CVE-2013-0657 (GCVE-0-2013-0657)
Vulnerability from cvelistv5
Published
2013-01-21 16:00
Modified
2024-08-06 14:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T14:33:05.720Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf" }, { "name": "45218", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "https://www.exploit-db.com/exploits/45218/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-01-18T00:00:00", "descriptions": [ { "lang": "en", "value": "Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-08-21T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf" }, { "name": "45218", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "https://www.exploit-db.com/exploits/45218/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2013-0657", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf" }, { "name": "45218", "refsource": "EXPLOIT-DB", "url": "https://www.exploit-db.com/exploits/45218/" }, { "name": "http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip", "refsource": "CONFIRM", "url": "http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip" }, { "name": "http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip", "refsource": "CONFIRM", "url": "http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2013-0657", "datePublished": "2013-01-21T16:00:00", "dateReserved": "2012-12-19T00:00:00", "dateUpdated": "2024-08-06T14:33:05.720Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2013-0657\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-01-21T16:55:01.947\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer basado en pila en Scheneider Electric Interactive Graphical SCADA System (IGSS) v10 y anteriores que permite a atacantes remotos ejecutar c\u00f3digo arbitrario enviando datos por el puerto TCP 12397 que no cumplen con el protocolo.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"10.0\",\"matchCriteriaId\":\"09179F1F-9640-488B-BA2E-138804055F4F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8C7660B-F963-44F7-8E49-8ADF9D04CBCB\"}]}]}],\"references\":[{\"url\":\"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\"]},{\"url\":\"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"US Government Resource\"]},{\"url\":\"https://www.exploit-db.com/exploits/45218/\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://igss.schneider-electric.com/igss/igssupdates/v100/progupdatesv100.zip\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\"]},{\"url\":\"http://igss.schneider-electric.com/igss/igssupdates/v90/progupdatesv90.zip\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-13-018-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"US Government Resource\"]},{\"url\":\"https://www.exploit-db.com/exploits/45218/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…