CVE-2021-38123 (GCVE-0-2021-38123)
Vulnerability from cvelistv5
Published
2021-09-07 16:48
Modified
2024-08-04 01:30
Severity ?
CWE
  • Open Redirect.
Summary
Open Redirect vulnerability in Micro Focus Network Automation, affecting Network Automation versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05. The vulnerability could allow redirect users to malicious websites after authentication.
Impacted products
Vendor Product Version
n/a Network Automation. Version: Network Automation (NA) versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:30:09.045Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://portal.microfocus.com/s/article/KM000001673"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Network Automation.",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Network Automation (NA) versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Open Redirect vulnerability in Micro Focus Network Automation, affecting Network Automation versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05. The vulnerability could allow redirect users to malicious websites after authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Open Redirect.",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-07T16:48:24",
        "orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
        "shortName": "microfocus"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://portal.microfocus.com/s/article/KM000001673"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@microfocus.com",
          "ID": "CVE-2021-38123",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Network Automation.",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Network Automation (NA) versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Open Redirect vulnerability in Micro Focus Network Automation, affecting Network Automation versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05. The vulnerability could allow redirect users to malicious websites after authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Open Redirect."
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://portal.microfocus.com/s/article/KM000001673",
              "refsource": "MISC",
              "url": "https://portal.microfocus.com/s/article/KM000001673"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
    "assignerShortName": "microfocus",
    "cveId": "CVE-2021-38123",
    "datePublished": "2021-09-07T16:48:24",
    "dateReserved": "2021-08-04T00:00:00",
    "dateUpdated": "2024-08-04T01:30:09.045Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-38123\",\"sourceIdentifier\":\"security@opentext.com\",\"published\":\"2021-09-07T17:15:07.280\",\"lastModified\":\"2024-11-21T06:16:25.920\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Open Redirect vulnerability in Micro Focus Network Automation, affecting Network Automation versions 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05. The vulnerability could allow redirect users to malicious websites after authentication.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de redirecci\u00f3n abierta en Micro Focus Network Automation, que afecta a las versiones 10.4x, 10.5x, 2018.05, 2018.11, 2019.05, 2020.02, 2020.08, 2020.11, 2021.05 de Network Automation. La vulnerabilidad podr\u00eda permitir redirigir a usuarios a sitios web maliciosos despu\u00e9s de la autenticaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:10.40:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42545A63-B5CA-4668-8AD0-4D341AEBE531\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:10.50:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EBC2D47A-E969-4E42-95DB-34859638DEA0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2018.05:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0BE62C5B-6464-4096-9324-5A9CCCFFECAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2018.11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6814B971-E024-4096-86C3-8D4EA13FBE39\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2019.05:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31890072-DB70-452B-BF01-41F8E46147CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2020.02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BBF1A50-1ABB-40B0-90D0-B5A5E344B219\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2020.08:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4D2BA93-BD51-4D66-95EE-A90F7221B7EA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2020.11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8E96A589-803F-4FA4-98C5-DEBBDF3FA589\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:microfocus:network_automation:2021.05:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9F1E6FF-D0BD-4558-B8B3-391F6A8C6A52\"}]}]}],\"references\":[{\"url\":\"https://portal.microfocus.com/s/article/KM000001673\",\"source\":\"security@opentext.com\"},{\"url\":\"https://portal.microfocus.com/s/article/KM000001673\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…