CVE-2019-13535 (GCVE-0-2019-13535)
Vulnerability from cvelistv5
Published
2019-11-08 19:45
Modified
2025-05-22 18:39
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
► | Medtronic | Valleylab FT10 Energy Platform (VLFT10GEN) |
Version: 0 < Version: 0 < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T23:57:39.351Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsma-19-311-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Valleylab FT10 Energy Platform (VLFT10GEN)", "vendor": "Medtronic", "versions": [ { "lessThanOrEqual": "2.1.0", "status": "affected", "version": "0", "versionType": "custom" }, { "lessThanOrEqual": "2.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States)", "vendor": "Medtronic", "versions": [ { "lessThanOrEqual": "1.20.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Medtronic reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\nIn Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.\n\n\u003c/p\u003e" } ], "value": "In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-693", "description": "CWE-693", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-22T18:39:28.797Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/valleylab-generator-rfid-vulnerabilities.html" }, { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-19-311-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eA software patch is available now for the affected Valleylab platforms. If you suspect you are in possession of an instrument that is not FDA approved or cleared to be used with Medtronic Valleylab FT10 or LS10, please contact Medtronic or your medical device supplier. If you have concerns about FDA clearance or approval of current or future instruments, please contact your medical device supplier. Please contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/covidien/en-us/support/software.html\"\u003eMedtronic\u003c/a\u003e\u0026nbsp;to obtain the software patch.\u003c/p\u003e\u003cp\u003eMedtronic has released additional patient focused information at the following location:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003ehttps://www.medtronic.com/security\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e" } ], "value": "A software patch is available now for the affected Valleylab platforms. If you suspect you are in possession of an instrument that is not FDA approved or cleared to be used with Medtronic Valleylab FT10 or LS10, please contact Medtronic or your medical device supplier. If you have concerns about FDA clearance or approval of current or future instruments, please contact your medical device supplier. Please contact https://www.medtronic.com/security" } ], "source": { "advisory": "ICSMA-19-311-01", "discovery": "INTERNAL" }, "title": "Medtronic Valleylab FT10 and LS10 Protection Mechanism Failure", "x_generator": { "engine": "Vulnogram 0.2.0" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-13531", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Valleylab FT10 Energy Platform (VLFT10GEN)", "version": { "version_data": [ { "version_value": "version 2.1.0 and lower" }, { "version_value": "version 2.0.3 and lower" } ] } }, { "product_name": "Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States)", "version": { "version_data": [ { "version_value": "version 1.20.2 and lower" } ] } } ] }, "vendor_name": "Medtronic" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER AUTHENTICATION CWE-287" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.us-cert.gov/ics/advisories/icsma-19-311-01", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsma-19-311-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-13535", "datePublished": "2019-11-08T19:45:55", "dateReserved": "2019-07-11T00:00:00", "dateUpdated": "2025-05-22T18:39:28.797Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-13535\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2019-11-08T20:15:10.633\",\"lastModified\":\"2025-05-22T19:15:22.880\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN\u2014not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.\"},{\"lang\":\"es\",\"value\":\"En Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) versi\u00f3n 2.1.0 y versiones inferiores y versi\u00f3n 2.0.3 y versiones inferiores, y Valleylab LS10 Energy Platform (VLLS10GEN \u2014no disponible en los Estados Unidos) versi\u00f3n 1.20.2 y versiones inferiores, el mecanismo de seguridad RFID s\u00ed no aplica protecci\u00f3n de lectura, lo que permite el acceso de lectura total de los datos del mecanismo de seguridad RFID\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":4.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-693\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:medtronic:valleylab_ft10_energy_platform_firmware:2.0.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"89DAFB01-536A-4966-8EAC-5D6CED32CC63\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:medtronic:valleylab_ft10_energy_platform_firmware:2.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31DF6D35-968D-4E8D-A8F5-578B4B9C2BE9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:medtronic:valleylab_ft10_energy_platform:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"164230CB-E2BF-447F-8537-C9401FA0CC09\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:medtronic:valleylab_ls10_energy_platform_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.20.2\",\"matchCriteriaId\":\"EEAE74E9-49AC-4B77-8831-11EA09B204CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:medtronic:valleylab_ls10_energy_platform:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"82294F1E-0BD0-4F55-A732-09B68AA37624\"}]}]}],\"references\":[{\"url\":\"https://global.medtronic.com/xg-en/product-security/security-bulletins/valleylab-generator-rfid-vulnerabilities.html\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-19-311-01\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsma-19-311-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…