Vulnerabilites related to phoenixcontact - config\+
CVE-2023-46143 (GCVE-0-2023-46143)
Vulnerability from cvelistv5
Published
2023-12-14 14:06
Modified
2025-05-22 17:39
CWE
  • CWE-494 - Download of Code Without Integrity Check
Summary
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.
Impacted products
Vendor Product Version
PHOENIX CONTACT Automation Worx Software Suite Version: all
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:37:39.880Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-46143",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-22T17:39:21.470279Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-22T17:39:45.716Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Automation Worx Software Suite",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC 1050",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC 1050 XC",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC 3050",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Config+",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FC 350 PCI ETH",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC1x0",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC1x1",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC 3xx",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx Express",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC WORX RT BASIC",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC WORX SRT",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 430 ETH-IB",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 450 ETH-IB",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 460R PN 3TX",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 470S PN 3TX",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 480S PN 4TX",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Reid Wightman of Dragos, Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
            }
          ],
          "value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494 Download of Code Without Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-14T14:07:36.807Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
        }
      ],
      "source": {
        "advisory": "VDE-2023-057",
        "defect": [
          "CERT@VDE#64610"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-46143",
    "datePublished": "2023-12-14T14:06:06.479Z",
    "dateReserved": "2023-10-17T07:04:03.576Z",
    "dateUpdated": "2025-05-22T17:39:45.716Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-16675 (GCVE-0-2019-16675)
Vulnerability from cvelistv5
Published
2019-10-31 21:22
Modified
2024-08-05 01:17
Severity ?
CWE
  • n/a
Summary
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:17:41.063Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en-us/advisories"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-922/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-302-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-991/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2019-10-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-26T15:07:08",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert.vde.com/en-us/advisories"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-922/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-302-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-991/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-16675",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en-us/advisories",
              "refsource": "MISC",
              "url": "https://cert.vde.com/en-us/advisories"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-922/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-922/"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-302-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-302-01"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-991/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-991/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-16675",
    "datePublished": "2019-10-31T21:22:59",
    "dateReserved": "2019-09-21T00:00:00",
    "dateUpdated": "2024-08-05T01:17:41.063Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-46141 (GCVE-0-2023-46141)
Vulnerability from cvelistv5
Published
2023-12-14 14:05
Modified
2024-08-02 20:37
Severity ?
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.
Impacted products
Vendor Product Version
PHOENIX CONTACT Automation Worx Software Suite Version: all
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:37:39.537Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2023-055/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Automation Worx Software Suite",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC 1050",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC 1050 XC",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AXC 3050",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Config+",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FC 350 PCI ETH",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC1x0",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC1x1",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC 3xx",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx Express",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC WORX RT BASIC",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC WORX SRT",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 430 ETH-IB",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 450 ETH-IB",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 460R PN 3TX",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 470S PN 3TX",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RFC 480S PN 4TX",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Reid Wightman of Dragos, Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device."
            }
          ],
          "value": "Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-14T14:05:11.292Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2023-055/"
        }
      ],
      "source": {
        "advisory": "VDE-2023-055",
        "defect": [
          "CERT@VDE#64608"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Phoenix Contact: Automation Worx and classic line controllers prone to Incorrect Permission Assignment for Critical Resource",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2023-46141",
    "datePublished": "2023-12-14T14:05:11.292Z",
    "dateReserved": "2023-10-17T07:04:03.576Z",
    "dateUpdated": "2024-08-02T20:37:39.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33542 (GCVE-0-2021-33542)
Vulnerability from cvelistv5
Published
2021-06-25 18:26
Modified
2024-09-17 01:31
CWE
  • CWE-824 - Access of Uninitialized Pointer
Summary
Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected.
Impacted products
Vendor Product Version
Phoenix Contact Automation Worx Software Suite Version: PC Worx   <
Version: PC Worx Express   <
Version: Config+   <
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:50:43.120Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Automation Worx Software Suite",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThanOrEqual": "1.87",
              "status": "affected",
              "version": "PC Worx",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "1.87",
              "status": "affected",
              "version": "PC Worx Express",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "1.87",
              "status": "affected",
              "version": "Config+",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "The vulnerability was discovered by Francis Provencher {PRL} and reported by Zero Day Initiative (ZDI) as ZDI-CAN-13134. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
        }
      ],
      "datePublic": "2021-06-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-07T09:06:35",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Temporary Fix / Mitigation\nWe strongly recommend customers to exchange project files only using secure file exchange services. Project files should not be exchanged via unencrypted email.\n\nRemediation\nWith the next version of Automationworx Software Suite the affected data will be initialized completely and thereby freeing of unallocated memory will be prevented."
        }
      ],
      "source": {
        "advisory": "VDE-2021-020",
        "defect": [
          "VDE-2021-020"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Phoenix Contact: Automation Worx Software Suite affected by Remote Code Execution (RCE) vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2021-06-23T10:00:00.000Z",
          "ID": "CVE-2021-33542",
          "STATE": "PUBLIC",
          "TITLE": "Phoenix Contact: Automation Worx Software Suite affected by Remote Code Execution (RCE) vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Automation Worx Software Suite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "PC Worx",
                            "version_value": "1.87"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "PC Worx Express",
                            "version_value": "1.87"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "Config+",
                            "version_value": "1.87"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Phoenix Contact"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "The vulnerability was discovered by Francis Provencher {PRL} and reported by Zero Day Initiative (ZDI) as ZDI-CAN-13134. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-824 Access of Uninitialized Pointer"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en-us/advisories/vde-2021-020",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Temporary Fix / Mitigation\nWe strongly recommend customers to exchange project files only using secure file exchange services. Project files should not be exchanged via unencrypted email.\n\nRemediation\nWith the next version of Automationworx Software Suite the affected data will be initialized completely and thereby freeing of unallocated memory will be prevented."
          }
        ],
        "source": {
          "advisory": "VDE-2021-020",
          "defect": [
            "VDE-2021-020"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-33542",
    "datePublished": "2021-06-25T18:26:06.409806Z",
    "dateReserved": "2021-05-24T00:00:00",
    "dateUpdated": "2024-09-17T01:31:44.718Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2023-12-14 14:15
Modified
2024-11-21 08:27
Summary
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:automationworx_software_suite:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9797B615-825F-4CAA-B36E-5161E37FAF9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_1050_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D586DC-2274-4A32-AE98-7BE174C230CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_1050:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F55C821-DAA6-4098-BB54-80F6D9ED0CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_1050_xc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "332A6164-CDC1-4DBF-9B62-946EC7D7C4B3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_1050_xc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E03B5234-36FA-4BCE-964D-F55FFFD5CAAC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_3050_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84066F7B-8306-4743-9F12-75B8F880AD93",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_3050:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB9699A2-782D-40F3-B8D6-3C315104BA60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:config\\+:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6D8FDB6-6181-49EB-BE6D-236D39A478A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:fc_350_pci_eth_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEB7CA5B-7EEF-4E0E-9A53-83FE28730852",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:fc_350_pci_eth:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4BB6654-41BB-488E-AC8C-E74C05CA198F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc1x0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AC07A81-D5D6-449C-93F8-93D6E87487DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc1x0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE45F6AF-7286-48F7-B4BE-AFC948884C7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc1x1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E168AB1-1B81-4990-95E4-56C36275609B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc1x1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E318A8B-D1D1-4DD5-AF71-DCBFEFCF2C5E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_3xx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65E1A201-E7B1-452B-8BC6-A355A3BF9460",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_3xx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF1C58A6-5220-4509-B426-D1ED5ECFAD05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B975C4E4-83B5-4C98-811B-E6D13687AB85",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx_express:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE663FFA-4B82-4477-A424-4C9CC83C131E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:pc_worx_rt_basic_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8693B231-3A5C-47B7-BEA5-53D430BBACF4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:pc_worx_rt_basic:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08B214FC-776F-454B-8DC4-E7F2E6EFB013",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx_srt:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2A6F462-A12F-4E08-9AA6-1C1AF743A645",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_430_eth-ib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643E47A5-E7AA-4321-99A1-05EEBD9A2B56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_430_eth-ib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F32F262-519C-41BB-BF31-ECBCAC1ABEA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_450_eth-ib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A91E019B-F0C5-4DF0-AE4C-E60F3D598F0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_450_eth-ib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3C2EDF4-2982-4858-A960-7E7564E5B20A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_460r_pn_3tx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "302995A9-E9CC-4477-B374-CE10F16A5E10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_460r_pn_3tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7544E2C-2E63-4C36-AB64-764B4393E377",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_470s_pn_3tx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCAB2CA6-EEC4-4E0D-B962-FC2C4EF06013",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_470s_pn_3tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD94CBFF-CC25-4122-96FE-2308A4D1659D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_480s_pn_4tx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B383246-EF0A-466F-89EA-F61AFC447509",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_480s_pn_4tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B043176-58CC-438C-92D9-99F479BB1C58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de descarga de c\u00f3digo sin verificaci\u00f3n de integridad en los PLC de la l\u00ednea cl\u00e1sica de PHOENIX CONTACT permite que un atacante remoto no autenticado modifique algunas o todas las aplicaciones en un PLC."
    }
  ],
  "id": "CVE-2023-46143",
  "lastModified": "2024-11-21T08:27:58.220",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "info@cert.vde.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-12-14T14:15:43.207",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-494"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-12-14 14:15
Modified
2024-11-21 08:27
Severity ?
Summary
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:automationworx_software_suite:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9797B615-825F-4CAA-B36E-5161E37FAF9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_1050_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D586DC-2274-4A32-AE98-7BE174C230CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_1050:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F55C821-DAA6-4098-BB54-80F6D9ED0CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_1050_xc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "332A6164-CDC1-4DBF-9B62-946EC7D7C4B3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_1050_xc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E03B5234-36FA-4BCE-964D-F55FFFD5CAAC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:axc_3050_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84066F7B-8306-4743-9F12-75B8F880AD93",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:axc_3050:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB9699A2-782D-40F3-B8D6-3C315104BA60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:config\\+:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6D8FDB6-6181-49EB-BE6D-236D39A478A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:fc_350_pci_eth_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEB7CA5B-7EEF-4E0E-9A53-83FE28730852",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:fc_350_pci_eth:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4BB6654-41BB-488E-AC8C-E74C05CA198F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc1x0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AC07A81-D5D6-449C-93F8-93D6E87487DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc1x0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE45F6AF-7286-48F7-B4BE-AFC948884C7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc1x1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E168AB1-1B81-4990-95E4-56C36275609B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc1x1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E318A8B-D1D1-4DD5-AF71-DCBFEFCF2C5E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:ilc_3xx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65E1A201-E7B1-452B-8BC6-A355A3BF9460",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:ilc_3xx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF1C58A6-5220-4509-B426-D1ED5ECFAD05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B975C4E4-83B5-4C98-811B-E6D13687AB85",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx_express:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE663FFA-4B82-4477-A424-4C9CC83C131E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:pc_worx_rt_basic_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8693B231-3A5C-47B7-BEA5-53D430BBACF4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:pc_worx_rt_basic:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08B214FC-776F-454B-8DC4-E7F2E6EFB013",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx_srt:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2A6F462-A12F-4E08-9AA6-1C1AF743A645",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_430_eth-ib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643E47A5-E7AA-4321-99A1-05EEBD9A2B56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_430_eth-ib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F32F262-519C-41BB-BF31-ECBCAC1ABEA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_450_eth-ib_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A91E019B-F0C5-4DF0-AE4C-E60F3D598F0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_450_eth-ib:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3C2EDF4-2982-4858-A960-7E7564E5B20A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_460r_pn_3tx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "302995A9-E9CC-4477-B374-CE10F16A5E10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_460r_pn_3tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7544E2C-2E63-4C36-AB64-764B4393E377",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_470s_pn_3tx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCAB2CA6-EEC4-4E0D-B962-FC2C4EF06013",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_470s_pn_3tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD94CBFF-CC25-4122-96FE-2308A4D1659D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:phoenixcontact:rfc_480s_pn_4tx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B383246-EF0A-466F-89EA-F61AFC447509",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:phoenixcontact:rfc_480s_pn_4tx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B043176-58CC-438C-92D9-99F479BB1C58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device."
    },
    {
      "lang": "es",
      "value": "La asignaci\u00f3n de permisos incorrecta para una vulnerabilidad de recursos cr\u00edticos en varios productos de la l\u00ednea cl\u00e1sica de PHOENIX CONTACT permite que un atacante remoto no autenticado obtenga acceso completo al dispositivo afectado."
    }
  ],
  "id": "CVE-2023-46141",
  "lastModified": "2024-11-21T08:27:57.923",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "info@cert.vde.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-12-14T14:15:42.767",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2023-055/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en/advisories/VDE-2023-055/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-10-31 22:15
Modified
2024-11-21 04:30
Summary
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:config\\+:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF8F3DA4-114D-4378-A575-DC1FA56B3D2C",
              "versionEndIncluding": "1.86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2743AE1-C0F5-48FA-92B1-B0FE9E1AD54F",
              "versionEndIncluding": "1.86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx_express:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FD22718-F9F5-48F0-BCE7-694E340E83CA",
              "versionEndIncluding": "1.86",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema en PHOENIX CONTACT PC Worx versiones hasta 1.86, PC Worx Express versiones hasta 1.86 y Config+ versiones hasta 1.86. Un archivo de proyecto de PC Worx o Config+ manipulado podr\u00eda conllevar a una lectura fuera de l\u00edmites y a una ejecuci\u00f3n de c\u00f3digo remota. El atacante necesita conseguir acceso a un proyecto original de PC Worx o Config+ para poder manipular los datos en su interior. Luego de la manipulaci\u00f3n, el atacante necesita intercambiar los archivos originales por los manipulados en la estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones."
    }
  ],
  "id": "CVE-2019-16675",
  "lastModified": "2024-11-21T04:30:57.417",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-10-31T22:15:10.567",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en-us/advisories"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-302-01"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-922/"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-991/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en-us/advisories"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-302-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-922/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-991/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-06-25 19:15
Modified
2024-11-21 06:09
Summary
Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:phoenixcontact:config\\+:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D2D0ACE-D2B7-4124-900B-0FBB0830563F",
              "versionEndIncluding": "1.87",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73C5830F-A865-48CB-8DEE-126204CCF0C1",
              "versionEndIncluding": "1.87",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:phoenixcontact:pc_worx_express:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "613450E9-39B4-4D97-BB64-A3AE3B7ECCA9",
              "versionEndIncluding": "1.87",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected."
    },
    {
      "lang": "es",
      "value": "Phoenix Contact Classic Automation Worx Software Suite en versiones 1.87 y anteriores, est\u00e1 afectado por una vulnerabilidad de ejecuci\u00f3n de c\u00f3digo remota. La manipulaci\u00f3n de proyectos de PC Worx o Config+ podr\u00eda conllevar a una ejecuci\u00f3n de c\u00f3digo remota cuando es liberada una memoria no asignada debido a datos inicializados de forma incompleta. El atacante necesita conseguir acceso a un archivo de configuraci\u00f3n de bus original (*.bcp) para poder manipular los datos en su interior. Despu\u00e9s de la manipulaci\u00f3n, el atacante necesita intercambiar el archivo original por el manipulado en la estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones. La disponibilidad, la integridad o la confidencialidad de una estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones podr\u00eda estar comprometida por ataques usando estas vulnerabilidades. Los sistemas automatizados en funcionamiento que fueron programados con uno de los productos mencionados no est\u00e1n afectados"
    }
  ],
  "id": "CVE-2021-33542",
  "lastModified": "2024-11-21T06:09:03.027",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "HIGH",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 4.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "info@cert.vde.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.0,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-06-25T19:15:09.817",
  "references": [
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
    },
    {
      "source": "info@cert.vde.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert.vde.com/en-us/advisories/vde-2021-020"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-782/"
    }
  ],
  "sourceIdentifier": "info@cert.vde.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "info@cert.vde.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-824"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}