CVE-2021-21579 (GCVE-0-2021-21579)
Vulnerability from cvelistv5
Published
2021-08-03 15:30
Modified
2024-09-16 20:32
CWE
  • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
Summary
Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links.
Impacted products
Vendor Product Version
Dell Integrated Dell Remote Access Controller (iDRAC) Version: unspecified   < 4.40.40.00
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:23.474Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000189193"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Integrated Dell Remote Access Controller (iDRAC)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.40.40.00",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-06-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-03T15:30:21",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000189193"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-06-30",
          "ID": "CVE-2021-21579",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Integrated Dell Remote Access Controller (iDRAC)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.40.40.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000189193",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000189193"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21579",
    "datePublished": "2021-08-03T15:30:21.853844Z",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-09-16T20:32:58.837Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-21579\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-08-03T16:15:08.047\",\"lastModified\":\"2024-11-21T05:48:38.657\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC iDRAC9 versions prior to 4.40.40.00 contain an open redirect vulnerability. A remote unauthenticated attacker may exploit this vulnerability to redirect users to arbitrary web URLs by tricking the victim users to click on maliciously crafted links.\"},{\"lang\":\"es\",\"value\":\"Dell EMC iDRAC9 versiones anteriores a 4.40.40.00, contienen una vulnerabilidad de redireccionamiento abierto. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para redirigir a usuarios a URLs web arbitrarias al enga\u00f1ar a usuarios v\u00edctimas para que hagan clic enlaces maliciosamente dise\u00f1ados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_idrac9_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.40.40.00\",\"matchCriteriaId\":\"8677A5D5-756F-411F-B0D7-2E06105F3B56\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000189193\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000189193\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…