Summary
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
ABB | 800xA for MOD300 |
Version: all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:03:46.099Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "800xA for MOD300", "vendor": "ABB", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-264", "description": "CWE-264 Permissions, Privileges, and Access Controls", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-29T01:59:04", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "ID": "CVE-2020-8485", "STATE": "PUBLIC", "TITLE": "ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "800xA for MOD300", "version": { "version_data": [ { "version_affected": "undefined", "version_value": "all versions" } ] } } ] }, "vendor_name": "ABB" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-264 Permissions, Privileges, and Access Controls" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2020-8485", "datePublished": "2020-04-29T01:59:04", "dateReserved": "2020-01-30T00:00:00", "dateUpdated": "2024-08-04T10:03:46.099Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-8485\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2020-04-29T02:15:12.203\",\"lastModified\":\"2024-11-21T05:38:55.647\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.\"},{\"lang\":\"es\",\"value\":\"Una protecci\u00f3n insuficiente de las funciones de comunicaci\u00f3n entre procesos en ABB System 800xA para MOD 300 (todas las versiones publicadas), permite a un atacante autentificado en el sistema local inyectar datos, permitiendo leer y escribir en los controladores o causar que los procesos de Windows se bloqueen.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa:*:*:*:*:*:*:mod_300:*\",\"matchCriteriaId\":\"F0A34B66-5DA2-4BDD-A5E0-2BF15D58354C\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…