CVE-2012-4695 (GCVE-0-2012-4695)
Vulnerability from cvelistv5
Published
2013-04-18 01:00
Modified
2024-09-16 20:43
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage) via a zero-byte UDP packet that is not properly handled by Logger.dll.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T20:42:55.127Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage) via a zero-byte UDP packet that is not properly handled by Logger.dll." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-04-18T01:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-4695", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage) via a zero-byte UDP packet that is not properly handled by Logger.dll." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf", "refsource": "MISC", "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf" }, { "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599", "refsource": "CONFIRM", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-4695", "datePublished": "2013-04-18T01:00:00Z", "dateReserved": "2012-08-28T00:00:00Z", "dateUpdated": "2024-09-16T20:43:24.359Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2012-4695\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-04-18T02:25:36.913\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage) via a zero-byte UDP packet that is not properly handled by Logger.dll.\"},{\"lang\":\"es\",\"value\":\"LogReceiver.exe de Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, SR2-CPR9, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1 y CPR9-SR6 permite a atacantes remotos provocar una denegaci\u00f3n de servicio (interrupci\u00f3n del servicio) a trav\u00e9s de un paquete UDP de cero bytes que no se maneja adecuadamente por Logger.dll.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:C\",\"baseScore\":7.1,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E175F9C-864E-47A9-B86F-68CB8E62273E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr1:*:*:*:*:*:*\",\"matchCriteriaId\":\"35E07706-2CFF-4E29-9682-AF627181789C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr2:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C43F1DB-8C69-4568-BA2B-9524727DBA5D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr3:*:*:*:*:*:*\",\"matchCriteriaId\":\"A49F11FD-8C9B-4704-BC2D-CCF31F818A44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr4:*:*:*:*:*:*\",\"matchCriteriaId\":\"02C21A5D-AA9A-4845-81AB-8C884F1C419A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr5:*:*:*:*:*:*\",\"matchCriteriaId\":\"60D852E9-0438-489B-9B36-D8768F659770\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr5.1:*:*:*:*:*:*\",\"matchCriteriaId\":\"23C9AD76-9094-44BB-8B57-9631FEAE3CB3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:rockwellautomation:rslinx_enterprise:cpr9:sr6:*:*:*:*:*:*\",\"matchCriteriaId\":\"670C0268-B3B3-4216-A9B1-AC9423B19DD6\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://ics-cert.us-cert.gov/pdf/ICSA-13-095-02.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…