CVE-2016-4784 (GCVE-0-2016-4784)
Vulnerability from cvelistv5
Published
2016-05-31 01:00
Modified
2024-09-17 03:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T00:39:26.113Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "90773", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/90773" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "99471", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/99471" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-07-04T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-03-22T16:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "90773", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/90773" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "99471", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/99471" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2017-07-04T00:00:00", "ID": "CVE-2016-4784", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "90773", "refsource": "BID", "url": "http://www.securityfocus.com/bid/90773" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "99471", "refsource": "BID", "url": "http://www.securityfocus.com/bid/99471" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-4784", "datePublished": "2016-05-31T01:00:00Z", "dateReserved": "2016-05-11T00:00:00", "dateUpdated": "2024-09-17T03:59:26.394Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-4784\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2016-05-31T01:59:12.993\",\"lastModified\":\"2025-04-12T10:46:40.837\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.83; SIPROTEC 7UT686: todas las versiones anteriores a la V 4.01; SIPROTEC 7SD686: todas las versiones anteriores a la V 4.03 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.20. El servidor web integrado (puerto 80/tcp) de los dispositivos afectados podr\u00eda permitir que los atacantes remotos obtengan informaci\u00f3n sensible del dispositivo si obtienen acceso de red.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siprotec_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D6A83974-66CD-409D-A309-568578F44A69\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_7rw80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2883847C-7500-4431-8EB9-0B7B4DABC4FD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_7sd80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"72C34F7E-F579-4830-A5E9-F61F71142153\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_7sj80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF126B3F-B400-43B1-AC08-9458055B7449\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_7sj81:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"73E3AAB3-A15B-4159-B7A2-EA70D216B620\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_7sk80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA7F273D-9E60-45AB-9BBD-434D45FA0608\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_7sk81:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"411C805A-16C5-4430-8F23-2D5E4D5A423E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_4_en100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9D3FF8F1-73E6-4F1E-8222-E9191D6A764E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_model_en100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D7CE743D-D5A1-4E58-A8C8-1DC755286B54\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siprotec_firmware:4.26:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DB48800-BDF6-4BF9-8383-39693568CF67\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/90773\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/99471\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/90773\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/bid/99471\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.