Vulnerabilites related to Siemens - JT Utilities
CVE-2021-44445 (GCVE-0-2021-44445)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
  • CWE-122 - Heap-based Buffer Overflow
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15054)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.917Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15054)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:05",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44445",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15054)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122: Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44445",
    "datePublished": "2021-12-14T12:07:05",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.917Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44450 (GCVE-0-2021-44450)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V12.8.1.1), JTTK (All versions < V10.8.1.1). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15055, ZDI-CAN-14915, ZDI-CAN-14865)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V12.8.1.1
Create a notification for this product.
   Siemens JTTK Version: All versions < V10.8.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V12.8.1.1"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V10.8.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V12.8.1.1), JTTK (All versions \u003c V10.8.1.1). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15055, ZDI-CAN-14915, ZDI-CAN-14865)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:08",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44450",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V12.8.1.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V10.8.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V12.8.1.1), JTTK (All versions \u003c V10.8.1.1). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15055, ZDI-CAN-14915, ZDI-CAN-14865)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44450",
    "datePublished": "2021-12-14T12:07:08",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44438 (GCVE-0-2021-44438)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14907)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.464Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14907)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:59",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44438",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14907)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44438",
    "datePublished": "2021-12-14T12:06:59",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.464Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44435 (GCVE-0-2021-44435)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14903)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14903)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:56",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44435",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14903)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44435",
    "datePublished": "2021-12-14T12:06:56",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.488Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44447 (GCVE-0-2021-44447)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.0.3.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.0.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.806Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.3.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.0.3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.3.0), JTTK (All versions \u003c V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:06",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44447",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.0.3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.3.0), JTTK (All versions \u003c V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-416: Use After Free"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44447",
    "datePublished": "2021-12-14T12:07:06",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.806Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44014 (GCVE-0-2021-44014)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:10
CWE
Summary
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15057, ZDI-CAN-19081)
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:10:17.199Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2023"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.1.1.0), JT Utilities (All versions \u003c V13.1.1.0), Solid Edge (All versions \u003c V2023). The Jt1001.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15057, ZDI-CAN-19081)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-10T11:39:18.959Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44014",
    "datePublished": "2021-12-14T12:06:50",
    "dateReserved": "2021-11-18T00:00:00",
    "dateUpdated": "2024-08-04T04:10:17.199Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-47935 (GCVE-0-2022-47935)
Vulnerability from cvelistv5
Published
2023-01-10 11:39
Modified
2025-04-08 20:04
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a memory corruption vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19078)
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:02:36.565Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-47935",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T20:03:09.102680Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T20:04:25.738Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2023"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.1.1.0), JT Utilities (All versions \u003c V13.1.1.0), Solid Edge (All versions \u003c V2023). The Jt1001.dll contains a memory corruption vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19078)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-10T11:39:47.238Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-47935",
    "datePublished": "2023-01-10T11:39:47.238Z",
    "dateReserved": "2022-12-23T11:05:07.688Z",
    "dateUpdated": "2025-04-08T20:04:25.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44442 (GCVE-0-2021-44442)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
  • CWE-122 - Heap-based Buffer Overflow
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14995)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14995)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44442",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14995)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122: Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44442",
    "datePublished": "2021-12-14T12:07:02",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.465Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44448 (GCVE-0-2021-44448)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14843, ZDI-CAN-15051)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.0.3.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.0.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.918Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.3.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.0.3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.3.0), JTTK (All versions \u003c V11.0.3.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14843, ZDI-CAN-15051)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:07",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44448",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.0.3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.3.0), JTTK (All versions \u003c V11.0.3.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14843, ZDI-CAN-15051)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44448",
    "datePublished": "2021-12-14T12:07:07",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.918Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44437 (GCVE-0-2021-44437)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14906)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.594Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14906)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:58",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44437",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14906)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44437",
    "datePublished": "2021-12-14T12:06:58",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.594Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44433 (GCVE-0-2021-44433)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.452Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416: Use After Free",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:55",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44433",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-416: Use After Free"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44433",
    "datePublished": "2021-12-14T12:06:55",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.452Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44440 (GCVE-0-2021-44440)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to memory corruption condition while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14912)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.432Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to memory corruption condition while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14912)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44440",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to memory corruption condition while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14912)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44440",
    "datePublished": "2021-12-14T12:07:00",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.432Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-47936 (GCVE-0-2022-47936)
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2025-03-20 20:07
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:02:36.549Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-47936",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T20:07:21.772715Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T20:07:30.206Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.2.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V35.0.170"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V35.1.150"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.2.3.0), JT Utilities (All versions \u003c V13.2.3.0), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:56.841Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-47936",
    "datePublished": "2023-02-14T10:36:21.369Z",
    "dateReserved": "2022-12-23T11:29:16.433Z",
    "dateUpdated": "2025-03-20T20:07:30.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33714 (GCVE-0-2021-33714)
Vulnerability from cvelistv5
Published
2021-07-13 11:03
Modified
2024-08-03 23:58
Severity ?
CWE
  • CWE-476 - NULL Pointer Dereference
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a missing check for the validity of an iterator leads to NULL pointer deference condition, causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.0.2.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:22.579Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.2.0). When parsing specially crafted JT files, a missing check for the validity of an iterator leads to NULL pointer deference condition, causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-13T11:03:04",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-33714",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.2.0). When parsing specially crafted JT files, a missing check for the validity of an iterator leads to NULL pointer deference condition, causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-476: NULL Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-33714",
    "datePublished": "2021-07-13T11:03:04",
    "dateReserved": "2021-05-28T00:00:00",
    "dateUpdated": "2024-08-03T23:58:22.579Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44434 (GCVE-0-2021-44434)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14902, ZDI-CAN-14866)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.505Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14902, ZDI-CAN-14866)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:56",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44434",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14902, ZDI-CAN-14866)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44434",
    "datePublished": "2021-12-14T12:06:56",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.505Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44441 (GCVE-0-2021-44441)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14913)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.418Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14913)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44441",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14913)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44441",
    "datePublished": "2021-12-14T12:07:01",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.418Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-29053 (GCVE-0-2023-29053)
Vulnerability from cvelistv5
Published
2023-04-11 09:03
Modified
2025-02-26 21:06
CWE
Summary
A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.3.2.0
Create a notification for this product.
   Siemens JT Utilities Version: All versions < V13.3.0.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:00:14.606Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-642810.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-29053",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-26T21:06:30.675103Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-125",
                "description": "CWE-125 Out-of-bounds Read",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-26T21:06:46.463Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.3.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.3.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.3.2.0), JT Utilities (All versions \u003c V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:03:07.730Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-642810.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-29053",
    "datePublished": "2023-04-11T09:03:07.730Z",
    "dateReserved": "2023-03-30T12:04:26.538Z",
    "dateUpdated": "2025-02-26T21:06:46.463Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44432 (GCVE-0-2021-44432)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14845)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:15.103Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14845)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:54",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44432",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14845)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44432",
    "datePublished": "2021-12-14T12:06:54",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:15.103Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44443 (GCVE-0-2021-44443)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15039)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.953Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15039)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:03",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44443",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15039)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44443",
    "datePublished": "2021-12-14T12:07:03",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44446 (GCVE-0-2021-44446)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14828, ZDI-CAN-14898)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.0.3.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.0.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.498Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.3.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.0.3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.3.0), JTTK (All versions \u003c V11.0.3.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14828, ZDI-CAN-14898)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:05",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44446",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.0.3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.3.0), JTTK (All versions \u003c V11.0.3.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14828, ZDI-CAN-14898)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44446",
    "datePublished": "2021-12-14T12:07:05",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.498Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44430 (GCVE-0-2021-44430)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.425Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:53",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44430",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14829)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44430",
    "datePublished": "2021-12-14T12:06:53",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.425Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44449 (GCVE-0-2021-44449)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V12.8.1.1), JTTK (All versions < V10.8.1.1). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14830)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V12.8.1.1
Create a notification for this product.
   Siemens JTTK Version: All versions < V10.8.1.1
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.834Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V12.8.1.1"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V10.8.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V12.8.1.1), JTTK (All versions \u003c V10.8.1.1). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14830)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:07:08",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44449",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V12.8.1.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V10.8.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V12.8.1.1), JTTK (All versions \u003c V10.8.1.1). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14830)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44449",
    "datePublished": "2021-12-14T12:07:08",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44439 (GCVE-0-2021-44439)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14908)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.782Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14908)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:59",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44439",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14908)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44439",
    "datePublished": "2021-12-14T12:06:59",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.782Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44431 (GCVE-0-2021-44431)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14841)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.853Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14841)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:53",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44431",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14841)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44431",
    "datePublished": "2021-12-14T12:06:53",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.853Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44444 (GCVE-0-2021-44444)
Vulnerability from cvelistv5
Published
2021-12-14 12:07
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15052)
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.449Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/167317/Microsoft-Office-MSDT-Follina-Proof-Of-Concept.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15052)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-31T18:06:21",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/167317/Microsoft-Office-MSDT-Follina-Proof-Of-Concept.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44444",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15052)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            },
            {
              "name": "http://packetstormsecurity.com/files/167317/Microsoft-Office-MSDT-Follina-Proof-Of-Concept.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/167317/Microsoft-Office-MSDT-Follina-Proof-Of-Concept.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44444",
    "datePublished": "2021-12-14T12:07:04",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.449Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33713 (GCVE-0-2021-33713)
Vulnerability from cvelistv5
Published
2021-07-13 11:03
Modified
2024-08-03 23:58
Severity ?
CWE
  • CWE-688 - Function Call With Incorrect Variable or Reference as Argument
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.0.2.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:22.818Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-688",
              "description": "CWE-688: Function Call With Incorrect Variable or Reference as Argument",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-13T11:03:03",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-33713",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-688: Function Call With Incorrect Variable or Reference as Argument"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-33713",
    "datePublished": "2021-07-13T11:03:03",
    "dateReserved": "2021-05-28T00:00:00",
    "dateUpdated": "2024-08-03T23:58:22.818Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33715 (GCVE-0-2021-33715)
Vulnerability from cvelistv5
Published
2021-07-13 11:03
Modified
2024-08-03 23:58
Severity ?
CWE
  • CWE-476 - NULL Pointer Dereference
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a race condition could cause an object to be released before being operated on, leading to NULL pointer deference condition and causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.0.2.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:22.582Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.0.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.2.0). When parsing specially crafted JT files, a race condition could cause an object to be released before being operated on, leading to NULL pointer deference condition and causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-13T11:03:05",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-33715",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.0.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.0.2.0). When parsing specially crafted JT files, a race condition could cause an object to be released before being operated on, leading to NULL pointer deference condition and causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-476: NULL Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-33715",
    "datePublished": "2021-07-13T11:03:05",
    "dateReserved": "2021-05-28T00:00:00",
    "dateUpdated": "2024-08-03T23:58:22.582Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-47977 (GCVE-0-2022-47977)
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2025-03-20 16:49
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0). The affected application contains a memory corruption vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.2.3.0
Create a notification for this product.
   Siemens JT Utilities Version: All versions < V13.2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:02:36.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-47977",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T16:49:04.865039Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T16:49:09.008Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.2.3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.2.3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.2.3.0), JT Utilities (All versions \u003c V13.2.3.0). The affected application contains a memory corruption vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:57.845Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-47977",
    "datePublished": "2023-02-14T10:36:22.513Z",
    "dateReserved": "2022-12-28T09:38:47.265Z",
    "dateUpdated": "2025-03-20T16:49:09.008Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44436 (GCVE-0-2021-44436)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:25
Severity ?
CWE
Summary
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14905)
References
Impacted products
Vendor Product Version
Siemens JT Utilities Version: All versions < V13.1.1.0
Create a notification for this product.
   Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V11.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14905)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:57",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44436",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "JT Utilities",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13.1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "JTTK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V11.1.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in JT Utilities (All versions \u003c V13.1.1.0), JTTK (All versions \u003c V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14905)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44436",
    "datePublished": "2021-12-14T12:06:57",
    "dateReserved": "2021-11-30T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-30796 (GCVE-0-2023-30796)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-11 22:14
CWE
Summary
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:37:15.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-30796",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-11T22:14:13.209203Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-11T22:14:44.670Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.4), JT Utilities (All versions \u003c V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:21.061Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-30796",
    "datePublished": "2023-08-08T09:20:21.061Z",
    "dateReserved": "2023-04-18T09:19:57.943Z",
    "dateUpdated": "2024-10-11T22:14:44.670Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-30795 (GCVE-0-2023-30795)
Vulnerability from cvelistv5
Published
2023-08-08 09:20
Modified
2024-10-11 22:16
CWE
Summary
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:37:15.439Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-30795",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-11T22:16:06.900938Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-11T22:16:31.109Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.253"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.243"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V35.0.177"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V35.1.073"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.4), JT Utilities (All versions \u003c V13.4), Parasolid V34.0 (All versions \u003c V34.0.253), Parasolid V34.1 (All versions \u003c V34.1.243), Parasolid V35.0 (All versions \u003c V35.0.177), Parasolid V35.1 (All versions \u003c V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:19.964Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-30795",
    "datePublished": "2023-08-08T09:20:19.964Z",
    "dateReserved": "2023-04-18T09:19:57.943Z",
    "dateUpdated": "2024-10-11T22:16:31.109Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44002 (GCVE-0-2021-44002)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:10
CWE
Summary
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15058, ZDI-CAN-19076, ZDI-CAN-19077)
Impacted products
Vendor Product Version
Siemens JT Open Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:10:17.089Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "JT Open",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "JT Utilities",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13.1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2023"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.1.1.0), JT Utilities (All versions \u003c V13.1.1.0), Solid Edge (All versions \u003c V2023). The Jt1001.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15058, ZDI-CAN-19076, ZDI-CAN-19077)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-10T11:39:17.904Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44002",
    "datePublished": "2021-12-14T12:06:41",
    "dateReserved": "2021-11-18T00:00:00",
    "dateUpdated": "2024-08-04T04:10:17.089Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}