CVE-2020-12025 (GCVE-0-2020-12025)
Vulnerability from cvelistv5
Published
2020-07-14 12:44
Modified
2024-08-04 11:48
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-611 - IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE
Summary
Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 |
Version: Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:48:57.991Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02" } ] } ], "datePublic": "2020-07-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-611", "description": "IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T12:44:30", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-12025", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02", "version": { "version_data": [ { "version_value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-12025", "datePublished": "2020-07-14T12:44:30", "dateReserved": "2020-04-21T00:00:00", "dateUpdated": "2024-08-04T11:48:57.991Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-12025\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-07-14T13:15:11.343\",\"lastModified\":\"2024-11-21T04:59:08.237\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program.\"},{\"lang\":\"es\",\"value\":\"Rockwell Automation Logix Designer Studio 5000 Versiones 32.00, 32.01 y 32.02, es susceptible a una vulnerabilidad de tipo xml external entity (XXE), que puede permitir a un atacante visualizar nombres de host u otros recursos del programa\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:32.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4083E3F1-AD2E-4A0B-9B19-67D471C25FC6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:32.01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53B85CCF-1DD1-4073-9374-F32463416C70\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:32.02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"16E1A28F-F6F7-4B6B-B0B6-7A3085CB31E2\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.