CVE-2018-10624 (GCVE-0-2018-10624)
Vulnerability from cvelistv5
Published
2018-08-01 21:00
Modified
2024-09-17 00:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Summary
In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.
References
► | URL | Tags | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Johnson Controls | Metasys System |
Version: 0 < |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T07:46:46.244Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-212-02" }, { "name": "104937", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104937" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Metasys System", "vendor": "Johnson Controls", "versions": [ { "lessThanOrEqual": "8.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "BCPro (BCM)", "vendor": "Johnson Controls", "versions": [ { "lessThan": "3.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Dan Regalado of Zingbox reported this vulnerability to CISA." } ], "datePublic": "2018-07-31T06:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eIn Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.\u003c/p\u003e" } ], "value": "In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-209", "description": "CWE-209 Generation of Error Message Containing Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-23T00:43:24.083Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-212-02" }, { "name": "104937", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104937" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eJohnson Controls recommends the following mitigations:\u003c/p\u003e\u003cul\u003e\u003cli\u003eThis issue was remediated in Metasys v8.1 (April, 2016). Users should upgrade to the latest product version (9.0). For Metasys information, contact your Metasys field service/sales representative.\u003c/li\u003e\u003cli\u003eThis issue was remediated in the BCPro Workstation in BCPro v3.0 (October, 2017) and mitigated for the BACnet Router and Gateway in BCPro v3.0.2 (June, 2018). Users should upgrade to the latest product versions. For more BCPro information, contact your BCPro sales and support representative.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Johnson Controls recommends the following mitigations:\n\n * This issue was remediated in Metasys v8.1 (April, 2016). Users should upgrade to the latest product version (9.0). For Metasys information, contact your Metasys field service/sales representative.\n * This issue was remediated in the BCPro Workstation in BCPro v3.0 (October, 2017) and mitigated for the BACnet Router and Gateway in BCPro v3.0.2 (June, 2018). Users should upgrade to the latest product versions. For more BCPro information, contact your BCPro sales and support representative." } ], "source": { "discovery": "EXTERNAL" }, "title": "Johnson Controls Metasys and BCPro Generation of Error Message Containing Sensitive Information", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eAdditional information for Johnson Controls:\u003c/p\u003e\u003cul\u003e\u003cli\u003eProduct security contact information, Building Automation System hardening, and security resources are located at our product security website \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.johnsoncontrols.com/buildings/specialty-pages/product-security\"\u003ehttp://www.johnsoncontrols.com/buildings/specialty-pages/product-security\u003c/a\u003e\u003c/li\u003e\u003cli\u003eContact information: Johnson Controls Global Product Security at \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://mailto:productsecurity@jci.com/\"\u003eproductsecurity@jci.com\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Additional information for Johnson Controls:\n\n * Product security contact information, Building Automation System hardening, and security resources are located at our product security website http://www.johnsoncontrols.com/buildings/specialty-pages/product-security http://www.johnsoncontrols.com/buildings/specialty-pages/product-security \n * Contact information: Johnson Controls Global Product Security at productsecurity@jci.com http://mailto:productsecurity@jci.com/" } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-07-31T00:00:00", "ID": "CVE-2018-10624", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Metasys System", "version": { "version_data": [ { "version_value": "Versions 8.0 and prior" } ] } }, { "product_name": "BCPro (BCM)", "version": { "version_data": [ { "version_value": "all versions prior to 3.0.2" } ] } } ] }, "vendor_name": "Johnson Controls" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-212-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-212-02" }, { "name": "104937", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104937" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-10624", "datePublished": "2018-08-01T21:00:00Z", "dateReserved": "2018-05-01T00:00:00", "dateUpdated": "2024-09-17T00:11:43.873Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-10624\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-08-01T21:29:00.217\",\"lastModified\":\"2024-11-21T03:41:41.330\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.\"},{\"lang\":\"es\",\"value\":\"En Johnson Controls Metasys System en versiones 8.0 y anteriores y BCPro (BCM) en todas las versiones anteriores a la 3.0.2, esta vulnerabilidad resulta de un manejo de errores incorrecto en las comunicaciones HTTP con el servidor, lo que podr\u00eda permitir que un atacante obtenga informaci\u00f3n t\u00e9cnica.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":3.3,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.5,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-209\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-388\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:johnsoncontrols:bcpro:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.2\",\"matchCriteriaId\":\"719BA35E-A882-4897-B402-0F111564C3E5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:johnsoncontrols:metasys_system:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.0\",\"matchCriteriaId\":\"41A715BD-F19F-4AF4-A4A7-3A93E0C59AB8\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/104937\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-212-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/104937\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-212-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…