Vulnerabilites related to phoenixcontact - plcnext_engineer
CVE-2020-12499 (GCVE-0-2020-12499)
Vulnerability from cvelistv5
Published
2020-07-21 15:09
Modified
2024-09-17 03:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
PHOENIX CONTACT | PLCnext Engineer |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.067Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-025" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PLCnext Engineer", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2020.3.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "This vulnerability was discovered and reported by Amir Preminger of Claroty." }, { "lang": "en", "value": "PHOENIX CONTACT reported the vulnerability to CERT@VDE." } ], "datePublic": "2020-07-21T00:00:00", "descriptions": [ { "lang": "en", "value": "In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-21T15:09:40", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-025" } ], "solutions": [ { "lang": "en", "value": "Temporary Fix / Mitigation: We strongly recommend customers to exchange project files only using secure file exchange\nservices. Project files should not be exchanged via unencrypted email. Users should avoid\nimporting project files from unknown source and exchange or store project files together with a\nchecksum to ensure their integrity." }, { "lang": "en", "value": "Remediation: Phoenix Contact strongly recommends updating to the latest version PLCnext Enineer 2020.6 or\nhigher, which fixes this vulnerability." } ], "source": { "advisory": "VDE-2020-025", "discovery": "UNKNOWN" }, "title": "PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier: Improper path sanitation vulnerability.", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2020-07-21T09:44:00.000Z", "ID": "CVE-2020-12499", "STATE": "PUBLIC", "TITLE": "PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier: Improper path sanitation vulnerability." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PLCnext Engineer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "2020.3.1" } ] } } ] }, "vendor_name": "PHOENIX CONTACT" } ] } }, "credit": [ { "lang": "eng", "value": "This vulnerability was discovered and reported by Amir Preminger of Claroty." }, { "lang": "eng", "value": "PHOENIX CONTACT reported the vulnerability to CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en-us/advisories/vde-2020-025", "refsource": "MISC", "url": "https://cert.vde.com/en-us/advisories/vde-2020-025" } ] }, "solution": [ { "lang": "en", "value": "Temporary Fix / Mitigation: We strongly recommend customers to exchange project files only using secure file exchange\nservices. Project files should not be exchanged via unencrypted email. Users should avoid\nimporting project files from unknown source and exchange or store project files together with a\nchecksum to ensure their integrity." }, { "lang": "en", "value": "Remediation: Phoenix Contact strongly recommends updating to the latest version PLCnext Enineer 2020.6 or\nhigher, which fixes this vulnerability." } ], "source": { "advisory": "VDE-2020-025", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12499", "datePublished": "2020-07-21T15:09:40.065169Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-17T03:18:07.103Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-3935 (GCVE-0-2023-3935)
Vulnerability from cvelistv5
Published
2023-09-13 13:19
Modified
2025-05-01 03:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-787 - Out-of-bounds Write
Summary
A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
► | Wibu | CodeMeter Runtime |
Version: 0.0 < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:08:50.775Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-031/" }, { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-030/" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-3935", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "" } ], "role": "CISA Coordinator", "timestamp": "2024-07-19T00:00:00+00:00", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-05-01T03:55:09.776Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CodeMeter Runtime", "vendor": "Wibu", "versions": [ { "lessThanOrEqual": "7.60b", "status": "affected", "version": "0.0", "versionType": "custom" } ] }, { "defaultStatus": "affected", "product": "CodeMeter Runtime", "vendor": "Wibu", "versions": [ { "status": "unaffected", "version": "7.21g" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system." } ], "value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-09-19T07:00:20.911Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf" }, { "url": "https://cert.vde.com/en/advisories/VDE-2023-031/" }, { "url": "https://cert.vde.com/en/advisories/VDE-2023-030/" } ], "source": { "defect": [ "CERT@VDE#64566" ], "discovery": "UNKNOWN" }, "title": "Wibu: Buffer Overflow in CodeMeter Runtime", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2023-3935", "datePublished": "2023-09-13T13:19:18.392Z", "dateReserved": "2023-07-25T13:02:40.206Z", "dateUpdated": "2025-05-01T03:55:09.776Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from cvelistv5
Published
2023-12-14 14:05
Modified
2024-08-02 20:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | PHOENIX CONTACT | AXC F 1152 |
Version: 0 ≤ 2024.0 |
