Vulnerabilites related to yokogawa - fcn-500
Vulnerability from fkie_nvd
Published
2018-10-12 14:29
Modified
2024-11-21 03:55
Severity ?
Summary
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
yokogawa | fcj_firmware | * | |
yokogawa | fcj | - | |
yokogawa | fcn-100_firmware | * | |
yokogawa | fcn-100 | - | |
yokogawa | fcn-rtu_firmware | * | |
yokogawa | fcn-rtu | - | |
yokogawa | fcn-500_firmware | * | |
yokogawa | fcn-500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcj_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD8D4A48-1191-4E3E-9FBF-283F74A2DAF0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcj:-:*:*:*:*:*:*:*", "matchCriteriaId": "B69DBB88-A5E6-42BA-A7C1-2ADA8CF5349C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D532D5-B79A-445E-8201-0B83847AB408", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB180CFC-1A4F-4DE9-8A3A-A6F50DDDC892", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-rtu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EBF679A-7825-408A-B336-A0CAE5996FA0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-rtu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E636BC2D-506C-4D8D-BD8B-D02776AD3890", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50B80091-CCE3-4303-A0CE-730719AC9178", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-500:-:*:*:*:*:*:*:*", "matchCriteriaId": "500FFA96-0861-4EBC-8768-68A4D4C6ECB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work." }, { "lang": "es", "value": "En Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, en todas las versiones R4.10 y anteriores, los controladores afectados emplean credenciales embebidas que podr\u00edan permitir que un atacante obtenga acceso no autorizado a las funciones de mantenimiento y obtenga o modifique informaci\u00f3n. El ataque solo se puede ejecutar durante los trabajos de mantenimiento." } ], "id": "CVE-2018-17896", "lastModified": "2024-11-21T03:55:09.643", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-12T14:29:00.847", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-12 14:29
Modified
2024-11-21 03:55
Severity ?
Summary
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
yokogawa | fcj_firmware | * | |
yokogawa | fcj | - | |
yokogawa | fcn-100_firmware | * | |
yokogawa | fcn-100 | - | |
yokogawa | fcn-rtu_firmware | * | |
yokogawa | fcn-rtu | - | |
yokogawa | fcn-500_firmware | * | |
yokogawa | fcn-500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcj_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD8D4A48-1191-4E3E-9FBF-283F74A2DAF0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcj:-:*:*:*:*:*:*:*", "matchCriteriaId": "B69DBB88-A5E6-42BA-A7C1-2ADA8CF5349C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D532D5-B79A-445E-8201-0B83847AB408", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB180CFC-1A4F-4DE9-8A3A-A6F50DDDC892", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-rtu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EBF679A-7825-408A-B336-A0CAE5996FA0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-rtu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E636BC2D-506C-4D8D-BD8B-D02776AD3890", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50B80091-CCE3-4303-A0CE-730719AC9178", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-500:-:*:*:*:*:*:*:*", "matchCriteriaId": "500FFA96-0861-4EBC-8768-68A4D4C6ECB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers." }, { "lang": "es", "value": "En Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, en todas las versiones R4.10 y anteriores, la aplicaci\u00f3n web protege incorrectamente las credenciales, lo que podr\u00eda permitir que un atacante obtenga credenciales para acceder remotamente a los controladores." } ], "id": "CVE-2018-17900", "lastModified": "2024-11-21T03:55:10.177", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-12T14:29:01.207", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-07-31 17:29
Modified
2024-11-21 03:41
Severity ?
Summary
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/104376 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/104376 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
yokogawa | fcj_firmware | * | |
yokogawa | fcj | - | |
yokogawa | fcn-100_firmware | * | |
yokogawa | fcn-100 | - | |
yokogawa | fcn-rtu_firmware | * | |
yokogawa | fcn-rtu | - | |
yokogawa | fcn-500_firmware | * | |
yokogawa | fcn-500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcj_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFEF0D4A-1FAD-4935-BB42-2120EEEEA205", "versionEndIncluding": "r4.02", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcj:-:*:*:*:*:*:*:*", "matchCriteriaId": "B69DBB88-A5E6-42BA-A7C1-2ADA8CF5349C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA797459-D1AD-4BD6-9F9B-EECFC2548E31", "versionEndIncluding": "r4.02", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB180CFC-1A4F-4DE9-8A3A-A6F50DDDC892", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-rtu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "301CCAA4-3B78-4074-887F-BD9571FB0171", "versionEndIncluding": "r4.02", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-rtu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E636BC2D-506C-4D8D-BD8B-D02776AD3890", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5EB434F5-A970-497E-B5B2-207B9FC6AAAE", "versionEndIncluding": "r4.02", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-500:-:*:*:*:*:*:*:*", "matchCriteriaId": "500FFA96-0861-4EBC-8768-68A4D4C6ECB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution." }, { "lang": "es", "value": "Los controladores Yokogawa STARDOM FCJ R4.02 y anteriores, FCN-100 R4.02 y anteriores, FCN-RTU R4.02 y anteriores y FCN-500 y anteriores R4.02 emplean credenciales embebidas que podr\u00edan permitir que un atacante obtenga acceso administrativo no autorizado al dispositivo, lo que podr\u00eda resultar en la ejecuci\u00f3n remota de c\u00f3digo." } ], "id": "CVE-2018-10592", "lastModified": "2024-11-21T03:41:37.347", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-07-31T17:29:00.233", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/104376" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/104376" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-12 14:29
Modified
2024-11-21 03:55
Severity ?
Summary
Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
yokogawa | fcj_firmware | * | |
yokogawa | fcj | - | |
yokogawa | fcn-100_firmware | * | |
yokogawa | fcn-100 | - | |
yokogawa | fcn-rtu_firmware | * | |
yokogawa | fcn-rtu | - | |
yokogawa | fcn-500_firmware | * | |
yokogawa | fcn-500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcj_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD8D4A48-1191-4E3E-9FBF-283F74A2DAF0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcj:-:*:*:*:*:*:*:*", "matchCriteriaId": "B69DBB88-A5E6-42BA-A7C1-2ADA8CF5349C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D532D5-B79A-445E-8201-0B83847AB408", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB180CFC-1A4F-4DE9-8A3A-A6F50DDDC892", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-rtu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EBF679A-7825-408A-B336-A0CAE5996FA0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-rtu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E636BC2D-506C-4D8D-BD8B-D02776AD3890", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50B80091-CCE3-4303-A0CE-730719AC9178", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-500:-:*:*:*:*:*:*:*", "matchCriteriaId": "500FFA96-0861-4EBC-8768-68A4D4C6ECB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable." }, { "lang": "es", "value": "En Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, en todas las versiones R4.10 y anteriores, la aplicaci\u00f3n del controlador no evita el agotamiento de memoria debido a peticiones no autorizadas. Esto podr\u00eda permitir que el atacante provoque que el controlador se vuelva inestable." } ], "id": "CVE-2018-17898", "lastModified": "2024-11-21T03:55:09.900", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-12T14:29:01.033", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-12 14:29
Modified
2024-11-21 03:55
Severity ?
Summary
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
yokogawa | fcj_firmware | * | |
yokogawa | fcj | - | |
yokogawa | fcn-100_firmware | * | |
yokogawa | fcn-100 | - | |
yokogawa | fcn-rtu_firmware | * | |
yokogawa | fcn-rtu | - | |
yokogawa | fcn-500_firmware | * | |
yokogawa | fcn-500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcj_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DD8D4A48-1191-4E3E-9FBF-283F74A2DAF0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcj:-:*:*:*:*:*:*:*", "matchCriteriaId": "B69DBB88-A5E6-42BA-A7C1-2ADA8CF5349C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96D532D5-B79A-445E-8201-0B83847AB408", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB180CFC-1A4F-4DE9-8A3A-A6F50DDDC892", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-rtu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EBF679A-7825-408A-B336-A0CAE5996FA0", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-rtu:-:*:*:*:*:*:*:*", "matchCriteriaId": "E636BC2D-506C-4D8D-BD8B-D02776AD3890", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:yokogawa:fcn-500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50B80091-CCE3-4303-A0CE-730719AC9178", "versionEndIncluding": "r4.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:yokogawa:fcn-500:-:*:*:*:*:*:*:*", "matchCriteriaId": "500FFA96-0861-4EBC-8768-68A4D4C6ECB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions." }, { "lang": "es", "value": "En Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, en todas las versiones R4.10 y anteriores, la aplicaci\u00f3n emplea m\u00faltiples m\u00e9todos de gesti\u00f3n de sesiones, lo que podr\u00eda resultar en una denegaci\u00f3n de servicio (DoS) de las funciones de gesti\u00f3n remota." } ], "id": "CVE-2018-17902", "lastModified": "2024-11-21T03:55:10.433", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-12T14:29:01.423", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-384" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-384" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2018-10592 (GCVE-0-2018-10592)
Vulnerability from cvelistv5
Published
2018-07-31 17:00
Modified
2024-09-16 17:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - USE OF HARD-CODED CREDENTIALS
Summary
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Yokogawa | STARDOM FCJ Controllers |
Version: R4.02 and prior |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T07:39:08.364Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf" }, { "name": "104376", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104376" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "STARDOM FCJ Controllers", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "R4.02 and prior" } ] }, { "product": "STARDOM FCN-100 Controllers", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "R4.02 and prior" } ] }, { "product": "STARDOM FCN-RTU Controllers", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "R4.02 and prior" } ] }, { "product": "STARDOM FCN-500 Controllers", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "R4.02 and prior" } ] } ], "datePublic": "2018-05-31T00:00:00", "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "USE OF HARD-CODED CREDENTIALS CWE-798", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-08-01T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf" }, { "name": "104376", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104376" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-05-31T00:00:00", "ID": "CVE-2018-10592", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "STARDOM FCJ Controllers", "version": { "version_data": [ { "version_value": "R4.02 and prior" } ] } }, { "product_name": "STARDOM FCN-100 Controllers", "version": { "version_data": [ { "version_value": "R4.02 and prior" } ] } }, { "product_name": "STARDOM FCN-RTU Controllers", "version": { "version_data": [ { "version_value": "R4.02 and prior" } ] } }, { "product_name": "STARDOM FCN-500 Controllers", "version": { "version_data": [ { "version_value": "R4.02 and prior" } ] } } ] }, "vendor_name": "Yokogawa" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "USE OF HARD-CODED CREDENTIALS CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf", "refsource": "CONFIRM", "url": "https://web-material3.yokogawa.com/1/6712/details/YSAR-18-0004-E.pdf" }, { "name": "104376", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104376" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-10592", "datePublished": "2018-07-31T17:00:00Z", "dateReserved": "2018-05-01T00:00:00", "dateUpdated": "2024-09-16T17:38:31.810Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-17900 (GCVE-0-2018-17900)
Vulnerability from cvelistv5
Published
2018-10-12 14:00
Modified
2024-09-16 19:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-522 - INSUFFICIENTLY PROTECTED CREDENTIALS
Summary
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Yokogawa | STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500 |
Version: All versions R4.10 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:01:14.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "All versions R4.10 and prior" } ] } ], "datePublic": "2018-09-28T00:00:00", "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-12T13:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-28T00:00:00", "ID": "CVE-2018-17900", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "version": { "version_data": [ { "version_value": "All versions R4.10 and prior" } ] } } ] }, "vendor_name": "Yokogawa" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522" } ] } ] }, "references": { "reference_data": [ { "name": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf", "refsource": "CONFIRM", "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-17900", "datePublished": "2018-10-12T14:00:00Z", "dateReserved": "2018-10-02T00:00:00", "dateUpdated": "2024-09-16T19:37:05.913Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-17896 (GCVE-0-2018-17896)
Vulnerability from cvelistv5
Published
2018-10-12 14:00
Modified
2024-09-17 00:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - USE OF HARD-CODED CREDENTIALS
Summary
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Yokogawa | STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500 |
Version: All versions prior to version X.X |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:01:14.599Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "All versions prior to version X.X" } ] } ], "datePublic": "2018-09-28T00:00:00", "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "USE OF HARD-CODED CREDENTIALS CWE-798", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-12T13:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-28T00:00:00", "ID": "CVE-2018-17896", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "version": { "version_data": [ { "version_value": "All versions prior to version X.X" } ] } } ] }, "vendor_name": "Yokogawa" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The affected controllers utilize hard-coded credentials which may allow an attacker gain unauthorized access to the maintenance functions and obtain or modify information. This attack can be executed only during maintenance work." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "USE OF HARD-CODED CREDENTIALS CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf", "refsource": "CONFIRM", "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-17896", "datePublished": "2018-10-12T14:00:00Z", "dateReserved": "2018-10-02T00:00:00", "dateUpdated": "2024-09-17T00:26:50.260Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-17898 (GCVE-0-2018-17898)
Vulnerability from cvelistv5
Published
2018-10-12 14:00
Modified
2024-09-17 01:01
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION')
Summary
Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Yokogawa | STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500 |
Version: All versions R4.10 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:01:14.517Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "All versions R4.10 and prior" } ] } ], "datePublic": "2018-09-28T00:00:00", "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-12T13:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-28T00:00:00", "ID": "CVE-2018-17898", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "version": { "version_data": [ { "version_value": "All versions R4.10 and prior" } ] } } ] }, "vendor_name": "Yokogawa" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Yokogawa STARDOM Controllers FCJ,FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The controller application fails to prevent memory exhaustion by unauthorized requests. This could allow an attacker to cause the controller to become unstable." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400" } ] } ] }, "references": { "reference_data": [ { "name": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf", "refsource": "CONFIRM", "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-17898", "datePublished": "2018-10-12T14:00:00Z", "dateReserved": "2018-10-02T00:00:00", "dateUpdated": "2024-09-17T01:01:51.691Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-17902 (GCVE-0-2018-17902)
Vulnerability from cvelistv5
Published
2018-10-12 14:00
Modified
2024-09-16 18:34
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-384 - SESSION FIXATION
Summary
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Yokogawa | STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500 |
Version: All versions R4.10 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:01:14.694Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "vendor": "Yokogawa", "versions": [ { "status": "affected", "version": "All versions R4.10 and prior" } ] } ], "datePublic": "2018-09-28T00:00:00", "descriptions": [ { "lang": "en", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-384", "description": "SESSION FIXATION CWE-384", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-12T13:57:02", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-28T00:00:00", "ID": "CVE-2018-17902", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "STARDOM Controllers FCJ,FCN-100,FCN-RTU, FCN-500", "version": { "version_data": [ { "version_value": "All versions R4.10 and prior" } ] } } ] }, "vendor_name": "Yokogawa" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "SESSION FIXATION CWE-384" } ] } ] }, "references": { "reference_data": [ { "name": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf", "refsource": "CONFIRM", "url": "https://web-material3.yokogawa.com/YSAR-18-0007-E.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-17902", "datePublished": "2018-10-12T14:00:00Z", "dateReserved": "2018-10-02T00:00:00", "dateUpdated": "2024-09-16T18:34:00.672Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }