_value": "2.1.1.3069" } ] } } ] }, "vendor_name": "Philips" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Use of hard-coded credentials CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "100471", "refsource": "BID", "url": "http://www.securityfocus.com/bid/100471" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01" }, { "name": "http://www.philips.com/productsecurity", "refsource": "CONFIRM", "url": "http://www.philips.com/productsecurity" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2017-9656", "datePublished": "2018-04-24T15:00:00Z", "dateReserved": "2017-06-14T00:00:00", "dateUpdated": "2024-09-17T00:06:52.060Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2017-9654 (GCVE-0-2017-9654)
Vulnerability from cvelistv5
Published
2018-04-24 15:00
Modified
2024-09-17 03:43
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-312 - Cleartext storage of sensitive information
Summary
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Philips | DoseWise Portal |
Version: 1.1.7.333 Version: 2.1.1.3069 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T17:18:00.345Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "100471", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/100471" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.philips.com/productsecurity" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "DoseWise Portal", "vendor": "Philips", "versions": [ { "status": "affected", "version": "1.1.7.333" }, { "status": "affected", "version": "2.1.1.3069" } ] } ], "datePublic": "2017-08-17T00:00:00", "descriptions": [ { "lang": "en", "value": "The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-312", "description": "Cleartext storage of sensitive information CWE-312", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-04-25T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "name": "100471", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/100471" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.philips.com/productsecurity" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2017-08-17T00:00:00", "ID": "CVE-2017-9654", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "DoseWise Portal", "version": { "version_data": [ { "version_value": "1.1.7.333" }, { "version_value": "2.1.1.3069" } ] } } ] }, "vendor_name": "Philips" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cleartext storage of sensitive information CWE-312" } ] } ] }, "references": { "reference_data": [ { "name": "100471", "refsource": "BID", "url": "http://www.securityfocus.com/bid/100471" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01" }, { "name": "http://www.philips.com/productsecurity", "refsource": "CONFIRM", "url": "http://www.philips.com/productsecurity" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2017-9654", "datePublished": "2018-04-24T15:00:00Z", "dateReserved": "2017-06-14T00:00:00", "dateUpdated": "2024-09-17T03:43:28.188Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }