Vulnerabilites related to honeywell - experion_process_knowledge_system
CVE-2014-9186 (GCVE-0-2014-9186)
Vulnerability from cvelistv5
Published
2019-04-08 15:09
Modified
2024-08-06 13:40
Severity ?
CWE
Summary
A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
Impacted products
Vendor Product Version
Honeywell Experion PKS Version: R40x before R400.6
Version: R41x before R410.6
Version: R43x before R430.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:24.560Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Experion PKS",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "R40x before R400.6"
            },
            {
              "status": "affected",
              "version": "R41x before R410.6"
            },
            {
              "status": "affected",
              "version": "R43x before R430.2"
            }
          ]
        }
      ],
      "datePublic": "2014-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-98",
              "description": "File inclusion CWE-98",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-08T15:09:55",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9186",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Experion PKS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "R40x before R400.6"
                          },
                          {
                            "version_value": "R41x before R410.6"
                          },
                          {
                            "version_value": "R43x before R430.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Honeywell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "File inclusion CWE-98"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9186",
    "datePublished": "2019-04-08T15:09:55",
    "dateReserved": "2014-12-02T00:00:00",
    "dateUpdated": "2024-08-06T13:40:24.560Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-9189 (GCVE-0-2014-9189)
Vulnerability from cvelistv5
Published
2019-03-25 19:10
Modified
2024-08-06 13:40
Severity ?
CWE
  • CWE-121 - Stack-based buffer overflow
Summary
Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
Impacted products
Vendor Product Version
Honeywell Experion PKS Version: R40x prior to R400.6
Version: R41x prior to R410.6
Version: R43x prior to R430.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:23.163Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Experion PKS",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "R40x prior to R400.6"
            },
            {
              "status": "affected",
              "version": "R41x prior to R410.6"
            },
            {
              "status": "affected",
              "version": "R43x prior to R430.2"
            }
          ]
        }
      ],
      "datePublic": "2014-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based buffer overflow CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-25T19:10:47",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9189",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Experion PKS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "R40x prior to R400.6"
                          },
                          {
                            "version_value": "R41x prior to R410.6"
                          },
                          {
                            "version_value": "R43x prior to R430.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Honeywell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9189",
    "datePublished": "2019-03-25T19:10:47",
    "dateReserved": "2014-12-02T00:00:00",
    "dateUpdated": "2024-08-06T13:40:23.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-9187 (GCVE-0-2014-9187)
Vulnerability from cvelistv5
Published
2019-03-25 19:19
Modified
2024-08-06 13:40
Severity ?
CWE
  • CWE-122 - Heap-based buffer overflow
Summary
Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
Impacted products
Vendor Product Version
Honeywell Experion PKS Version: R40x prior to R400.6
Version: R41x prior to R410.6
Version: R43x prior to R430.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:24.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Experion PKS",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "R40x prior to R400.6"
            },
            {
              "status": "affected",
              "version": "R41x prior to R410.6"
            },
            {
              "status": "affected",
              "version": "R43x prior to R430.2"
            }
          ]
        }
      ],
      "datePublic": "2014-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "Heap-based buffer overflow CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-25T19:19:10",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9187",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Experion PKS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "R40x prior to R400.6"
                          },
                          {
                            "version_value": "R41x prior to R410.6"
                          },
                          {
                            "version_value": "R43x prior to R430.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Honeywell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9187",
    "datePublished": "2019-03-25T19:19:10",
    "dateReserved": "2014-12-02T00:00:00",
    "dateUpdated": "2024-08-06T13:40:24.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5435 (GCVE-0-2014-5435)
Vulnerability from cvelistv5
Published
2019-04-08 15:25
Modified
2024-08-06 11:41
Severity ?
CWE
Summary
An arbitrary memory write vulnerability exists in the dual_onsrv.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, that could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
Impacted products
Vendor Product Version
Honeywell Experion PKS Version: R40x before R400.6
Version: R41x before R410.6
Version: R43x before R430.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.065Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Experion PKS",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "R40x before R400.6"
            },
            {
              "status": "affected",
              "version": "R41x before R410.6"
            },
            {
              "status": "affected",
              "version": "R43x before R430.2"
            }
          ]
        }
      ],
      "datePublic": "2014-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An arbitrary memory write vulnerability exists in the dual_onsrv.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, that could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-123",
              "description": "Arbitrary memory write CWE-123",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-08T15:25:17",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5435",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Experion PKS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "R40x before R400.6"
                          },
                          {
                            "version_value": "R41x before R410.6"
                          },
                          {
                            "version_value": "R43x before R430.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Honeywell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An arbitrary memory write vulnerability exists in the dual_onsrv.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, that could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Arbitrary memory write CWE-123"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5435",
    "datePublished": "2019-04-08T15:25:17",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2024-08-06T11:41:49.065Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-8344 (GCVE-0-2016-8344)
Vulnerability from cvelistv5
Published
2017-02-13 21:00
Modified
2024-08-06 02:20
Severity ?
CWE
  • Honeywell Experion PKS Improper Input Validation Vulnerability
Summary
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.
References
Impacted products
Vendor Product Version
n/a Honeywell Experion PKS through 431 Version: Honeywell Experion PKS through 431
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T02:20:30.912Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-301-01"
          },
          {
            "name": "93950",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/93950"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Honeywell Experion PKS through 431",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Honeywell Experion PKS through 431"
            }
          ]
        }
      ],
      "datePublic": "2017-02-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Honeywell Experion PKS Improper Input Validation Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-02-14T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-301-01"
        },
        {
          "name": "93950",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/93950"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2016-8344",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Honeywell Experion PKS through 431",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Honeywell Experion PKS through 431"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Honeywell Experion PKS Improper Input Validation Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-301-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-301-01"
            },
            {
              "name": "93950",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/93950"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-8344",
    "datePublished": "2017-02-13T21:00:00",
    "dateReserved": "2016-09-28T00:00:00",
    "dateUpdated": "2024-08-06T02:20:30.912Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5436 (GCVE-0-2014-5436)
Vulnerability from cvelistv5
Published
2019-04-08 15:18
Modified
2024-08-06 11:41
Severity ?
CWE
  • CWE-22 - Directory traversal
Summary
A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
Impacted products
Vendor Product Version
Honeywell Experion PKS Version: R40x before R400.6
Version: R41x before R410.6
Version: R43x before R430.2
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Experion PKS",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "R40x before R400.6"
            },
            {
              "status": "affected",
              "version": "R41x before R410.6"
            },
            {
              "status": "affected",
              "version": "R43x before R430.2"
            }
          ]
        }
      ],
      "datePublic": "2014-12-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "Directory traversal CWE-22",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-08T15:18:41",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5436",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Experion PKS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "R40x before R400.6"
                          },
                          {
                            "version_value": "R41x before R410.6"
                          },
                          {
                            "version_value": "R43x before R430.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Honeywell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Directory traversal CWE-22"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5436",
    "datePublished": "2019-04-08T15:18:41",
    "dateReserved": "2014-08-22T00:00:00",
    "dateUpdated": "2024-08-06T11:41:49.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2019-04-08 16:29
Modified
2024-11-21 02:20
Severity ?
Summary
A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E83AB48A-F78A-4D8E-8833-DFD95946F16A",
              "versionEndExcluding": "r400.6",
              "versionStartIncluding": "r400",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "899CC094-462B-4862-97D6-DAF1BDD70B5C",
              "versionEndExcluding": "r410.6",
              "versionStartIncluding": "r410",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19429BFB-4485-4F36-9DF9-3BD83DE3F1FD",
              "versionEndExcluding": "r430.2",
              "versionStartIncluding": "r430",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de inclusi\u00f3n de archivos en el m\u00f3dulo confd.exe en Honeywell Experion PKS R40x anterior a R400.6, R41x anterior a R410.6 y R43x anterior a R430.2, lo que podr\u00eda conllevar a aceptar un archivo arbitrario en la funci\u00f3n y la posible divulgaci\u00f3n de informaci\u00f3n o ejecuci\u00f3n de c\u00f3digo remoto . Honeywell exhorta encarecidamente y recomienda a todos los clientes que ejecutan versiones no compatibles de EKPS anterior a R400 a actualizar a una versi\u00f3n compatible."
    }
  ],
  "id": "CVE-2014-9186",
  "lastModified": "2024-11-21T02:20:21.767",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-08T16:29:00.493",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-98"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-02-13 21:59
Modified
2025-04-20 01:37
Summary
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32AD7777-22F4-4099-839B-DAEAA2A5974B",
              "versionEndIncluding": "311",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:410:*:*:*:*:*:*:*",
              "matchCriteriaId": "78596F1B-105A-49E6-BA88-4FD7B3E77F9A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:430:*:*:*:*:*:*:*",
              "matchCriteriaId": "90438882-38D1-4C4E-9018-A42E7E42C4FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:431:*:*:*:*:*:*:*",
              "matchCriteriaId": "D08E8D07-5539-4608-94C7-4A5F44B4EC8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B633CF96-C485-47EC-8986-F090642EA236",
              "versionEndIncluding": "411",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices."
    },
    {
      "lang": "es",
      "value": "Ha sido descubierto un problema en la plataforma Honeywell Experion Process Knowledge System (PKS): Experion PKS, Release 3xx y versiones anteriores, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430 y Experion PKS, Release 431. Experion PKS No valida adecuadamente la entrada. Enviando un paquete especialmente manipulado, un atacante podr\u00eda provocar que el proceso termine. Una explotaci\u00f3n exitosa impedir\u00eda cargas de firmware a los dispositivos de la Serie C."
    }
  ],
  "id": "CVE-2016-8344",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 3.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
          "version": "3.0"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-02-13T21:59:00.610",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/93950"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-301-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/93950"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-301-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-04-08 16:29
Modified
2024-11-21 02:12
Severity ?
Summary
An arbitrary memory write vulnerability exists in the dual_onsrv.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, that could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
ics-cert@hq.dhs.govhttps://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E83AB48A-F78A-4D8E-8833-DFD95946F16A",
              "versionEndExcluding": "r400.6",
              "versionStartIncluding": "r400",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "899CC094-462B-4862-97D6-DAF1BDD70B5C",
              "versionEndExcluding": "r410.6",
              "versionStartIncluding": "r410",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19429BFB-4485-4F36-9DF9-3BD83DE3F1FD",
              "versionEndExcluding": "r430.2",
              "versionStartIncluding": "r430",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An arbitrary memory write vulnerability exists in the dual_onsrv.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, that could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de escritura de memoria arbitraria en el m\u00f3dulo dual_onsrv.exe en Honeywell Experion PKS R40x anterior a R400.6, R41x anterior a R410.6 y R43x anterior a R430.2, lo que podr\u00eda conducir a una posible ejecuci\u00f3n de c\u00f3digo remota  o denegaci\u00f3n de servicio. Honeywell exhorta encarecidamente y recomienda a todos los clientes que ejecutan versiones no compatibles de EKPS anterior a R400 para actualizar a una versi\u00f3n compatible."
    }
  ],
  "id": "CVE-2014-5435",
  "lastModified": "2024-11-21T02:12:02.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-08T16:29:00.307",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-123"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-03-25 20:29
Modified
2024-11-21 02:20
Severity ?
Summary
Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
ics-cert@hq.dhs.govhttps://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E83AB48A-F78A-4D8E-8833-DFD95946F16A",
              "versionEndExcluding": "r400.6",
              "versionStartIncluding": "r400",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "899CC094-462B-4862-97D6-DAF1BDD70B5C",
              "versionEndExcluding": "r410.6",
              "versionStartIncluding": "r410",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19429BFB-4485-4F36-9DF9-3BD83DE3F1FD",
              "versionEndExcluding": "r430.2",
              "versionStartIncluding": "r430",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
    },
    {
      "lang": "es",
      "value": "Existen m\u00faltiples vulnerabilidades de desbordamiento de b\u00fafer basado en pila en Honeywell Experion PKS, en todas la versiones anteriores a la R400.6, todas la versiones anteriores a la R410.6 y todas la versiones anteriores a la R430.2, lo cual podr\u00eda llevar a una posible ejecuci\u00f3n remota de c\u00f3digo, corrupci\u00f3n de memoria din\u00e1mica o denegaci\u00f3n de servicio (DoS). Honeywell recomienda encarecidamente que todos los usuarios que ejecuten versiones sin soporte de EKPS anteriores a la R400 actualicen el producto a una versi\u00f3n soportada."
    }
  ],
  "id": "CVE-2014-9189",
  "lastModified": "2024-11-21T02:20:22.110",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-03-25T20:29:00.300",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-04-08 16:29
Modified
2024-11-21 02:12
Summary
A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
ics-cert@hq.dhs.govhttps://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E83AB48A-F78A-4D8E-8833-DFD95946F16A",
              "versionEndExcluding": "r400.6",
              "versionStartIncluding": "r400",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "899CC094-462B-4862-97D6-DAF1BDD70B5C",
              "versionEndExcluding": "r410.6",
              "versionStartIncluding": "r410",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19429BFB-4485-4F36-9DF9-3BD83DE3F1FD",
              "versionEndExcluding": "r430.2",
              "versionStartIncluding": "r430",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de salto de directorio (directory traversal) en el m\u00f3dulo confd.exe en Honeywell Experion PKS R40x anterior a R400.6, R41x anterior a R410.6 y R43x anterior a R430.2, lo que podr\u00eda conducir a una posible divulgaci\u00f3n de informaci\u00f3n. Honeywell exhorta encarecidamente y recomienda a todos los clientes que ejecutan versiones no compatibles de EKPS anterior a R400 a actualizar a una versi\u00f3n compatible."
    }
  ],
  "id": "CVE-2014-5436",
  "lastModified": "2024-11-21T02:12:02.797",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-08T16:29:00.417",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-03-25 20:29
Modified
2024-11-21 02:20
Severity ?
Summary
Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
References
ics-cert@hq.dhs.govhttps://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01Mitigation, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E83AB48A-F78A-4D8E-8833-DFD95946F16A",
              "versionEndExcluding": "r400.6",
              "versionStartIncluding": "r400",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "899CC094-462B-4862-97D6-DAF1BDD70B5C",
              "versionEndExcluding": "r410.6",
              "versionStartIncluding": "r410",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:honeywell:experion_process_knowledge_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19429BFB-4485-4F36-9DF9-3BD83DE3F1FD",
              "versionEndExcluding": "r430.2",
              "versionStartIncluding": "r430",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
    },
    {
      "lang": "es",
      "value": "Existen m\u00faltiples vulnerabilidades de desbordamiento de b\u00fafer basado en memoria din\u00e1mica (heap) en Honeywell Experion PKS, en todas la versiones anteriores a la R400.6, todas la versiones anteriores a la R410.6 y todas la versiones anteriores a la R430.2, lo cual podr\u00eda llevar a una posible ejecuci\u00f3n remota de c\u00f3digo o denegaci\u00f3n de servicio (DoS). Honeywell recomienda encarecidamente que todos los usuarios que ejecuten versiones sin soporte de EKPS anteriores a la R400 actualicen el producto a una versi\u00f3n soportada."
    }
  ],
  "id": "CVE-2014-9187",
  "lastModified": "2024-11-21T02:20:21.880",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-03-25T20:29:00.253",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}