Vulnerabilites related to intel - server_system_m50cyp2ur312
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:44
Severity ?
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "id": "CVE-2023-22379", "lastModified": "2024-11-21T07:44:39.977", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 4.7, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:27.557", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:49
Severity ?
6.1 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:L
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "id": "CVE-2023-25175", "lastModified": "2024-11-21T07:49:15.347", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 4.7, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:31.587", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:44
Severity ?
8.2 (High) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Access of memory location after end of buffer in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Access of memory location after end of buffer in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "id": "CVE-2023-22297", "lastModified": "2024-11-21T07:44:28.717", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:26.607", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-788" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:44
Severity ?
6.0 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Integer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable denial of service via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Integer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable denial of service via local access." } ], "id": "CVE-2023-22443", "lastModified": "2024-11-21T07:44:48.817", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 4.0, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:28.600", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-680" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-190" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:55
Severity ?
6.3 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:H/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Double free in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Double free in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "id": "CVE-2023-28411", "lastModified": "2024-11-21T07:55:00.837", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 1.1, "impactScore": 4.7, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:33.343", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-415" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-415" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:49
Severity ?
8.2 (High) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Improper buffer restrictions in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper buffer restrictions in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "id": "CVE-2023-25545", "lastModified": "2024-11-21T07:49:42.220", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:32.107", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-92" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:44
Severity ?
7.9 (High) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Summary
Out of bounds write in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Out of bounds write in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "id": "CVE-2023-22442", "lastModified": "2024-11-21T07:44:48.687", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.9, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 5.8, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:28.187", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:45
Severity ?
8.2 (High) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Buffer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Buffer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "id": "CVE-2023-22661", "lastModified": "2024-11-21T07:45:09.260", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:29.207", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:47
Severity ?
6.0 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:H
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Summary
Out of bounds read in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Out of bounds read in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "id": "CVE-2023-24475", "lastModified": "2024-11-21T07:47:56.020", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.2, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:31.273", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-05-10 14:15
Modified
2024-11-21 07:50
Severity ?
6.3 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
Summary
Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63DC5770-6109-4181-A2F9-35146DFD1FDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E07ECAC5-D17C-4602-9F2A-B7AE1DFF0818", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcpac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7588C0-6232-4969-B94F-835D8DECE894", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcpac:-:*:*:*:*:*:*:*", "matchCriteriaId": "EB006675-7691-40AB-9563-86CF841B84C8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhsvac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D969D7F5-58AD-4B54-9579-0EFC0C19EFDC", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhsvac:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45DED88-F3FE-41C7-B97A-830EC2B1C757", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mhstac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2D40D8-D1D4-443F-8E0C-A787CC01B794", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mhstac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF40323A-00D7-4422-9E47-9B419BD761F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp1mhcrac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDE560-F58E-4620-90A7-6CAC4C00F9EB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp1mhcrac:-:*:*:*:*:*:*:*", "matchCriteriaId": "6474F3CF-2D17-4CCD-8A5A-7C4EB84B9EB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_d50tnp2mfalac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30221D4C-6BA7-4EC6-89FA-67F3BC68C237", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_d50tnp2mfalac:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4B9EAF1-8AF8-4A9F-A8C7-043F979C2C44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4826826-A129-4A64-AF27-5168A2FF1ED4", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur204:-:*:*:*:*:*:*:*", "matchCriteriaId": "A102CB0A-9D55-41C6-80E2-B596A0C94D03", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp1ur212_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73008132-69ED-46E7-8D6D-060DFDCC1A2D", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp1ur212:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8A3D489-D50E-4768-92A9-61949544224C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur312_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72061DFD-D850-4F75-A299-7E035E4E4416", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur312:-:*:*:*:*:*:*:*", "matchCriteriaId": "D91066F0-B4DA-450C-A0A3-F888959B2A10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:intel:server_system_m50cyp2ur208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1422D93E-6E61-45C3-BFCD-967AF06B5AAB", "versionEndExcluding": "2.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:intel:server_system_m50cyp2ur208:-:*:*:*:*:*:*:*", "matchCriteriaId": "33C4712C-CBFE-4CF3-996F-CB0922101093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "id": "CVE-2023-25776", "lastModified": "2024-11-21T07:50:10.980", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.5, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-05-10T14:15:32.490", "references": [ { "source": "secure@intel.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2023-22443 (GCVE-0-2023-22443)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- denial of service
- CWE-680 - Integer overflow
Summary
Integer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:07:06.719Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-22443", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:08.347759Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:02:05.727Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Integer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable denial of service via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "denial of service", "lang": "en" }, { "cweId": "CWE-680", "description": "Integer overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:08.741Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-22443", "datePublished": "2023-05-10T13:17:08.741Z", "dateReserved": "2023-02-01T04:00:02.602Z", "dateUpdated": "2025-01-27T18:02:05.727Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25776 (GCVE-0-2023-25776)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- information disclosure
- CWE-20 - Improper input validation
Summary
Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:32:12.256Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25776", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:19.647845Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:02:55.643Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" }, { "cweId": "CWE-20", "description": "Improper input validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:05.623Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-25776", "datePublished": "2023-05-10T13:17:05.623Z", "dateReserved": "2023-02-15T04:00:02.911Z", "dateUpdated": "2025-01-27T18:02:55.643Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-28411 (GCVE-0-2023-28411)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- information disclosure
- CWE-415 - Double free
Summary
Double free in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:38:25.267Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-28411", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:16.904215Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:02:44.772Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Double free in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" }, { "cweId": "CWE-415", "description": "Double free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:06.167Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-28411", "datePublished": "2023-05-10T13:17:06.167Z", "dateReserved": "2023-03-22T03:00:05.332Z", "dateUpdated": "2025-01-27T18:02:44.772Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-24475 (GCVE-0-2023-24475)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- information disclosure
- CWE-125 - Out-of-bounds read
Summary
Out of bounds read in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:56:04.135Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-24475", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:11.198233Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:02:21.411Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Out of bounds read in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" }, { "cweId": "CWE-125", "description": "Out-of-bounds read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:07.225Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-24475", "datePublished": "2023-05-10T13:17:07.225Z", "dateReserved": "2023-02-15T04:00:02.948Z", "dateUpdated": "2025-01-27T18:02:21.411Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25545 (GCVE-0-2023-25545)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- escalation of privilege
- CWE-92 - Improper buffer restrictions
Summary
Improper buffer restrictions in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:25:19.211Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25545", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:27:34.667368Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:03:29.847Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper buffer restrictions in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-92", "description": "Improper buffer restrictions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:04.014Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-25545", "datePublished": "2023-05-10T13:17:04.014Z", "dateReserved": "2023-02-15T04:00:03.037Z", "dateUpdated": "2025-01-27T18:03:29.847Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-22379 (GCVE-0-2023-22379)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- information disclosure
- CWE-20 - Improper input validation
Summary
Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:07:06.580Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-22379", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:22.584952Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:03:07.190Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" }, { "cweId": "CWE-20", "description": "Improper input validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:05.067Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-22379", "datePublished": "2023-05-10T13:17:05.067Z", "dateReserved": "2023-02-15T04:00:02.990Z", "dateUpdated": "2025-01-27T18:03:07.190Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-22661 (GCVE-0-2023-22661)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- escalation of privilege
- CWE-120 - Buffer overflow
Summary
Buffer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:13:49.807Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-22661", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:27:40.160374Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:03:54.580Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Buffer overflow in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-120", "description": "Buffer overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:02.969Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-22661", "datePublished": "2023-05-10T13:17:02.969Z", "dateReserved": "2023-02-15T04:00:02.854Z", "dateUpdated": "2025-01-27T18:03:54.580Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-22442 (GCVE-0-2023-22442)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- escalation of privilege
- CWE-787 - Out-of-bounds Write
Summary
Out of bounds write in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:07:06.681Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-22442", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:25.281309Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:03:18.811Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Out of bounds write in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.9, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-787", "description": "Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:04.514Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-22442", "datePublished": "2023-05-10T13:17:04.514Z", "dateReserved": "2023-02-01T04:00:02.805Z", "dateUpdated": "2025-01-27T18:03:18.811Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-22297 (GCVE-0-2023-22297)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- escalation of privilege
- CWE-788 - Access of memory location after end of buffer
Summary
Access of memory location after end of buffer in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T10:07:06.107Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-22297", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:27:37.351458Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:03:42.960Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Access of memory location after end of buffer in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-788", "description": "Access of memory location after end of buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:03.477Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-22297", "datePublished": "2023-05-10T13:17:03.477Z", "dateReserved": "2023-02-15T04:00:03.017Z", "dateUpdated": "2025-01-27T18:03:42.960Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25175 (GCVE-0-2023-25175)
Vulnerability from cvelistv5
Published
2023-05-10 13:17
Modified
2025-01-27 18:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- information disclosure
- CWE-20 - Improper input validation
Summary
Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Intel(R) Server Board BMC firmware |
Version: before version 2.90 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:35.327Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25175", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-27T17:26:14.033198Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-27T18:02:32.282Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Server Board BMC firmware", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 2.90" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper input validation in some Intel(R) Server Board BMC firmware before version 2.90 may allow a privileged user to enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" }, { "cweId": "CWE-20", "description": "Improper input validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-10T13:17:06.661Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00839.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-25175", "datePublished": "2023-05-10T13:17:06.661Z", "dateReserved": "2023-02-15T04:00:02.876Z", "dateUpdated": "2025-01-27T18:02:32.282Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }