Vulnerabilites related to rockwellautomation - studio_5000_logix_designer
CVE-2021-22681 (GCVE-0-2021-22681)
Vulnerability from cvelistv5
Published
2021-03-03 17:59
Modified
2024-08-03 18:51
Severity ?
CWE
  • CWE-522 - Insufficiently Protected Credentials
Summary
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
References
Impacted products
Vendor Product Version
n/a Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, Logix Controllers Version: RSLogix 5000 Versions 16 through 20
Version: Studio 5000 Logix Designer: Versions 21 and later
Version: CompactLogix 1768, 1769, 5370, 5380, 5480
Version: ControlLogix 5550, 5560, 5570, 5580
Version: DriveLogix 5560, 5730, 1794-L34
Version: Compact GuardLogix 5370, 5380
Version: GuardLogix 5570, 5580
Version: SoftLogix 5800
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:06.940Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, Logix Controllers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "RSLogix 5000 Versions 16 through 20"
            },
            {
              "status": "affected",
              "version": "Studio 5000 Logix Designer: Versions 21 and later"
            },
            {
              "status": "affected",
              "version": "CompactLogix 1768, 1769, 5370, 5380, 5480"
            },
            {
              "status": "affected",
              "version": "ControlLogix 5550, 5560, 5570, 5580"
            },
            {
              "status": "affected",
              "version": "DriveLogix 5560, 5730, 1794-L34"
            },
            {
              "status": "affected",
              "version": "Compact GuardLogix 5370, 5380"
            },
            {
              "status": "affected",
              "version": "GuardLogix 5570, 5580"
            },
            {
              "status": "affected",
              "version": "SoftLogix 5800"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "Insufficiently Protected Credentials CWE-522",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-03T17:59:43",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-22681",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation Studio 5000 Logix Designer, RSLogix 5000, Logix Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "RSLogix 5000 Versions 16 through 20"
                          },
                          {
                            "version_value": "Studio 5000 Logix Designer: Versions 21 and later"
                          },
                          {
                            "version_value": "CompactLogix 1768, 1769, 5370, 5380, 5480"
                          },
                          {
                            "version_value": "ControlLogix 5550, 5560, 5570, 5580"
                          },
                          {
                            "version_value": "DriveLogix 5560, 5730, 1794-L34"
                          },
                          {
                            "version_value": "Compact GuardLogix 5370, 5380"
                          },
                          {
                            "version_value": "GuardLogix 5570, 5580"
                          },
                          {
                            "version_value": "SoftLogix 5800"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Insufficiently Protected Credentials CWE-522"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-22681",
    "datePublished": "2021-03-03T17:59:43",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-08-03T18:51:06.940Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12038 (GCVE-0-2020-12038)
Vulnerability from cvelistv5
Published
2020-05-19 21:36
Modified
2024-08-04 11:48
Severity ?
CWE
  • CWE-119 - IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.
References
Impacted products
Vendor Product Version
n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software Version: EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:58.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-19T21:36:54",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12038",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12038",
    "datePublished": "2020-05-19T21:36:54",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:58.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12034 (GCVE-0-2020-12034)
Vulnerability from cvelistv5
Published
2020-05-20 02:38
Modified
2024-08-04 11:48
Severity ?
CWE
  • CWE-89 - IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION')
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
References
Impacted products
Vendor Product Version
n/a EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software Version: EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.791Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND (\u0027SQL INJECTION\u0027) CWE-89",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-20T02:38:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12034",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EDS Subsystem: Version 28.0.1 and prior, FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND (\u0027SQL INJECTION\u0027) CWE-89"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12034",
    "datePublished": "2020-05-20T02:38:00",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:57.791Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12025 (GCVE-0-2020-12025)
Vulnerability from cvelistv5
Published
2020-07-14 12:44
Modified
2024-08-04 11:48
Severity ?
CWE
  • CWE-611 - IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE
Summary
Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program.
References
Impacted products
Vendor Product Version
n/a Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 Version: Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.991Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02"
            }
          ]
        }
      ],
      "datePublic": "2020-07-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T12:44:30",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12025",
    "datePublished": "2020-07-14T12:44:30",
    "dateReserved": "2020-04-21T00:00:00",
    "dateUpdated": "2024-08-04T11:48:57.991Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2020-07-14 13:15
Modified
2024-11-21 04:59
Summary
Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:32.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "4083E3F1-AD2E-4A0B-9B19-67D471C25FC6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:32.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "53B85CCF-1DD1-4073-9374-F32463416C70",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:32.02:*:*:*:*:*:*:*",
              "matchCriteriaId": "16E1A28F-F6F7-4B6B-B0B6-7A3085CB31E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program."
    },
    {
      "lang": "es",
      "value": "Rockwell Automation Logix Designer Studio 5000 Versiones 32.00, 32.01 y 32.02, es susceptible a una vulnerabilidad de tipo xml external entity (XXE), que puede permitir a un atacante visualizar nombres de host u otros recursos del programa"
    }
  ],
  "id": "CVE-2020-12025",
  "lastModified": "2024-11-21T04:59:08.237",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-07-14T13:15:11.343",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-05-19 22:15
Modified
2024-11-21 04:59
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.
References
ics-cert@hq.dhs.govhttps://www.us-cert.gov/ics/advisories/icsa-20-140-01Mitigation, Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.us-cert.gov/ics/advisories/icsa-20-140-01Mitigation, Patch, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:eds_subsystem:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A38919F2-5EA3-4581-9034-C9D09A3CDEB3",
              "versionEndIncluding": "28.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:*",
              "matchCriteriaId": "E52AA077-A130-4CBF-84C8-76E10D94C0E3",
              "versionEndIncluding": "4.11.00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.00.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "11B12B3C-8A2A-474E-8DE3-E666174800A0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.10.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0D6F9C0-CB2A-42FB-B3E2-4E43002C7579",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.11.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEEB8D1D-C0C8-4CC6-A89D-98D788571217",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rsnetworx:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBCDDC69-A4B2-4665-88C8-6B6A337C5CDC",
              "versionEndIncluding": "28.00.00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F9B29F9-ABAD-4E59-9298-528639F394F3",
              "versionEndIncluding": "32.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions."
    },
    {
      "lang": "es",
      "value": "Productos que usan EDS Subsystem: versi\u00f3n 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versi\u00f3n 4.11.00 y anteriores, software RSNetWorx: versi\u00f3n 28.00.00 y anteriores , software Studio 5000 Logix Designer: versi\u00f3n 32 y anteriores), es vulnerable. Se presenta una vulnerabilidad de corrupci\u00f3n de memoria en el algoritmo que coincide con los corchetes en el subsistema EDS. Esto puede permitir a un atacante crear archivos EDS especializados para bloquear el objeto COM EDSParser, conllevando a condiciones de denegaci\u00f3n de servicio."
    }
  ],
  "id": "CVE-2020-12038",
  "lastModified": "2024-11-21T04:59:09.737",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-05-19T22:15:12.013",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-03-03 18:15
Modified
2024-11-21 05:50
Severity ?
Summary
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6755FCF6-4A0C-478A-AEFF-54E35C45149D",
              "versionStartIncluding": "2.10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04C30129-3F03-4486-B181-EBDE29751372",
              "versionEndIncluding": "20",
              "versionStartIncluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C840463-A11F-43A0-AA45-1AC810713AB6",
              "versionStartIncluding": "21.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5370:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F951670-AF4D-4429-8BC1-79BDEF83B2C3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62414E65-73C7-4172-B7BF-F40A66AFBB90",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_1768:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E5F100A-C8A3-49F2-B1D2-411432472B6B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_1769:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A690BC-4D7C-4B83-A9F6-F860445028A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5370:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E12ADAE3-97B1-48BC-BE69-ED75667C1886",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13EE2216-F25F-44AB-A167-4EEA153C8F8D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA25FF8D-51C5-4928-9B90-E4BD1476F50B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5570:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "482E2CD6-D484-486C-92F4-18432D107E30",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:drivelogix_1794-l34:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A75A0FD-C337-4264-B1E4-96701851D6FA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:drivelogix_5560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDAAA77-6964-44FC-9FFB-ECDF71665965",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:drivelogix_5730:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E185C3-17CA-4E3F-863B-9F906C5C59EA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5570:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "321AE938-192A-4342-8608-ADC81F0B6582",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:rockwellautomation:softlogix_5800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDAB7B6D-CCAC-460B-8A88-3397A2397078",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800."
    },
    {
      "lang": "es",
      "value": "Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores, y RSLogix 5000 versiones 16 hasta 20, usan una clave para verificar que los controladores Logix se est\u00e9n comunicando con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580;\u0026#xa0;DriveLogix 5560, 5730, 1794-L34;\u0026#xa0;Compact GuardLogix 5370, 5380;\u0026#xa0;GuardLogix 5570, 5580;\u0026#xa0;SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores y RSLogix 5000: Versiones 16 hasta 20, son vulnerables porque un atacante no autenticado podr\u00eda pasar por alto este mecanismo de comprobaci\u00f3n y autenticarse con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550 , 5560, 5570, 5580;\u0026#xa0;DriveLogix 5560, 5730, 1794-L34;\u0026#xa0;Compact GuardLogix 5370, 5380;\u0026#xa0;GuardLogix 5570, 5580;\u0026#xa0;SoftLogix 5800"
    }
  ],
  "id": "CVE-2021-22681",
  "lastModified": "2024-11-21T05:50:28.110",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-03-03T18:15:14.643",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-05-20 03:15
Modified
2024-11-21 04:59
Summary
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
References
ics-cert@hq.dhs.govhttps://www.us-cert.gov/ics/advisories/icsa-20-140-01Mitigation, Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.us-cert.gov/ics/advisories/icsa-20-140-01Mitigation, Patch, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:eds_subsystem:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A38919F2-5EA3-4581-9034-C9D09A3CDEB3",
              "versionEndIncluding": "28.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:*",
              "matchCriteriaId": "E52AA077-A130-4CBF-84C8-76E10D94C0E3",
              "versionEndIncluding": "4.11.00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.00.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "11B12B3C-8A2A-474E-8DE3-E666174800A0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.10.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0D6F9C0-CB2A-42FB-B3E2-4E43002C7579",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.11.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEEB8D1D-C0C8-4CC6-A89D-98D788571217",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rsnetworx:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBCDDC69-A4B2-4665-88C8-6B6A337C5CDC",
              "versionEndIncluding": "28.00.00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F9B29F9-ABAD-4E59-9298-528639F394F3",
              "versionEndIncluding": "32.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions."
    },
    {
      "lang": "es",
      "value": "Productos que usan EDS Subsystem: versi\u00f3n 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versi\u00f3n 4.11.00 y anteriores, software RSNetWorx: versi\u00f3n 28.00.00 y anteriores, software Studio 5000 Logix Designer: versi\u00f3n 32 y anteriores) son vulnerables. El EDS Subsystem no proporciona un saneamiento de entrada adecuado, lo que puede permitir a un atacante dise\u00f1ar archivos EDS especializados para inyectar consultas SQL y manipular la base de datos que almacena los archivos EDS. Esto puede conllevar a condiciones de denegaci\u00f3n de servicio."
    }
  ],
  "id": "CVE-2020-12034",
  "lastModified": "2024-11-21T04:59:09.277",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-05-20T03:15:09.960",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-140-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}