Vulnerabilites related to siemens - simatic_cn_4100_firmware
Vulnerability from fkie_nvd
Published
2024-05-14 16:17
Modified
2025-08-20 18:09
Severity ?
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device
locally or over the network.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cn_4100_firmware | * | |
siemens | simatic_cn_4100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cn_4100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F15A56BD-441A-4E61-A7D7-EADCCF8CC81B", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cn_4100:-:*:*:*:*:*:*:*", "matchCriteriaId": "92619F5F-3679-4424-9455-3285FF1EF2F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device\r\nlocally or over the network." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC CN 4100 (todas las versiones \u0026lt; V3.0). El dispositivo afectado contiene usuarios y credenciales indocumentados. Un atacante podr\u00eda hacer un mal uso de las credenciales para comprometer el dispositivo localmente o a trav\u00e9s de la red." } ], "id": "CVE-2024-32740", "lastModified": "2025-08-20T18:09:35.933", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-05-14T16:17:11.197", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-798" } ], "source": "productcert@siemens.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-05-14 16:17
Modified
2025-08-21 12:32
Severity ?
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cn_4100 | * | |
siemens | simatic_cn_4100 | - | |
siemens | simatic_cn_4100_firmware | * | |
siemens | simatic_cn_4100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*", "matchCriteriaId": "346AE2C1-BC0B-45D7-9406-3A365103EAA0", "versionEndExcluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_cn_4100:-:*:*:*:*:*:*:*", "matchCriteriaId": "92619F5F-3679-4424-9455-3285FF1EF2F1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cn_4100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F15A56BD-441A-4E61-A7D7-EADCCF8CC81B", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cn_4100:-:*:*:*:*:*:*:*", "matchCriteriaId": "92619F5F-3679-4424-9455-3285FF1EF2F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC CN 4100 (todas las versiones \u0026lt; V3.0). El dispositivo afectado contiene una contrase\u00f1a codificada que se utiliza para el usuario privilegiado del sistema \"root\" y para el cargador de arranque \"GRUB\" de forma predeterminada. Un atacante que logra descifrar el hash de la contrase\u00f1a obtiene acceso root al dispositivo." } ], "id": "CVE-2024-32741", "lastModified": "2025-08-21T12:32:00.647", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-05-14T16:17:11.640", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-259" } ], "source": "productcert@siemens.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-05-14 16:17
Modified
2025-08-20 18:05
Severity ?
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cn_4100_firmware | * | |
siemens | simatic_cn_4100 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cn_4100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F15A56BD-441A-4E61-A7D7-EADCCF8CC81B", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cn_4100:-:*:*:*:*:*:*:*", "matchCriteriaId": "92619F5F-3679-4424-9455-3285FF1EF2F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC CN 4100 (todas las versiones \u0026lt; V3.0). El dispositivo afectado contiene un puerto USB sin restricciones. Un atacante con acceso local al dispositivo podr\u00eda hacer un mal uso del puerto para iniciar otro sistema operativo y obtener acceso completo de lectura/escritura al sistema de archivos." } ], "id": "CVE-2024-32742", "lastModified": "2025-08-20T18:05:14.210", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 7.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-05-14T16:17:12.103", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-1326" } ], "source": "productcert@siemens.com", "type": "Secondary" } ] }
CVE-2024-32740 (GCVE-0-2024-32740)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 02:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device
locally or over the network.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SIMATIC CN 4100 |
Version: 0 < V3.0 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cn_4100", "vendor": "siemens", "versions": [ { "lessThan": "3.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-32740", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-14T12:46:23.213597Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-06T17:34:09.679Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:20:35.369Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CN 4100", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device\r\nlocally or over the network." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798: Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:24:34.549Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-32740", "datePublished": "2024-05-14T10:02:47.049Z", "dateReserved": "2024-04-17T12:35:40.941Z", "dateUpdated": "2024-08-02T02:20:35.369Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32742 (GCVE-0-2024-32742)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 02:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-1326 - Missing Immutable Root of Trust in Hardware
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SIMATIC CN 4100 |
Version: 0 < V3.0 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cn_4100", "vendor": "siemens", "versions": [ { "lessThan": "3.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-32742", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-14T12:43:18.352073Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-06T17:34:34.134Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:20:35.285Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CN 4100", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1326", "description": "CWE-1326: Missing Immutable Root of Trust in Hardware", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:24:36.881Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-32742", "datePublished": "2024-05-14T10:02:49.388Z", "dateReserved": "2024-04-17T12:35:40.942Z", "dateUpdated": "2024-08-02T02:20:35.285Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32741 (GCVE-0-2024-32741)
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 02:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-259 - Use of Hard-coded Password
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SIMATIC CN 4100 |
Version: 0 < V3.0 |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cn_4100", "vendor": "siemens", "versions": [ { "lessThan": "3.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-32741", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-14T12:45:45.741161Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-06T17:34:22.017Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:20:34.965Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CN 4100", "vendor": "Siemens", "versions": [ { "lessThan": "V3.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains hard coded password which is used for the privileged system user `root` and for the boot loader `GRUB` by default . An attacker who manages to crack the password hash gains root access to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 10, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-259", "description": "CWE-259: Use of Hard-coded Password", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:24:35.739Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-32741", "datePublished": "2024-05-14T10:02:48.224Z", "dateReserved": "2024-04-17T12:35:40.942Z", "dateUpdated": "2024-08-02T02:20:34.965Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }