CVE-2017-7902 (GCVE-0-2017-7902)
Vulnerability from cvelistv5
Published
2017-06-30 02:35
Modified
2024-08-05 16:19
Severity ?
CWE
Summary
A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.
References
Impacted products
Vendor Product Version
n/a Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Version: Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:28.546Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038546",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038546"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"
            }
          ]
        }
      ],
      "datePublic": "2017-06-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A \"Reusing a Nonce, Key Pair in Encryption\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-323",
              "description": "CWE-323",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-07T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "1038546",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038546"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7902",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A \"Reusing a Nonce, Key Pair in Encryption\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-323"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1038546",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1038546"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7902",
    "datePublished": "2017-06-30T02:35:00",
    "dateReserved": "2017-04-18T00:00:00",
    "dateUpdated": "2024-08-05T16:19:28.546Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-7902\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-06-30T03:29:00.827\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A \\\"Reusing a Nonce, Key Pair in Encryption\\\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema de \\\"Reusing a Nonce, Key Pair in Encryption\\\" en los controladores de l\u00f3gica programable MicroLogix 1100 de Allen-Bradley  1763-L16AWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1763-L16BBB, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1763-L16BWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; y 1763-L16DWD, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores y Controladores l\u00f3gicos programables Allen-Bradley MicroLogix 1400 1766-L32AWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BWA, Series A y B, versi\u00f3n 16.00 y versiones anteriores; 1766-L32BWAA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BXB, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BXBA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; y 1766-L32AWAA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores. El producto afectado reutiliza nonces, lo que puede permitir que un atacante capture y reproduzca una solicitud v\u00e1lida hasta que se cambie el nonce.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-323\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-330\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"E44D0CCE-EDA7-4DF2-B67B-C59DFAE7F888\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"58E4AB51-E136-4AA3-AFF9-50F240489856\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"6006CE1E-08EC-4AFC-8F35-73B24AA7F08D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"F52398D3-996E-4291-887F-6B8E0AF24AFF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"61603F24-7505-4A9E-BA9E-57C7B5A60A6E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"9558148B-3000-4D83-9AB0-380D7FBB0C9A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"C805AFD6-481C-4A32-9CE8-281F9B793263\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"DC9E1F42-4F17-4EA4-8D0F-30220F560A0E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA98842B-9D09-4C37-AB34-4E9FA566BAD8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"8C8E3AF6-1017-4A18-99CA-854F1022ED66\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"A093AA8B-7DB9-4373-AE8F-F8B879A4BE5E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"25DA9309-964B-4C1C-8B95-9C1CD80DDC74\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"6D51D3F6-ABB3-4FFD-81D5-B3D3C29F0A46\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"DC05C3A1-1042-46AD-83D8-765AF4C9BCD9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"6218A006-1F60-4E29-85CC-7D1BCBD7C734\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"6B863572-CECF-47DF-AF6F-C25F88200DBE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"59BEBB0E-8C6E-4663-9E0C-E755C2EF0041\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"1303D987-4A44-4F33-992E-0C7E683EC7A9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"1E7D8E09-D97D-45FF-9AD0-A9B0A846E600\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"9D9C64FB-A613-4940-86E6-95431B907159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"16.000\",\"matchCriteriaId\":\"B5C50D4A-EB32-4BE4-B9E6-D25494E2EF55\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFF2EF59-F451-490D-A7AF-E66D11493948\"}]}]}],\"references\":[{\"url\":\"http://www.securitytracker.com/id/1038546\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securitytracker.com/id/1038546\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…