CVE-2022-33178 (GCVE-0-2022-33178)
Vulnerability from cvelistv5
Published
2022-10-25 00:00
Modified
2025-05-07 20:40
CWE
  • Improper input validation
Summary
A vulnerability in the radius authentication system of Brocade Fabric OS before Brocade Fabric OS 9.0 could allow a remote attacker to execute arbitrary code on the Brocade switch.
Impacted products
Vendor Product Version
n/a Brocade Fabric OS Version: Brocade Fabric OS versions before Brocade Fabric OS 9.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:01:20.167Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2077"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20230127-0003/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-33178",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-07T20:40:12.136761Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-20",
                "description": "CWE-20 Improper Input Validation",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-07T20:40:36.059Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Brocade Fabric OS",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Brocade Fabric OS versions before Brocade Fabric OS 9.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the radius authentication system of Brocade Fabric OS before Brocade Fabric OS 9.0 could allow a remote attacker to execute arbitrary code on the Brocade switch."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper input validation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-27T00:00:00.000Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2077"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20230127-0003/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2022-33178",
    "datePublished": "2022-10-25T00:00:00.000Z",
    "dateReserved": "2022-06-13T00:00:00.000Z",
    "dateUpdated": "2025-05-07T20:40:36.059Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-33178\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2022-10-25T21:15:46.047\",\"lastModified\":\"2025-05-07T21:15:54.117\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the radius authentication system of Brocade Fabric OS before Brocade Fabric OS 9.0 could allow a remote attacker to execute arbitrary code on the Brocade switch.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en el sistema de autenticaci\u00f3n radius de Brocade Fabric OS versiones anteriores a Brocade Fabric OS 9.0, podr\u00eda permitir a un atacante remoto ejecutar c\u00f3digo arbitrario en el conmutador Brocade\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.0.0\",\"matchCriteriaId\":\"28897387-F3CA-441E-8290-E32C1BBFEED8\"}]}]}],\"references\":[{\"url\":\"https://security.netapp.com/advisory/ntap-20230127-0003/\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2077\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20230127-0003/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2077\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2077\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230127-0003/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T08:01:20.167Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-33178\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-07T20:40:12.136761Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-07T20:40:26.248Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"Brocade Fabric OS\", \"versions\": [{\"status\": \"affected\", \"version\": \"Brocade Fabric OS versions before Brocade Fabric OS 9.0\"}]}], \"references\": [{\"url\": \"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2022-2077\"}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230127-0003/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the radius authentication system of Brocade Fabric OS before Brocade Fabric OS 9.0 could allow a remote attacker to execute arbitrary code on the Brocade switch.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Improper input validation\"}]}], \"providerMetadata\": {\"orgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"shortName\": \"brocade\", \"dateUpdated\": \"2023-01-27T00:00:00.000Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-33178\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-07T20:40:36.059Z\", \"dateReserved\": \"2022-06-13T00:00:00.000Z\", \"assignerOrgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"datePublished\": \"2022-10-25T00:00:00.000Z\", \"assignerShortName\": \"brocade\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…