Vulnerabilites related to Siemens - SIPLUS NET SCALANCE X202-2P IRT
CVE-2023-29054 (GCVE-0-2023-29054)
Vulnerability from cvelistv5
Published
2023-04-11 09:03
Modified
2025-02-07 16:49
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-326 - Inadequate Encryption Strength
Summary
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.
This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data
passed over the connection between legitimate clients and the affected device.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.2 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:00:14.631Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-29054", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-07T16:49:12.465183Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-07T16:49:26.184Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-326", "description": "CWE-326: Inadequate Encryption Strength", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:03:08.813Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-29054", "datePublished": "2023-04-11T09:03:08.813Z", "dateReserved": "2023-03-30T12:04:26.539Z", "dateUpdated": "2025-02-07T16:49:26.184Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2022-40631 (GCVE-0-2022-40631)
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2024-08-03 12:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SCALANCE X200-4P IRT |
Version: All versions < V5.5.0 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:21:46.592Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.5" } ] }, { "product": "SIPLUS NET SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-11T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-40631", "datePublished": "2022-10-11T00:00:00", "dateReserved": "2022-09-13T00:00:00", "dateUpdated": "2024-08-03T12:21:46.592Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }