CVE-2019-6957 (GCVE-0-2019-6957)
Vulnerability from cvelistv5
Published
2019-05-29 18:55
Modified
2024-09-16 16:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:31:04.396Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2019-04-04T00:00:00", "descriptions": [ { "lang": "en", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-05-29T18:55:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ], "solutions": [ { "lang": "en", "value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory." } ], "source": { "discovery": "UNKNOWN" }, "title": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems", "x_generator": { "engine": "Vulnogram 0.0.6" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2019-04-04T22:00:00.000Z", "ID": "CVE-2019-6957", "STATE": "PUBLIC", "TITLE": "Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface." } ] }, "generator": { "engine": "Vulnogram 0.0.6" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf", "refsource": "CONFIRM", "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf" } ] }, "solution": [ { "lang": "en", "value": "In cases where a software update is not possible, a reduction in the system\u2019s network exposure is advised. Internet-accessible installations should be firewalled, whilst additional steps like network isolation by VLAN, IP filtering features of the devices and other technologies should be used to decrease the exposure of vulnerable systems. In addition the firewall on the hosts shall be activated and set according to BVMS and BIS configuration manual. \n\nFor further informatation please check the published security advisory." } ], "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-6957", "datePublished": "2019-05-29T18:55:20.387906Z", "dateReserved": "2019-01-25T00:00:00", "dateUpdated": "2024-09-16T16:38:39.411Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-6957\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-05-29T19:29:00.657\",\"lastModified\":\"2024-11-21T04:47:18.127\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de seguridad encontrada recientemente impacta a todas las versiones 9.0 y anteriores de Bosch Video Management System (BVMS), DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). La vulnerabilidad potencialmente permite la ejecuci\u00f3n no autorizada de c\u00f3digo en el sistema por medio de la interfaz de red.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:access_professional_edition:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndIncluding\":\"3.7\",\"matchCriteriaId\":\"3B5A626A-B735-4E0B-8BAC-0A26A02D6599\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:bosch_video_client:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.7.6.079\",\"matchCriteriaId\":\"EFBF448F-005B-48FF-B796-DBC8EAA35323\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"9.0\",\"matchCriteriaId\":\"0B9DD276-15C0-4942-8899-553F7C190320\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2.2\",\"versionEndIncluding\":\"4.4\",\"matchCriteriaId\":\"D92BA2E1-8554-4F13-938D-855BC33A59C9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:4.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8585CAE6-8A82-4338-A510-BB1798AC0BE3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:4.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05B6AD6C-8FCC-473C-9D9A-91EA6C9A8E3E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:building_integration_system:4.6.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8E219B63-2423-4D01-BDA9-8128B5E0DC24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.10\",\"matchCriteriaId\":\"4100A710-A356-4D54-BADE-F6C16947C3F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.71.0032\",\"matchCriteriaId\":\"526B56A8-3106-44C1-8C77-B22995A98C86\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.81\",\"versionEndExcluding\":\"3.81.0048\",\"matchCriteriaId\":\"31523A17-95B3-42D6-B176-1814A91239C9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:video_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.32.0099\",\"matchCriteriaId\":\"F421BFB6-5448-4B86-AEB6-062682F56C10\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.43.0023\",\"matchCriteriaId\":\"DAA61FF3-D717-4A33-B175-E418B11A0BEE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bosch:video_streaming_gateway:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.45\",\"versionEndExcluding\":\"6.45.0008\",\"matchCriteriaId\":\"8CD3166A-2B9C-4641-803C-BC4EBEF035F1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_2000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"0380.037\",\"matchCriteriaId\":\"EC039957-2F53-4080-AB7B-1E2AA4F81790\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_2000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BC890021-B200-4743-AB51-03BDC9CB1351\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_3000_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FAE1D3ED-FE23-4F3B-AE75-2FFBDEF5FDAF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABB194FD-9D50-4420-925F-48E4B2D0C2E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_5000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"038.037\",\"matchCriteriaId\":\"E0062D5B-DF47-47AB-A6E7-B00BEA2FBA1E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_5000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EFAEE79-2B7C-4F74-B663-F49F2606AF41\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:dip_7000_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7731276E-38B9-4B01-B4A3-092A49150B9A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_7000:gen1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8FDECC6-46D7-4EAF-9CBC-06D2F18AADA5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:dip_7000:gen2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ED2FF548-939C-4F10-A3E7-02DF342A35B0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.8.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA449D4D-8AF0-4792-A9CA-8195A4E0082B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE6EFC6A-351D-4571-A1F7-1E6AC0B77B22\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6B97D59-8692-449F-BA59-C2C2F3E0FDDB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:access_easy_controller_firmware:2.1.9.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A3C2E4AA-B871-4B0B-8BD0-8D5440BE8144\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:access_easy_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"50324AEF-BF89-4AAC-B467-FCF87796AB01\"}]}]}],\"references\":[{\"url\":\"https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…