Vulnerabilites related to innominate - mguard_industrial_rs_bd-501020
Vulnerability from fkie_nvd
Published
2012-06-19 18:55
Modified
2025-04-11 00:51
Severity ?
Summary
The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf | Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf | Broken Link, Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs | Not Applicable | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf | Broken Link, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs | Not Applicable |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:innominate:mguard_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1137F55-09EF-4F7C-8EFF-923B6C8CBA75", "versionEndExcluding": "7.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:innominate:eagle_mguard_bd-301010:-:*:*:*:*:*:*:*", "matchCriteriaId": "39221D0D-E26E-4477-9CC7-C7DD8E3991FF", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:eagle_mguard_hw-201000:-:*:*:*:*:*:*:*", "matchCriteriaId": "7B31DD61-EB19-449E-9800-3FE35ABCB923", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_blade_hw-104020:-:*:*:*:*:*:*:*", "matchCriteriaId": "E79CDFEB-98E1-42E1-8F71-D15B6F439135", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_blade_hw-104050:-:*:*:*:*:*:*:*", "matchCriteriaId": "275E8504-9771-4CAA-859C-AE1CF83C0AAC", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_delta_bd-201000:-:*:*:*:*:*:*:*", "matchCriteriaId": "DBC67D72-51CF-4B76-A439-0135B0494412", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_delta_hw-103050:-:*:*:*:*:*:*:*", "matchCriteriaId": "2EC89F6F-A767-4C38-A2E3-8927E8B43A40", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_industrial_rs_bd-501000:-:*:*:*:*:*:*:*", "matchCriteriaId": "A7D78EF2-A75A-4F47-8907-CDF4091F6E1B", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_industrial_rs_bd-501010:-:*:*:*:*:*:*:*", "matchCriteriaId": "86C7033A-ECFA-4487-AF65-E0B787312F43", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_industrial_rs_bd-501020:-:*:*:*:*:*:*:*", "matchCriteriaId": "E2DD96F8-6BF2-44B8-B458-22B34A2C7C49", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_industrial_rs_hw-105000:-:*:*:*:*:*:*:*", "matchCriteriaId": "7DCD2CCC-FA85-42AA-931A-23DE15319BD0", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_pci_bd-111010:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B19092E-9542-45D2-8323-FCB2F08A7CDD", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_pci_bd-111020:-:*:*:*:*:*:*:*", "matchCriteriaId": "C66EA5A6-B1E4-45F1-B60F-73C6D7CC2011", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_pci_hw-102020:-:*:*:*:*:*:*:*", "matchCriteriaId": "ED522AD4-21E5-44C7-BE73-92318D84A59F", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_pci_hw-102050:-:*:*:*:*:*:*:*", "matchCriteriaId": "366A012C-905C-4523-AE75-2864C329693C", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_smart_bd-101010:-:*:*:*:*:*:*:*", "matchCriteriaId": "B23C8DDF-74C1-41EC-961F-C8D2759087C4", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_smart_bd-101020:-:*:*:*:*:*:*:*", "matchCriteriaId": "AC7B1E51-6FBB-4EA4-9170-D862648D112D", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_smart_hw-101020:-:*:*:*:*:*:*:*", "matchCriteriaId": "94736549-BC05-4336-A800-4E11628BDFDB", "vulnerable": false }, { "criteria": "cpe:2.3:h:innominate:mguard_smart_hw-101050:-:*:*:*:*:*:*:*", "matchCriteriaId": "99114202-2EC3-4DDB-9ABF-F36A841CCF39", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value." }, { "lang": "es", "value": "The Innominate mGuard Smart HW antes de HW-101130 y BD antes de BD-101030, mGuard industrial RS, mGuard delta HW antes de HW-103060 y BD antes de BD-211010, mGuard PCI, mGuard blade, y EAGLE mGuard con sistema anterior a v7.5.0, no utiliza una fuente suficiente de la entrop\u00eda de las claves privadas, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes de MITM (man-in-the-middle) falsificar (1) HTTPS o (2) servidores SSH mediante la predicci\u00f3n de un valor clave." } ], "id": "CVE-2012-3006", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "HIGH", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:H/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2012-06-19T18:55:01.113", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Third Party Advisory", "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Not Applicable" ], "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory", "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-310" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2012-3006 (GCVE-0-2012-3006)
Vulnerability from cvelistv5
Published
2012-06-19 18:00
Modified
2024-09-16 23:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.421Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2012-06-19T18:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3006", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs", "refsource": "MISC", "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs" }, { "name": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf", "refsource": "CONFIRM", "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3006", "datePublished": "2012-06-19T18:00:00Z", "dateReserved": "2012-05-30T00:00:00Z", "dateUpdated": "2024-09-16T23:11:27.552Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }