CVE-2022-3461 (GCVE-0-2022-3461)
Vulnerability from cvelistv5
Published
2022-11-15 10:59
Modified
2025-04-29 20:13
CWE
  • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Summary
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:07:06.698Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2022-048/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3461",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-29T20:12:58.841065Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-29T20:13:09.642Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Config+",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "1.89",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "1.89",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PC Worx Express",
          "vendor": "PHOENIX CONTACT",
          "versions": [
            {
              "lessThanOrEqual": "1.89",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "This vulnerability was discovered by Michael Heinzl"
        }
      ],
      "datePublic": "2022-11-08T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities."
            }
          ],
          "value": "In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-15T10:59:53.718Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2022-048/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to Automation Worx Software Suite \u0026gt; 1.89"
            }
          ],
          "value": "Upgrade to Automation Worx Software Suite \u003e 1.89"
        }
      ],
      "source": {
        "advisory": "VDE-2022-048",
        "defect": [
          "CERT@VDE64164"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Buffer Overflow in PHOENIX CONTACT Automationworx Software Suite",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-3461",
    "datePublished": "2022-11-15T10:59:53.718Z",
    "dateReserved": "2022-10-12T05:45:11.921Z",
    "dateUpdated": "2025-04-29T20:13:09.642Z",
    "requesterUserId": "a1e5283b-8f0d-401e-98b2-bc6219c0e8d1",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-3461\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2022-11-15T11:15:10.917\",\"lastModified\":\"2024-11-21T07:19:34.340\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\"},{\"lang\":\"es\",\"value\":\"En PHOENIX CONTACT Automationworx Software Suite hasta la versi\u00f3n 1.89, los archivos PC Worx o Config+ manipulados pod\u00edan provocar un desbordamiento del b\u00fafer de pila y una violaci\u00f3n del acceso de lectura. La disponibilidad, la integridad o la confidencialidad de una estaci\u00f3n de trabajo de programaci\u00f3n de aplicaciones podr\u00edan verse comprometidas por ataques que utilicen estas vulnerabilidades.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:phoenixcontact:automationworx_software_suite:1.89:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D16C5674-97DC-477C-98D8-A93B47B625BB\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-048/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://cert.vde.com/en/advisories/VDE-2022-048/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-048/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T01:07:06.698Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-3461\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-29T20:12:58.841065Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-29T20:13:02.580Z\"}}], \"cna\": {\"title\": \"Buffer Overflow in PHOENIX CONTACT Automationworx Software Suite\", \"source\": {\"defect\": [\"CERT@VDE64164\"], \"advisory\": \"VDE-2022-048\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"This vulnerability was discovered by Michael Heinzl\"}], \"impacts\": [{\"capecId\": \"CAPEC-100\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-100 Overflow Buffers\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"PHOENIX CONTACT\", \"product\": \"Config+\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"1.89\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"PHOENIX CONTACT\", \"product\": \"PC Worx\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"1.89\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"PHOENIX CONTACT\", \"product\": \"PC Worx Express\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"1.89\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to Automation Worx Software Suite \u003e 1.89\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Upgrade to Automation Worx Software Suite \u0026gt; 1.89\", \"base64\": false}]}], \"datePublic\": \"2022-11-08T08:00:00.000Z\", \"references\": [{\"url\": \"https://cert.vde.com/en/advisories/VDE-2022-048/\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2022-11-15T10:59:53.718Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-3461\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-29T20:13:09.642Z\", \"dateReserved\": \"2022-10-12T05:45:11.921Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2022-11-15T10:59:53.718Z\", \"requesterUserId\": \"a1e5283b-8f0d-401e-98b2-bc6219c0e8d1\", \"assignerShortName\": \"CERTVDE\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…