|||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.840Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AXC F 1152", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "AXC F 2152", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "AXC F 3152", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "BPC 9102S", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "EPC 1502", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "EPC 1522", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PLCnext Engineer", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "RFC 4072R", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "RFC 4072S", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Reid Wightman of Dragos, Inc." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices." } ], "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-14T14:05:35.741Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "source": { "advisory": "VDE-2023-056", "defect": [ "CERT@VDE#64609" ], "discovery": "EXTERNAL" }, "title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2023-46142", "datePublished": "2023-12-14T14:05:35.741Z", "dateReserved": "2023-10-17T07:04:03.576Z", "dateUpdated": "2024-08-02T20:37:39.840Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from cvelistv5
Published
2023-12-14 14:08
Modified
2024-10-01 06:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-494 - Download of Code Without Integrity Check
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | PHOENIX CONTACT | AXC F 1152 |
Version: 0 ≤ 2024.0 |
|||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.934Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "AXC F 1152", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "AXC F 2152", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "AXC F 3152", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "BPC 9102S", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "EPC 1502", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "EPC 1522", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PLCnext Engineer", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "RFC 4072R", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "RFC 4072S", "vendor": "PHOENIX CONTACT", "versions": [ { "lessThanOrEqual": "2024.0", "status": "affected", "version": "0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Reid Wightman of Dragos, Inc." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices." } ], "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-494", "description": "CWE-494: Download of Code Without Integrity Check", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-01T06:18:18.730Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "source": { "advisory": "VDE-2023-058", "defect": [ "CERT@VDE#64611" ], "discovery": "EXTERNAL" }, "title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2023-46144", "datePublished": "2023-12-14T14:08:07.244Z", "dateReserved": "2023-10-17T07:04:03.577Z", "dateUpdated": "2024-10-01T06:18:18.730Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2020-07-21 15:15
Modified
2024-11-21 04:59
Severity ?
8.2 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Summary
In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files.
References
▶ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://cert.vde.com/en-us/advisories/vde-2020-025 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en-us/advisories/vde-2020-025 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
phoenixcontact | plcnext_engineer | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3C43096-BEA2-41C9-83CF-F4BFAFFE8BE5", "versionEndIncluding": "2020-3-1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In PHOENIX CONTACT PLCnext Engineer version 2020.3.1 and earlier an improper path sanitation vulnerability exists on import of project files." }, { "lang": "es", "value": "En PHOENIX CONTACT PLCnext Engineer versi\u00f3n 2020.3.1 y anteriores, presenta una vulnerabilidad de saneamiento de ruta inapropiada en la importaci\u00f3n de archivos de proyecto" } ], "id": "CVE-2020-12499", "lastModified": "2024-11-21T04:59:48.513", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.4, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "info@cert.vde.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-21T15:15:13.677", "references": [ { "source": "info@cert.vde.com", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-025" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-025" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "info@cert.vde.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-09-13 14:15
Modified
2024-11-21 08:18
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:wibu:codemeter_runtime:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F783582-7E13-457E-96E9-8FD2D58580F5", "versionEndExcluding": "7.60c", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:trumpf:oseon:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BCF0613-5F59-4DAA-9DDB-A9322892353A", "versionEndIncluding": "3.0.22", "versionStartIncluding": "1.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:programmingtube:*:*:*:*:*:*:*:*", "matchCriteriaId": "9648C643-3213-4D0B-A3E0-6C4A092E8DAE", "versionEndIncluding": "4.6.3", "versionStartIncluding": "1.0.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:teczonebend:*:*:*:*:*:*:*:*", "matchCriteriaId": "56F0DB5E-5F18-4DA4-9488-242351FE5994", "versionEndIncluding": "23.06.01", "versionStartIncluding": "18.02.r8", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:tops_unfold:05.03.00.00:*:*:*:*:*:*:*", "matchCriteriaId": "926A92BB-2001-4176-9F73-F7F40F4D58CE", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:topscalculation:*:*:*:*:*:*:*:*", "matchCriteriaId": "903A6767-5E6D-4E98-A756-A3FC99BAF13F", "versionEndIncluding": "22.00.00", "versionStartIncluding": "14.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trumpflicenseexpert:*:*:*:*:*:*:*:*", "matchCriteriaId": "54F8DF4D-3C69-4117-88A4-9C0F6838C7DD", "versionEndIncluding": "1.11.1", "versionStartIncluding": "1.5.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutops:*:*:*:*:*:*:*:*", "matchCriteriaId": "8360F8C5-1F88-420F-91B2-C75EC8A97A0C", "versionEndIncluding": "12.01.00.00", "versionStartIncluding": "08.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutops_cell_classic:*:*:*:*:*:*:*:*", "matchCriteriaId": "3240055F-E26E-4BE9-89A9-D50A6FA5E8F1", "versionEndIncluding": "09.09.02", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutops_cell_sw48:*:*:*:*:*:*:*:*", "matchCriteriaId": "7CD0343C-7A91-4CF7-B70B-CB2569FFE679", "versionEndIncluding": "02.26.0", "versionStartIncluding": "01.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutops_mark_3d:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB6D30E6-031C-4104-A573-2FD3773E1CDF", "versionEndIncluding": "06.01", "versionStartIncluding": "01.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutopsboost:*:*:*:*:*:*:*:*", "matchCriteriaId": "B55ED3C4-B111-4A8C-BB9F-A50FCCC38432", "versionEndIncluding": "16.0.22", "versionStartIncluding": "06.00.23.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutopsfab:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4180D87-1915-4868-9328-D310282DD7C4", "versionEndIncluding": "22.8.25", "versionStartIncluding": "15.00.23.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutopsfab_storage_smallstore:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C7823FE-A87C-494B-AB35-AB2830884282", "versionEndIncluding": "20.04.20.00", "versionStartIncluding": "14.06.20", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutopsprint:*:*:*:*:*:*:*:*", "matchCriteriaId": "A257AA96-76DA-47CC-A3BA-3CCFB719C62E", "versionEndIncluding": "01.00", "versionStartIncluding": "00.06.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutopsprintmultilaserassistant:*:*:*:*:*:*:*:*", "matchCriteriaId": "607CE0A6-C1CB-4B30-A7C7-FFEDF8DB0DA1", "versionStartIncluding": "01.02", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:trutopsweld:*:*:*:*:*:*:*:*", "matchCriteriaId": "1561DCB8-AEAF-45A8-9F6F-EEB6A49452C9", "versionEndIncluding": "9.0.28148.1", "versionStartIncluding": "7.0.198.241", "vulnerable": true }, { "criteria": "cpe:2.3:a:trumpf:tubedesign:*:*:*:*:*:*:*:*", "matchCriteriaId": "D88C313D-95E2-44EA-A895-F4CA659A5846", "versionEndIncluding": "14.06.150", "versionStartIncluding": "08.00", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:phoenixcontact:activation_wizard:*:*:*:*:*:moryx:*:*", "matchCriteriaId": "E8198A71-1EA7-4DAC-8D4F-EB646A0DC635", "versionEndIncluding": "1.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:phoenixcontact:e-mobility_charging_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B2B109F-41E0-4CC9-9F9F-F1AD06E1EA77", "versionEndIncluding": "1.7.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:phoenixcontact:fl_network_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "C8751F63-3D03-434A-BF4E-67320F6672FD", "versionEndIncluding": "7.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:phoenixcontact:iol-conf:*:*:*:*:*:*:*:*", "matchCriteriaId": "907E5EB3-8346-4371-9CFF-0F885CC0529E", "versionEndIncluding": "1.7.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:phoenixcontact:module_type_package_designer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9659319-4AEC-4112-9EAC-7892C0A37AA8", "versionEndExcluding": "1.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:phoenixcontact:module_type_package_designer:1.2.0:beta:*:*:*:*:*:*", "matchCriteriaId": "BB44DD6D-7685-4346-91BC-30CB9531982A", "vulnerable": true }, { "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*", "matchCriteriaId": "170FABD2-23D5-4885-AA09-B4130F945564", "versionEndIncluding": "2023.6", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system." }, { "lang": "es", "value": "Una vulnerabilidad de Desbordamiento del B\u00fafer en el servicio de red Wibu CodeMeter Runtime hasta la versi\u00f3n 7.60b permite a un atacante remoto no autenticado lograr RCE y obtener acceso completo al sistema anfitri\u00f3n." } ], "id": "CVE-2023-3935", "lastModified": "2024-11-21T08:18:21.260", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "info@cert.vde.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-09-13T14:15:09.147", "references": [ { "source": "info@cert.vde.com", "tags": [ "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf" }, { "source": "info@cert.vde.com", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-030/" }, { "source": "info@cert.vde.com", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-031/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-030/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-031/" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "info@cert.vde.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-14 14:15
Modified
2024-11-21 08:27
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C72F7B2-43D1-43CB-B611-B57487E9AE53", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4EA16E9E-ADBB-4943-AE2D-7C49F882A809", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E28DCF3B-C26E-44BE-BCA1-0AED56326FC3", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*", "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:bpc_9102s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A97B1250-2830-4EFC-9393-DF96E129E16D", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:bpc_9102s:-:*:*:*:*:*:*:*", "matchCriteriaId": "346E85EB-8800-40C7-A7DA-EA587CF90F08", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:epc_1502_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8E7E962-9BA0-418B-8A43-541C5278C9ED", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:epc_1502:-:*:*:*:*:*:*:*", "matchCriteriaId": "85AF0A71-02C4-4CFF-A820-5C326F066024", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:epc_1522_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3671BE8-A1DE-444E-9A24-5C86E4F0BBF1", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:epc_1522:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD531B6-09DA-4B4A-AA7C-C2A54B089C67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6A5C5E9-4F2C-44BC-8B64-29D25C789643", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE1D89DD-1717-4E84-8A33-82AA29594E7D", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072r:-:*:*:*:*:*:*:*", "matchCriteriaId": "65D9C540-F273-4EA8-8FF6-95DF46B01D89", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E633B5AB-BD27-461D-8083-20CC1C768D34", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices." }, { "lang": "es", "value": "Una descarga de c\u00f3digo sin vulnerabilidad de verificaci\u00f3n de integridad en los productos PLCnext permite que un atacante remoto con privilegios bajos comprometa la integridad de la estaci\u00f3n de ingenier\u00eda afectada y los dispositivos conectados." } ], "id": "CVE-2023-46144", "lastModified": "2024-11-21T08:27:58.380", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "info@cert.vde.com", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2023-12-14T14:15:43.447", "references": [ { "source": "info@cert.vde.com", "tags": [ "Broken Link" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-494" } ], "source": "info@cert.vde.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-12-14 14:15
Modified
2024-11-21 08:27
Severity ?
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_1152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C72F7B2-43D1-43CB-B611-B57487E9AE53", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_1152:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2474BD7-C447-4E07-A628-C729E376943D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_2152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4EA16E9E-ADBB-4943-AE2D-7C49F882A809", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_2152:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE2E6118-6587-444A-A143-9C3A1E6ED4FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:axc_f_3152_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E28DCF3B-C26E-44BE-BCA1-0AED56326FC3", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:axc_f_3152:-:*:*:*:*:*:*:*", "matchCriteriaId": "57424998-4EAB-4682-BFC4-1D2A621514F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:bpc_9102s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A97B1250-2830-4EFC-9393-DF96E129E16D", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:bpc_9102s:-:*:*:*:*:*:*:*", "matchCriteriaId": "346E85EB-8800-40C7-A7DA-EA587CF90F08", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:epc_1502_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8E7E962-9BA0-418B-8A43-541C5278C9ED", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:epc_1502:-:*:*:*:*:*:*:*", "matchCriteriaId": "85AF0A71-02C4-4CFF-A820-5C326F066024", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:epc_1522_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3671BE8-A1DE-444E-9A24-5C86E4F0BBF1", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:epc_1522:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD531B6-09DA-4B4A-AA7C-C2A54B089C67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:phoenixcontact:plcnext_engineer:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6A5C5E9-4F2C-44BC-8B64-29D25C789643", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE1D89DD-1717-4E84-8A33-82AA29594E7D", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072r:-:*:*:*:*:*:*:*", "matchCriteriaId": "65D9C540-F273-4EA8-8FF6-95DF46B01D89", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:rfc_4072s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E633B5AB-BD27-461D-8083-20CC1C768D34", "versionEndIncluding": "2024.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:rfc_4072s:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BF1EAD1-7C19-4A6E-BF87-EF3F7E526BD6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices." }, { "lang": "es", "value": "Una asignaci\u00f3n de permiso incorrecta para una vulnerabilidad de recursos cr\u00edticos en los productos PLCnext permite que un atacante remoto con privilegios bajos obtenga acceso completo a los dispositivos afectados." } ], "id": "CVE-2023-46142", "lastModified": "2024-11-21T08:27:58.077", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "info@cert.vde.com", "type": "Primary" } ] }, "published": "2023-12-14T14:15:42.983", "references": [ { "source": "info@cert.vde.com", "tags": [ "Broken Link" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "info@cert.vde.com", "type": "Primary" } ] }