CVE-2021-22731 (GCVE-0-2021-22731)
Vulnerability from cvelistv5
Published
2021-05-26 19:19
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
Summary
Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.
References
► | URL | Tags | |
---|---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior |
Version: Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:06.977Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior ", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior" } ] } ], "descriptions": [ { "lang": "en", "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-640", "description": "CWE-640: Weak Password Recovery Mechanism for Forgotten Password", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-26T19:19:23", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22731", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior ", "version": { "version_data": [ { "version_value": "Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-640: Weak Password Recovery Mechanism for Forgotten Password" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-01", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22731", "datePublished": "2021-05-26T19:19:23", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:06.977Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-22731\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-05-26T20:15:08.927\",\"lastModified\":\"2024-11-21T05:50:33.060\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad del Mecanismo de Recuperaci\u00f3n de Contrase\u00f1a d\u00e9bil para Contrase\u00f1a Olvidada en Modicon Managed Switch MCSESM* y MCSESP* versiones V8.21 y anteriores, lo que podr\u00eda causar un cambio de contrase\u00f1a no autorizada mediante protocolo HTTP / HTTPS cuando la informaci\u00f3n b\u00e1sica del usuario es conocida por un atacante remoto\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-640\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesp083f23g0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"DE56838D-64AB-46F1-BD5F-1A758FFEA86F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesp083f23g0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"76189346-40F5-4AD0-BF60-4ECD6FA3F5C4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesp083f23g0t_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"6EE8E5A5-31D2-4551-BF04-6CF866C72E48\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesp083f23g0t:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1062C777-E64F-4DB7-B74B-87AB50DC00A9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm043f23f0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"3CB244B6-6C64-459C-8829-441CA612AE87\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm043f23f0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0A1CFDBB-21EF-4627-B2A2-23BF4AF371B3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm053f1cu0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"2DAFBA5A-B9D1-4F15-AF1A-5B0D63A2E66F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm053f1cu0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"902BE29F-EBC8-4148-B963-C18B97A01B48\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm063f2cu0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"5BA42014-91C2-4939-A227-8A35D49C9046\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm063f2cu0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EDA5F865-A2D4-4EC5-A8BE-ED7D6FE04594\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm053f1cs0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"8DF47338-DCD8-4446-83A8-3BF3ED31E631\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm053f1cs0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D0B52D7-CD51-4193-8671-174551E5DABC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm063f2cs0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"5C47F14D-8F92-41C6-AC3D-DE337EBC2329\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm063f2cs0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5CFEBC9-3269-45BF-83C9-3E5C98D377B1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm083f23f0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"C2753ECF-8BE6-4D01-BCA6-08670D029B64\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm083f23f0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"92C8921B-5F6E-4760-B46B-49A652CA3A75\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm103f2cu0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"B731B68D-5830-4974-A8E7-A90A6BD9F922\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm103f2cu0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC392C4A-0CD6-442F-BC05-0AB70999D0C2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm083f23f0h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"4430F231-4759-403E-8DD1-3EB92F56B5D1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm083f23f0h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B869FB07-9FEE-45E6-B48D-9DFF7D773DD3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm103f2cu0h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"D9D00737-1BE3-4CDE-9910-6CBA5F4846BD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm103f2cu0h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DFEBD24-D136-4DD7-B834-008FD707AFBE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm103f2cs0h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"37BAF0C6-50C8-43FB-A80A-56700BE1063C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm103f2cs0h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"468C59AC-C017-4B54-B400-769D5A7B0711\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm123f2lg0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"B38FA7F5-DC67-4F9B-B2B1-A1D3F42C30A7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm123f2lg0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"833B82C6-C621-4E41-A80F-A4AB806AB07A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm093f1cu0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"7DFDE537-2D8F-4F2F-B641-102E60663C84\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm093f1cu0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C09DCE5-2128-4A17-9187-AC0FCE111446\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm093f1cs0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"78CCA9C0-277A-4AE2-9FDD-6992F1DC7492\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm093f1cs0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"375DDEF7-9AAF-4973-B72C-BFAB4CF46F5B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:mcsesm103f2cs0_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.22\",\"matchCriteriaId\":\"FD204C41-8EEA-4847-9712-AA5BBEA5CDEF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:mcsesm103f2cs0:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF26B84A-0412-4C7A-B96C-9220E21C7A65\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.