A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723.
Impacted products
Vendor Product Version
n/a Cisco Enterprise NFV Infrastructure Software Version: Cisco Enterprise NFV Infrastructure Software
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T03:21:15.223Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection"
          },
          {
            "name": "104208",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104208"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2018-0324",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T14:42:39.386655Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T15:08:27.317Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Enterprise NFV Infrastructure Software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cisco Enterprise NFV Infrastructure Software"
            }
          ]
        }
      ],
      "datePublic": "2018-05-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-05-19T09:57:01",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection"
        },
        {
          "name": "104208",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104208"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2018-0324",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Enterprise NFV Infrastructure Software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cisco Enterprise NFV Infrastructure Software"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection",
              "refsource": "CONFIRM",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection"
            },
            {
              "name": "104208",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104208"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2018-0324",
    "datePublished": "2018-05-17T03:00:00",
    "dateReserved": "2017-11-27T00:00:00",
    "dateUpdated": "2024-11-29T15:08:27.317Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-0324\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2018-05-17T03:29:00.763\",\"lastModified\":\"2024-11-21T03:37:58.800\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de l\u00ednea de comandos de Cisco Enterprise NFV Infrastructure Software podr\u00eda permitir que un atacante local autenticado con altos privilegios realice un ataque de inyecci\u00f3n de comandos. La vulnerabilidad se debe a una validaci\u00f3n de entrada insuficiente de algunos par\u00e1metros de comandos en el analizador sint\u00e1ctico de la interfaz de l\u00ednea de comandos. Un atacante podr\u00eda explotar esta vulnerabilidad invocando un comando espec\u00edfico de la interfaz de l\u00ednea de comandos con par\u00e1metros maliciosos manipulados. Su explotaci\u00f3n con \u00e9xito podr\u00eda permitir que el atacante ejecute comandos arbitrarios con una cuenta de usuario no root al sistema operativo Linux subyacente en el dispositivo afectado. Cisco Bug IDs: CSCvi09723.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:network_functions_virtualization_infrastructure:3.6.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0973CD91-EAA5-4D6B-B93F-3FDB3ACD1FA7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:network_functions_virtualization_infrastructure:3.6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC22342E-9624-49B4-B982-557858C34680\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:network_functions_virtualization_infrastructure:3.7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4BBC296-B394-4B88-B0D3-080FD00FA180\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/104208\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/104208\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180516-nfvis-cli-command-injection\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…