Vulnerabilites related to F5 - Traffix SDC
CVE-2022-27662 (GCVE-0-2022-27662)
Vulnerability from cvelistv5
Published
2022-05-05 16:29
Modified
2024-09-16 20:16
CWE
  • CWE-1336 - Improper Neutralization of Special Elements Used in a Template Engine
Summary
On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
References
Impacted products
Vendor Product Version
F5 Traffix SDC Version: 5.2.x   < 5.2.2
Version: 5.1.x   < 5.1.35
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:32:59.915Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K24248011"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Traffix SDC",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "5.2.2",
              "status": "affected",
              "version": "5.2.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.1.35",
              "status": "affected",
              "version": "5.1.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1336",
              "description": "CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:29:10",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K24248011"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T19:45:00.000Z",
          "ID": "CVE-2022-27662",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Traffix SDC",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.2.x",
                            "version_value": "5.2.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.1.x",
                            "version_value": "5.1.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Template Injection vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute template language-specific instructions in the context of the server. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-1336 Improper Neutralization of Special Elements Used in a Template Engine"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K24248011",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K24248011"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-27662",
    "datePublished": "2022-05-05T16:29:10.065731Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-16T20:16:37.864Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27880 (GCVE-0-2022-27880)
Vulnerability from cvelistv5
Published
2022-05-05 16:32
Modified
2024-09-17 04:00
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Summary
On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
References
Impacted products
Vendor Product Version
F5 Traffix SDC Version: 5.2.x   < 5.2.2
Version: 5.1.x   < 5.1.35
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:41:10.976Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K17341495"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Traffix SDC",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "5.2.2",
              "status": "affected",
              "version": "5.2.x",
              "versionType": "custom"
            },
            {
              "lessThan": "5.1.35",
              "status": "affected",
              "version": "5.1.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
        }
      ],
      "datePublic": "2022-05-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-05T16:32:33",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K17341495"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "DATE_PUBLIC": "2022-05-04T14:00:00.000Z",
          "ID": "CVE-2022-27880",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Traffix SDC",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.2.x",
                            "version_value": "5.2.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "5.1.x",
                            "version_value": "5.1.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "F5"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "F5 acknowledges TIM Security Red Team Research, Valerio Alessandroni, Matteo Brutti, and Massimiliano Brolli for bringing this issue to our attention and following the highest standards of coordinated disclosure."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "On F5 Traffix SDC 5.2.x versions prior to 5.2.2 and 5.1.x versions prior to 5.1.35, a stored Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the Traffix SDC Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K17341495",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K17341495"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2022-27880",
    "datePublished": "2022-05-05T16:32:33.813504Z",
    "dateReserved": "2022-04-19T00:00:00",
    "dateUpdated": "2024-09-17T04:00:20.047Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}