CVE-2018-25090 (GCVE-0-2018-25090)
Vulnerability from cvelistv5
Published
2024-03-13 08:32
Modified
2024-08-05 15:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required. This leads to a limited impact of confidentiality and integrity but no impact of availability.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | WAGO | Controller BACnet/IP |
Version: 0 ≤ FW13 |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T12:33:48.504Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-039/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2018-25090", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-05T15:21:55.909544Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-05T15:22:05.933Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Controller BACnet/IP", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Controller BACnet MS/TP", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Ethernet Controller 3rd Generation", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Ethernet Controller 3rd Generation", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Fieldbus Coupler Ethernet 3rd Generation", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u0026nbsp;This leads to a limited impact of confidentiality and integrity but no impact of availability." } ], "value": "An unauthenticated remote attacker can use an XSS attack due to improper neutralization of input during web page generation. User interaction is required.\u00a0This leads to a limited impact of confidentiality and integrity but no impact of availability." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-13T08:32:17.180Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-039/" } ], "source": { "advisory": "VDE-2023-039", "defect": [ "CERT@VDE#64546" ], "discovery": "EXTERNAL" }, "title": "Wago: Improper Neutralization of Input During Web Page Generation in multiple devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2018-25090", "datePublished": "2024-03-13T08:32:17.180Z", "dateReserved": "2023-09-14T13:00:21.075Z", "dateUpdated": "2024-08-05T15:22:05.933Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2015-10123 (GCVE-0-2015-10123)
Vulnerability from cvelistv5
Published
2024-03-13 08:31
Modified
2024-10-23 09:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | WAGO | Controller BACnet/IP |
Version: 0 < |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T08:58:26.532Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-039/" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:wago:750-352_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-352_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-831_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-831_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-829_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-829_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-852_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-852_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-880_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-880_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-881_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-881_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-882_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-882_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-885_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-885_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-889_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-889_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "cpes": [ "cpe:2.3:o:wago:750-884_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "750-884_firmware", "vendor": "wago", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2015-10123", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-06T18:34:04.204030Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-06T19:37:09.871Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Controller BACnet/IP", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Controller BACnet MS/TP", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Ethernet Controller 3rd Generation", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Ethernet Controller 3rd Generation", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Fieldbus Coupler Ethernet 3rd Generation", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW13", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device.\u003cbr\u003e" } ], "value": "An unautheticated remote attacker could send specifically crafted packets to a affected device. If an authenticated user then views that data in a specific page of the web-based management a buffer overflow will be triggered to gain full access of the device." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-23T09:40:12.408Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-039/" } ], "source": { "advisory": "VDE-2023-039", "defect": [ "CERT@VDE#64546" ], "discovery": "EXTERNAL" }, "title": "Wago: Buffer Copy without Checking Size of Input in wbm of multiple products", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2015-10123", "datePublished": "2024-03-13T08:31:55.341Z", "dateReserved": "2023-09-14T13:00:03.904Z", "dateUpdated": "2024-10-23T09:40:12.408Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }