CVE-2019-3706 (GCVE-0-2019-3706)
Vulnerability from cvelistv5
Published
2019-04-26 18:22
Modified
2024-09-17 00:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Web Interface Authentication Bypass Vulnerability
Summary
Dell EMC iDRAC9 versions prior to 3.24.24.24, 3.21.26.22, 3.22.22.22 and 3.21.25.22 contain an authentication bypass vulnerability. A remote attacker may potentially exploit this vulnerability to bypass authentication and gain access to the system by sending specially crafted data to the iDRAC web interface.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T19:19:17.489Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "iDRAC", "vendor": "Dell EMC", "versions": [ { "lessThan": "3.24.24.24", "status": "affected", "version": "3.24.24.24", "versionType": "custom" }, { "lessThan": "3.21.26.22", "status": "affected", "version": "3.21.26.22", "versionType": "custom" }, { "lessThan": "3.22.22.22", "status": "affected", "version": "3.22.22.22", "versionType": "custom" }, { "lessThan": "3.21.25.22", "status": "affected", "version": "3.21.25.22", "versionType": "custom" } ] } ], "datePublic": "2019-04-25T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC iDRAC9 versions prior to 3.24.24.24, 3.21.26.22, 3.22.22.22 and 3.21.25.22 contain an authentication bypass vulnerability. A remote attacker may potentially exploit this vulnerability to bypass authentication and gain access to the system by sending specially crafted data to the iDRAC web interface." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "Web Interface Authentication Bypass Vulnerability", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-26T18:22:09", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en" } ], "source": { "discovery": "UNKNOWN" }, "title": "Web Interface Authentication Bypass Vulnerability", "x_generator": { "engine": "Vulnogram 0.0.6" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security_alert@emc.com", "DATE_PUBLIC": "2019-04-25T23:00:00.000Z", "ID": "CVE-2019-3706", "STATE": "PUBLIC", "TITLE": "Web Interface Authentication Bypass Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "iDRAC", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.24.24.24", "version_value": "3.24.24.24" }, { "version_affected": "\u003c", "version_name": "3.21.26.22", "version_value": "3.21.26.22" }, { "version_affected": "\u003c", "version_name": "3.22.22.22", "version_value": "3.22.22.22" }, { "version_affected": "\u003c", "version_name": "3.21.25.22", "version_value": "3.21.25.22" } ] } } ] }, "vendor_name": "Dell EMC" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC iDRAC9 versions prior to 3.24.24.24, 3.21.26.22, 3.22.22.22 and 3.21.25.22 contain an authentication bypass vulnerability. A remote attacker may potentially exploit this vulnerability to bypass authentication and gain access to the system by sending specially crafted data to the iDRAC web interface." } ] }, "generator": { "engine": "Vulnogram 0.0.6" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Web Interface Authentication Bypass Vulnerability" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en", "refsource": "MISC", "url": "https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2019-3706", "datePublished": "2019-04-26T18:22:09.012297Z", "dateReserved": "2019-01-03T00:00:00", "dateUpdated": "2024-09-17T00:26:34.078Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-3706\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2019-04-26T19:29:00.587\",\"lastModified\":\"2024-11-21T04:42:22.360\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC iDRAC9 versions prior to 3.24.24.24, 3.21.26.22, 3.22.22.22 and 3.21.25.22 contain an authentication bypass vulnerability. A remote attacker may potentially exploit this vulnerability to bypass authentication and gain access to the system by sending specially crafted data to the iDRAC web interface.\"},{\"lang\":\"es\",\"value\":\"Dell EMC iDRAC9 versiones anteriores a 3.24.24.24.24, 3.21.26.22, 3.22.22.22 y 3.21.25.22 contienen una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n. Un atacante remoto puede explotar esta vulnerabilidad para evitar la autenticaci\u00f3n y obtener acceso al sistema enviando datos especialmente dise\u00f1ados a la interfaz web de iDRAC.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:idrac9_firmware:3.20.21.20:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5858C3AA-9B29-4C80-B44A-DABEB2855452\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:idrac9_firmware:3.21.24.22:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2276C7F7-8879-4703-9BCA-01F671211635\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:idrac9_firmware:3.23.23.23:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"526D315E-1BB1-4FF8-9D93-01ABB2D54A08\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/article/us/en/04/sln316930/dsa-2019-028-dell-emc-idrac-multiple-vulnerabilities?lang=en\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…