Vulnerabilites related to Siemens - Simcenter Femap V2022.1
CVE-2022-41851 (GCVE-0-2022-41851)
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2025-05-20 14:13
CWE
  • CWE-824 - Access of Uninitialized Pointer
Summary
A vulnerability has been identified in JTTK (All versions < V11.1.1.0), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973)
Impacted products
Vendor Product Version
Siemens JTTK Version: All versions < V11.1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:56:38.099Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-611756.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-41851",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-20T14:13:03.902435Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-20T14:13:22.359Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "JTTK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V11.1.1.0"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in JTTK (All versions \u003c V11.1.1.0), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824: Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-11T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-611756.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-41851",
    "datePublished": "2022-10-11T00:00:00.000Z",
    "dateReserved": "2022-09-30T00:00:00.000Z",
    "dateUpdated": "2025-05-20T14:13:22.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39137 (GCVE-0-2022-39137)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.392Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:54",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39137",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17276)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39137",
    "datePublished": "2022-09-13T09:40:54",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.392Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39156 (GCVE-0-2022-39156)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.600Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:10",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39156",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39156",
    "datePublished": "2022-09-13T09:41:10",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.600Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39139 (GCVE-0-2022-39139)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17289)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.550Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17289)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:55",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39139",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17289)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39139",
    "datePublished": "2022-09-13T09:40:56",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.550Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39138 (GCVE-0-2022-39138)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17284)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.638Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17284)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:55",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39138",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17284)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39138",
    "datePublished": "2022-09-13T09:40:55",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.638Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39141 (GCVE-0-2022-39141)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.617Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:57",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39141",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39141",
    "datePublished": "2022-09-13T09:40:57",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.617Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39153 (GCVE-0-2022-39153)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.564Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:08",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39153",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39153",
    "datePublished": "2022-09-13T09:41:08",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.564Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34465 (GCVE-0-2022-34465)
Vulnerability from cvelistv5
Published
2022-07-12 10:07
Modified
2024-08-03 09:15
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.264
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.156Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.264"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.250"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.233"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.250), Parasolid V34.1 (All versions \u003c V34.1.233), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:48",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34465",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.264"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.250"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.233"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.250), Parasolid V34.1 (All versions \u003c V34.1.233), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-243317.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34465",
    "datePublished": "2022-07-12T10:07:20",
    "dateReserved": "2022-06-24T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.156Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39149 (GCVE-0-2022-39149)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17733)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17733)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:04",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39149",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17733)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39149",
    "datePublished": "2022-09-13T09:41:04",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39155 (GCVE-0-2022-39155)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.610Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:09",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39155",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39155",
    "datePublished": "2022-09-13T09:41:09",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.610Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39152 (GCVE-0-2022-39152)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.670Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:07",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39152",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39152",
    "datePublished": "2022-09-13T09:41:07",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.670Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39148 (GCVE-0-2022-39148)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17513)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.633Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17513)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:03",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39148",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17513)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39148",
    "datePublished": "2022-09-13T09:41:04",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.633Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39142 (GCVE-0-2022-39142)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17485)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17485)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:58",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39142",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17485)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39142",
    "datePublished": "2022-09-13T09:40:58",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.643Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39146 (GCVE-0-2022-39146)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
  • CWE-824 - Access of Uninitialized Pointer
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.555Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824: Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39146",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17502)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824: Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39146",
    "datePublished": "2022-09-13T09:41:02",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.555Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39151 (GCVE-0-2022-39151)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2025-06-05 18:20
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.622Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-39151",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-05T18:20:09.285991Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-05T18:20:21.645Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:06.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39151",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39151",
    "datePublished": "2022-09-13T09:41:06.000Z",
    "dateReserved": "2022-09-01T00:00:00.000Z",
    "dateUpdated": "2025-06-05T18:20:21.645Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39144 (GCVE-0-2022-39144)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17494)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.635Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17494)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39144",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17494)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39144",
    "datePublished": "2022-09-13T09:41:00",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.635Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39154 (GCVE-0-2022-39154)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.551Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:08",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39154",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39154",
    "datePublished": "2022-09-13T09:41:09",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.551Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39140 (GCVE-0-2022-39140)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17292)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.571Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17292)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:56",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39140",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17292)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39140",
    "datePublished": "2022-09-13T09:40:56",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.571Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39145 (GCVE-0-2022-39145)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17496)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.614Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17496)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39145",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17496)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39145",
    "datePublished": "2022-09-13T09:41:01",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.614Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39150 (GCVE-0-2022-39150)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17735)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17735)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:05",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39150",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17735)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39150",
    "datePublished": "2022-09-13T09:41:05",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39143 (GCVE-0-2022-39143)
Vulnerability from cvelistv5
Published
2022-09-13 09:40
Modified
2024-08-03 11:10
Severity ?
CWE
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17493)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.623Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17493)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:40:59",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39143",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17493)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787: Out-of-bounds Write"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39143",
    "datePublished": "2022-09-13T09:40:59",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.623Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-39147 (GCVE-0-2022-39147)
Vulnerability from cvelistv5
Published
2022-09-13 09:41
Modified
2024-08-03 11:10
Severity ?
CWE
  • CWE-824 - Access of Uninitialized Pointer
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)
References
Impacted products
Vendor Product Version
Siemens Parasolid V33.1 Version: All versions < V33.1.262
Create a notification for this product.
   Siemens Parasolid V33.1 Version: All versions >= V33.1.262 < V33.1.263
Create a notification for this product.
   Siemens Parasolid V34.0 Version: All versions < V34.0.252
Create a notification for this product.
   Siemens Parasolid V34.1 Version: All versions < V34.1.242
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions < V35.0.161
Create a notification for this product.
   Siemens Parasolid V35.0 Version: All versions >= V35.0.161 < V35.0.164
Create a notification for this product.
   Siemens Simcenter Femap V2022.1 Version: All versions < V2022.1.3
Create a notification for this product.
   Siemens Simcenter Femap V2022.2 Version: All versions < V2022.2.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T11:10:32.568Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V33.1.262"
            }
          ]
        },
        {
          "product": "Parasolid V33.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
            }
          ]
        },
        {
          "product": "Parasolid V34.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.0.252"
            }
          ]
        },
        {
          "product": "Parasolid V34.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V34.1.242"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V35.0.161"
            }
          ]
        },
        {
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.1.3"
            }
          ]
        },
        {
          "product": "Simcenter Femap V2022.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2022.2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824: Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-13T09:41:03",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-39147",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V33.1.262"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V33.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.0.252"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V34.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V34.1.242"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V35.0.161"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Parasolid V35.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Simcenter Femap V2022.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2022.2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824: Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-39147",
    "datePublished": "2022-09-13T09:41:03",
    "dateReserved": "2022-09-01T00:00:00",
    "dateUpdated": "2024-08-03T11:10:32.568Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}