Vulnerabilites related to Siemens - Energy Services
CVE-2025-40585 (GCVE-0-2025-40585)
Vulnerability from cvelistv5
Published
2025-06-10 15:17
Modified
2025-06-10 17:10
Severity ?
9.9 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L
9.5 (Critical) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:H/SA:L
9.5 (Critical) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:H/SA:L
VLAI Severity ?
EPSS score ?
CWE
- CWE-276 - Incorrect Default Permissions
Summary
A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | Energy Services |
Version: 0 < * |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-40585", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-10T17:10:44.561380Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-10T17:10:49.154Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Energy Services", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.9, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:L", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 9.5, "baseSeverity": "CRITICAL", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:H/SA:L", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-276", "description": "CWE-276: Incorrect Default Permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-10T15:17:35.035Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-345750.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2025-40585", "datePublished": "2025-06-10T15:17:35.035Z", "dateReserved": "2025-04-16T08:20:17.033Z", "dateUpdated": "2025-06-10T17:10:49.154Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }