CVE-2012-3006 (GCVE-0-2012-3006)
Vulnerability from cvelistv5
Published
2012-06-19 18:00
Modified
2024-09-16 23:11
Severity ?
CWE
  • n/a
Summary
The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:50:05.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-06-19T18:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-3006",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs",
              "refsource": "MISC",
              "url": "https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs"
            },
            {
              "name": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-3006",
    "datePublished": "2012-06-19T18:00:00Z",
    "dateReserved": "2012-05-30T00:00:00Z",
    "dateUpdated": "2024-09-16T23:11:27.552Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2012-3006\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2012-06-19T18:55:01.113\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Innominate mGuard Smart HW before HW-101130 and BD before BD-101030, mGuard industrial RS, mGuard delta HW before HW-103060 and BD before BD-211010, mGuard PCI, mGuard blade, and EAGLE mGuard appliances with software before 7.5.0 do not use a sufficient source of entropy for private keys, which makes it easier for man-in-the-middle attackers to spoof (1) HTTPS or (2) SSH servers by predicting a key value.\"},{\"lang\":\"es\",\"value\":\"The Innominate mGuard Smart HW antes de HW-101130 y BD antes de BD-101030, mGuard industrial RS, mGuard delta HW antes de HW-103060 y BD antes de BD-211010, mGuard PCI, mGuard blade, y EAGLE mGuard con sistema anterior a v7.5.0, no utiliza una fuente suficiente de la entrop\u00eda de las claves privadas, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes de MITM (man-in-the-middle) falsificar (1) HTTPS o (2) servidores SSH mediante la predicci\u00f3n de un valor clave.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:H/Au:S/C:C/I:C/A:C\",\"baseScore\":7.1,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"HIGH\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-310\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:innominate:mguard_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.5.0\",\"matchCriteriaId\":\"C1137F55-09EF-4F7C-8EFF-923B6C8CBA75\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:eagle_mguard_bd-301010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39221D0D-E26E-4477-9CC7-C7DD8E3991FF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:eagle_mguard_hw-201000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B31DD61-EB19-449E-9800-3FE35ABCB923\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_blade_hw-104020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E79CDFEB-98E1-42E1-8F71-D15B6F439135\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_blade_hw-104050:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"275E8504-9771-4CAA-859C-AE1CF83C0AAC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_delta_bd-201000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DBC67D72-51CF-4B76-A439-0135B0494412\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_delta_hw-103050:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2EC89F6F-A767-4C38-A2E3-8927E8B43A40\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_industrial_rs_bd-501000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A7D78EF2-A75A-4F47-8907-CDF4091F6E1B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_industrial_rs_bd-501010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"86C7033A-ECFA-4487-AF65-E0B787312F43\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_industrial_rs_bd-501020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E2DD96F8-6BF2-44B8-B458-22B34A2C7C49\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_industrial_rs_hw-105000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7DCD2CCC-FA85-42AA-931A-23DE15319BD0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_pci_bd-111010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B19092E-9542-45D2-8323-FCB2F08A7CDD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_pci_bd-111020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C66EA5A6-B1E4-45F1-B60F-73C6D7CC2011\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_pci_hw-102020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ED522AD4-21E5-44C7-BE73-92318D84A59F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_pci_hw-102050:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"366A012C-905C-4523-AE75-2864C329693C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_smart_bd-101010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B23C8DDF-74C1-41EC-961F-C8D2759087C4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_smart_bd-101020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC7B1E51-6FBB-4EA4-9170-D862648D112D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_smart_hw-101020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94736549-BC05-4336-A800-4E11628BDFDB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:innominate:mguard_smart_hw-101050:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99114202-2EC3-4DDB-9ABF-F36A841CCF39\"}]}]}],\"references\":[{\"url\":\"http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Not Applicable\"]},{\"url\":\"http://www.innominate.com/data/downloads/software/innominate_security_advisory_20120614_001.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-167-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://freedom-to-tinker.com/blog/nadiah/new-research-theres-no-need-panic-over-factorable-keys-just-mind-your-ps-and-qs\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Not Applicable\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…