CVE-2019-0142 (GCVE-0-2019-0142)
Vulnerability from cvelistv5
Published
2019-11-14 18:21
Modified
2024-08-04 17:44
Severity ?
CWE
  • Escalation of Privilege
Summary
Insufficient access control in ilp60x64.sys driver for Intel(R) Ethernet 700 Series Controllers before version 1.33.0.0 may allow a privileged user to potentially enable escalation of privilege via local access.
Impacted products
Vendor Product Version
n/a 2019.2 IPU – Intel(R) Ethernet 700 Series Controllers Version: See provided reference
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:44:14.605Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "2019.2 IPU \u2013 Intel(R) Ethernet 700 Series Controllers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "See provided reference"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient access control in ilp60x64.sys driver for Intel(R) Ethernet 700 Series Controllers before version 1.33.0.0 may allow a privileged user to potentially enable escalation of privilege via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Escalation of Privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-14T18:21:32",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "ID": "CVE-2019-0142",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "2019.2 IPU \u2013 Intel(R) Ethernet 700 Series Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "See provided reference"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Insufficient access control in ilp60x64.sys driver for Intel(R) Ethernet 700 Series Controllers before version 1.33.0.0 may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Escalation of Privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html",
              "refsource": "MISC",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2019-0142",
    "datePublished": "2019-11-14T18:21:32",
    "dateReserved": "2018-11-13T00:00:00",
    "dateUpdated": "2024-08-04T17:44:14.605Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-0142\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2019-11-14T19:15:11.987\",\"lastModified\":\"2024-11-21T04:16:19.160\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Insufficient access control in ilp60x64.sys driver for Intel(R) Ethernet 700 Series Controllers before version 1.33.0.0 may allow a privileged user to potentially enable escalation of privilege via local access.\"},{\"lang\":\"es\",\"value\":\"Un control de acceso insuficiente en el controlador ilp60x64.sys para Intel\u00ae Ethernet 700 Series Controllers versiones anteriores a la versi\u00f3n 1.33.0.0, puede habilitar a un usuario privilegiado para permitir una escalada de privilegios por medio de un acceso local.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.5,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:ethernet_controller_x710-tm4_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.33.0.0\",\"matchCriteriaId\":\"12B69900-A251-4B7F-900F-076C8C5EE340\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:intel:ethernet_controller_x710-tm4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"41EEFF5E-3C88-43B3-9894-1B0C73DBA06A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:ethernet_controller_x710-at2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.33.0.0\",\"matchCriteriaId\":\"D579875D-1815-4527-94C4-2F7388BC56FD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:intel:ethernet_controller_x710-at2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8225E56D-74F1-43FC-8696-2F326A264704\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:ethernet_controller_xxv710-am2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.33.0.0\",\"matchCriteriaId\":\"811451A0-0961-4C2A-9BD7-D829C4D54B2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:intel:ethernet_controller_xxv710-am2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C6D2A9E-EE3D-4DEC-948E-58416CD32477\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:ethernet_controller_xxv710-am1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.33.0.0\",\"matchCriteriaId\":\"CA07C275-DC94-4111-8E0B-167DF9658CE7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:intel:ethernet_controller_xxv710-am1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA1817F4-978B-4F88-831F-C6259CE20E83\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:ethernet_controller_x710-bm2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.33.0.0\",\"matchCriteriaId\":\"7013E799-8610-49A7-A3AF-B2860E510B58\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:intel:ethernet_controller_x710-bm2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"91940C69-80BB-43F8-81B5-92AAFCF59CE1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:ethernet_controller_710-bm1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.33.0.0\",\"matchCriteriaId\":\"6CF8B188-91E2-4439-B14A-4AD008CBFD5D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:intel:ethernet_controller_710-bm1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE34AA9F-CBD1-423B-A457-5FB79081540F\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:ethernet_700_series_software:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"24.0\",\"matchCriteriaId\":\"BBE4DA9C-61F5-48CF-A995-CD6F48CD4E6B\"}]}]}],\"references\":[{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00255.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…