CVE-2017-14470 (GCVE-0-2017-14470)
Vulnerability from cvelistv5
Published
2018-04-05 21:00
Modified
2024-09-17 01:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- denial of service
Summary
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Talos | Allen Bradley |
Version: Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T19:27:40.657Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Allen Bradley", "vendor": "Talos", "versions": [ { "status": "affected", "version": "Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15" } ] } ], "datePublic": "2018-03-28T00:00:00", "descriptions": [ { "lang": "en", "value": "An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "denial of service", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T18:21:20", "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "shortName": "talos" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "talos-cna@cisco.com", "DATE_PUBLIC": "2018-03-28T00:00:00", "ID": "CVE-2017-14470", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Allen Bradley", "version": { "version_data": [ { "version_value": "Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15" } ] } } ] }, "vendor_name": "Talos" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix." } ] }, "impact": { "cvss": { "baseScore": 10, "baseSeverity": null, "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "denial of service" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443", "refsource": "MISC", "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443" } ] } } } }, "cveMetadata": { "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b", "assignerShortName": "talos", "cveId": "CVE-2017-14470", "datePublished": "2018-04-05T21:00:00Z", "dateReserved": "2017-09-13T00:00:00", "dateUpdated": "2024-09-17T01:06:52.162Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-14470\",\"sourceIdentifier\":\"talos-cna@cisco.com\",\"published\":\"2018-04-05T21:29:01.037\",\"lastModified\":\"2024-11-21T03:12:51.443\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de control de acceso explotable en la funcionalidad de permisos de archivos de datos, programas y funciones de Allen Bradley Micrologix 1400 Serie B FRN 21.2 y anteriores. Un paquete especialmente dise\u00f1ado puede causar una operaci\u00f3n de lectura o escritura que resulte en la divulgaci\u00f3n de informaci\u00f3n sensible, la modificaci\u00f3n de la configuraci\u00f3n o la modificaci\u00f3n de la l\u00f3gica de escalera. Un atacante puede enviar paquetes no autentificados para activar esta vulnerabilidad. Estado del interruptor de llave requerido: REMOTE o PROG o RUN Descripci\u00f3n: El valor 0xffffff se considera NaN para el tipo de datos Float. Cuando se establece un flotador con este valor y se utiliza en el PLC, se desencadena un fallo. NOTA: Esto no es posible a trav\u00e9s de RSLogix\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"talos-cna@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:micrologix_1400_b_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.2\",\"matchCriteriaId\":\"E3CFD00A-A73C-46AA-B6BD-93C44FBCC98F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:micrologix_1400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"196EA0BE-FDF3-46BE-B3DA-5F49208C5D80\"}]}]}],\"references\":[{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443\",\"source\":\"talos-cna@cisco.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2017-0443\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…