Vulnerabilites related to Schneider Electric - StruxureWare Data Center Expert
CVE-2023-25554 (GCVE-0-2023-25554)
Vulnerability from cvelistv5
Published
2023-04-18 20:34
Modified
2025-02-12 16:00
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS
Command Injection') vulnerability exists that allows a local privilege escalation on the appliance
when a maliciously crafted Operating System command is entered on the device.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.269Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25554", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:37:21.602015Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-12T16:00:38.815Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\nA CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS\nCommand Injection\u0027) vulnerability exists that allows a local privilege escalation on the appliance\nwhen a maliciously crafted Operating System command is entered on the device.\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\nA CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS\nCommand Injection\u0027) vulnerability exists that allows a local privilege escalation on the appliance\nwhen a maliciously crafted Operating System command is entered on the device.\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:34:40.438Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25554", "datePublished": "2023-04-18T20:34:40.438Z", "dateReserved": "2023-02-07T17:00:03.780Z", "dateUpdated": "2025-02-12T16:00:38.815Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37198 (GCVE-0-2023-37198)
Vulnerability from cvelistv5
Published
2023-07-12 06:44
Modified
2024-11-07 14:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
could cause remote code execution when an admin user on DCE uploads or tampers with install
packages.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: v7.9.3 and earlier |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:33.057Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "struxureware_data_center_expert", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "7.9.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37198", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-07T14:42:18.221049Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-07T14:45:30.711Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "v7.9.3 and earlier" } ] } ], "datePublic": "2023-07-11T06:22:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE uploads or tampers with install\npackages. \n\n \n\n\n\n" } ], "value": "\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE uploads or tampers with install\npackages. \n\n \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-12T06:44:34.037Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-37198", "datePublished": "2023-07-12T06:44:34.037Z", "dateReserved": "2023-06-28T14:14:13.863Z", "dateUpdated": "2024-11-07T14:45:30.711Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25555 (GCVE-0-2023-25555)
Vulnerability from cvelistv5
Published
2023-04-18 20:39
Modified
2025-02-05 21:39
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS
Command Injection') vulnerability exists that could allow a user that knows the credentials to
execute unprivileged shell commands on the appliance over SSH.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.309Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25555", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T21:39:21.556512Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T21:39:36.172Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nA CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS\nCommand Injection\u0027) vulnerability exists that could allow a user that knows the credentials to\nexecute unprivileged shell commands on the appliance over SSH. \n\n \n\n\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nA CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS\nCommand Injection\u0027) vulnerability exists that could allow a user that knows the credentials to\nexecute unprivileged shell commands on the appliance over SSH. \n\n \n\n\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:39:14.874Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25555", "datePublished": "2023-04-18T20:39:14.874Z", "dateReserved": "2023-02-07T17:00:03.780Z", "dateUpdated": "2025-02-05T21:39:36.172Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37196 (GCVE-0-2023-37196)
Vulnerability from cvelistv5
Published
2023-07-12 06:22
Modified
2024-11-07 14:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command
('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to
access unauthorized content, change, or delete content, or perform unauthorized actions when
tampering with the alert settings of endpoints on DCE.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: v7.9.3 and earlier |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:32.952Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "struxureware_data_center_expert", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "7.9.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37196", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-07T14:42:31.489133Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-07T14:46:44.245Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "v7.9.3 and earlier" } ] } ], "datePublic": "2023-07-11T06:22:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the alert settings of endpoints on DCE.\n\n" } ], "value": "\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the alert settings of endpoints on DCE.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-12T06:22:46.848Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-37196", "datePublished": "2023-07-12T06:22:46.848Z", "dateReserved": "2023-06-28T14:14:13.863Z", "dateUpdated": "2024-11-07T14:46:44.245Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37199 (GCVE-0-2023-37199)
Vulnerability from cvelistv5
Published
2023-07-12 07:04
Modified
2024-11-07 14:44
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
could cause remote code execution when an admin user on DCE tampers with backups which
are then manually restored.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: v7.9.3 and earlier |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:33.130Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "struxureware_data_center_expert", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "7.9.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37199", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-07T14:42:11.667073Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-07T14:44:46.940Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "v7.9.3 and earlier" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE tampers with backups which\nare then manually restored. \n\n\n" } ], "value": "\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE tampers with backups which\nare then manually restored. \n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-12T07:04:08.510Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-37199", "datePublished": "2023-07-12T07:04:08.510Z", "dateReserved": "2023-06-28T14:14:13.863Z", "dateUpdated": "2024-11-07T14:44:46.940Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25551 (GCVE-0-2023-25551)
Vulnerability from cvelistv5
Published
2023-04-18 20:37
Modified
2025-02-12 16:01
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site
Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters
over HTTP.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.227Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25551", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:26:49.222347Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-12T16:01:18.080Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists on a DCE file upload endpoint when tampering with parameters\nover HTTP.\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\n\n\n\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists on a DCE file upload endpoint when tampering with parameters\nover HTTP.\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:37:23.329Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25551", "datePublished": "2023-04-18T20:37:23.329Z", "dateReserved": "2023-02-07T17:00:03.778Z", "dateUpdated": "2025-02-12T16:01:18.080Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22795 (GCVE-0-2021-22795)
Vulnerability from cvelistv5
Published
2022-03-28 16:25
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - OS Command Injection
Summary
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: unspecified < V7.8.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.444Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.8.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-28T16:25:23", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22795", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "StruxureWare Data Center Expert", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "V7.8.1" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22795", "datePublished": "2022-03-28T16:25:23", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.444Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25552 (GCVE-0-2023-25552)
Vulnerability from cvelistv5
Published
2023-04-18 20:33
Modified
2025-03-03 19:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-862 - Missing Authorization
Summary
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized
content, changes or deleting of content, or performing unauthorized functions when tampering
the Device File Transfer settings on DCE endpoints.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.289Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25552", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-03T17:37:15.543688Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-03T19:16:53.079Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\nA CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized\ncontent, changes or deleting of content, or performing unauthorized functions when tampering\nthe Device File Transfer settings on DCE endpoints. \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\nA CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized\ncontent, changes or deleting of content, or performing unauthorized functions when tampering\nthe Device File Transfer settings on DCE endpoints. \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-862", "description": "CWE-862 Missing Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:33:50.548Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25552", "datePublished": "2023-04-18T20:33:50.548Z", "dateReserved": "2023-02-07T17:00:03.778Z", "dateUpdated": "2025-03-03T19:16:53.079Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25550 (GCVE-0-2023-25550)
Vulnerability from cvelistv5
Published
2023-04-18 20:36
Modified
2025-02-12 16:00
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
allows remote code execution via the “hostname” parameter when maliciously crafted hostname
syntax is entered.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:18.948Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25550", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:34:20.655945Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-12T16:00:58.860Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\nallows remote code execution via the \u201chostname\u201d parameter when maliciously crafted hostname\nsyntax is entered.\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\nallows remote code execution via the \u201chostname\u201d parameter when maliciously crafted hostname\nsyntax is entered.\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:36:30.681Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25550", "datePublished": "2023-04-18T20:36:30.681Z", "dateReserved": "2023-02-07T17:00:03.778Z", "dateUpdated": "2025-02-12T16:00:58.860Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25549 (GCVE-0-2023-25549)
Vulnerability from cvelistv5
Published
2023-04-18 20:35
Modified
2025-03-03 19:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that
allows for remote code execution when using a parameter of the DCE network settings
endpoint.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.200Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25549", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-03T19:14:12.740311Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-03T19:14:28.433Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\nallows for remote code execution when using a parameter of the DCE network settings\nendpoint. \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\nallows for remote code execution when using a parameter of the DCE network settings\nendpoint. \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:35:42.008Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25549", "datePublished": "2023-04-18T20:35:42.008Z", "dateReserved": "2023-02-07T17:00:03.778Z", "dateUpdated": "2025-03-03T19:14:28.433Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37197 (GCVE-0-2023-37197)
Vulnerability from cvelistv5
Published
2023-07-12 06:41
Modified
2024-11-07 14:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Summary
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command
('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to
access unauthorized content, change, or delete content, or perform unauthorized actions when
tampering with the mass configuration settings of endpoints on DCE.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: v7.9.3 and earlier |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:33.407Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "struxureware_data_center_expert", "vendor": "schneider-electric", "versions": [ { "lessThanOrEqual": "7.9.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37197", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-07T14:42:24.492097Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-07T14:46:11.017Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert ", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "v7.9.3 and earlier" } ] } ], "datePublic": "2023-07-11T06:22:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the mass configuration settings of endpoints on DCE. \n\n\n\n" } ], "value": "\n\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the mass configuration settings of endpoints on DCE. \n\n\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-12T06:41:30.783Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-37197", "datePublished": "2023-07-12T06:41:30.783Z", "dateReserved": "2023-06-28T14:14:13.863Z", "dateUpdated": "2024-11-07T14:46:11.017Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25548 (GCVE-0-2023-25548)
Vulnerability from cvelistv5
Published
2023-04-18 20:32
Modified
2025-03-03 19:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-863 - Incorrect Authorization
Summary
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device
credentials on specific DCE endpoints not being properly secured when a hacker is using a low
privileged user.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.192Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25548", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T19:05:12.580316Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-03T19:17:53.318Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\nA CWE-863: Incorrect Authorization vulnerability exists that could allow access to device\ncredentials on specific DCE endpoints not being properly secured when a hacker is using a low\nprivileged user. \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could allow access to device\ncredentials on specific DCE endpoints not being properly secured when a hacker is using a low\nprivileged user. \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-863", "description": "CWE-863 Incorrect Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:32:42.718Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25548", "datePublished": "2023-04-18T20:32:42.718Z", "dateReserved": "2023-02-07T17:00:03.777Z", "dateUpdated": "2025-03-03T19:17:53.318Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25553 (GCVE-0-2023-25553)
Vulnerability from cvelistv5
Published
2023-04-18 20:38
Modified
2025-02-05 21:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site
Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the
webserver.
Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.183Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25553", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T21:24:40.357327Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-05T21:24:51.230Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\n\n\n\n\n\n\n\n\n\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists on a DCE endpoint through the logging capabilities of the\nwebserver. \n\n\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\n\n\n\n\n\n\n\n\n\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists on a DCE endpoint through the logging capabilities of the\nwebserver. \n\n\n\n\n\n \n\n\n\n\n \n\n \n\n Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:38:01.298Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25553", "datePublished": "2023-04-18T20:38:01.298Z", "dateReserved": "2023-02-07T17:00:03.779Z", "dateUpdated": "2025-02-05T21:24:51.230Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25547 (GCVE-0-2023-25547)
Vulnerability from cvelistv5
Published
2023-04-18 20:31
Modified
2025-02-12 16:00
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-863 - Incorrect Authorization
Summary
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution
on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: All < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:18.954Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25547", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:40:43.256138Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-12T16:00:20.177Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThanOrEqual": "V7.9.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "datePublic": "2023-02-14T08:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\n\nA CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution\non upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\u003c/p\u003e" } ], "value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution\non upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-863", "description": "CWE-863 Incorrect Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-18T20:31:35.199Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-02.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-25547", "datePublished": "2023-04-18T20:31:35.199Z", "dateReserved": "2023-02-07T17:00:03.777Z", "dateUpdated": "2025-02-12T16:00:20.177Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22794 (GCVE-0-2021-22794)
Vulnerability from cvelistv5
Published
2022-03-28 16:25
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | StruxureWare Data Center Expert |
Version: unspecified < V7.8.1 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.441Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "StruxureWare Data Center Expert", "vendor": "Schneider Electric", "versions": [ { "lessThan": "V7.8.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-28T16:25:21", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22794", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "StruxureWare Data Center Expert", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "V7.8.1" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.1, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22794", "datePublished": "2022-03-28T16:25:21", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.441Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }